Time-resolved luminescent lateral flow assay technology

被引:47
|
作者
Song, Xuedong [1 ]
Knotts, Michael [2 ]
机构
[1] Kimberly Clark Worldwide, Global Sci & Technol, Roswell, GA 30076 USA
[2] Georgia Inst Technol, Georgia Tech Res Inst, Atlanta, GA 30332 USA
关键词
lateral flow immunoassay; time-resolved luminescence; fluorescence; phosphorescence; nanoparticle;
D O I
10.1016/j.aca.2008.08.006
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We here report a detection technology that integrates highly sensitive time-resolved luminescence technique into lateral flow assay platform to achieve excellent detection performance with low cost. We have developed very bright, surface-functionalized and mono-dispersed phosphorescent nanoparticles of long lifetime under ambient conditions. The phosphorescent nanoparticles have been used to conjugate with monoclonal antibody for C-reactive protein (CRP), an inflammatory biomarker. Lateral flow immunoassay devices have been developed using the conjugate for highly sensitive detection of CRP The CRP assay can achieve a detection sensitivity of < 0.2 ng mL(-1) in serum with a linear response from 0.2 to 200 ng mL(-1) CRP. We have also developed a low cost time-resolved luminescence reader for the lateral flow immunoassay (LFIA) devices. The reader does not use expensive band pass filter and still provide very low detection background and high detection sensitivity on solid substrates such as nitrocellulose membranes. The reader can detect less than 2.5 ng phosphorescent particles captured on a nitrocellulose membrane strip with more than three orders of magnitude linear detection dynamic range. The technology should find a number of applications, ranging from clinical diagnostics, detection of chemical and biological warfare agents, to food and environmental monitoring. (c) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:186 / 192
页数:7
相关论文
共 50 条
  • [1] Luminescent Terbium Protein Labels for Time-Resolved Microscopy and Screening
    Rajapakse, Harsha E.
    Reddy, D. Rajasekhar
    Mohandessi, Shabnam
    Butlin, Nathaniel G.
    Miller, Lawrence W.
    ANGEWANDTE CHEMIE-INTERNATIONAL EDITION, 2009, 48 (27) : 4990 - 4992
  • [2] Phosphorescent Nanoparticles and Their Applications for Time-Resolved Luminescent Biological Assays
    Song, Xuedong
    Huang, Lei
    Knotts, Mike
    Wu, Bin
    REPORTERS, MARKERS, DYES, NANOPARTICLES, AND MOLECULAR PROBES FOR BIOMEDICAL APPLICATIONS, 2009, 7190
  • [3] Time-Resolved Luminescence-Based Assay for Thyroglobulin
    Huang, Chih-Ching
    Lin, Tai-Yuan
    Yu, Wen-Shen
    Chen, Chao-Tsen
    Chang, Huan-Tsung
    JOURNAL OF BIOMEDICAL NANOTECHNOLOGY, 2009, 5 (05) : 579 - 585
  • [4] A time-resolved fluorescence lateral flow immunoassay for rapid and quantitative serodiagnosis of Brucella infection in humans
    Lu, Jinhui
    Wu, Ze
    Liu, Bochao
    Wang, Cong
    Wang, Qi
    Zhang, Ling
    Wang, Zhen
    Chen, Chuangfu
    Fu, Yongshui
    Li, Chengyao
    Li, Tingting
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2021, 200
  • [5] A time-resolved fluorescent microsphere-lateral flow immunoassay strip assay with image visual analysis for quantitative detection of Helicobacter pylori in saliva
    Wang, Yilu
    Chen, Qiming
    Wang, Yingying
    Tu, Fangmin
    Chen, Xiaodi
    Li, Junhai
    Liu, Zhanmin
    TALANTA, 2023, 256
  • [6] INORGANIC PHOSPHORS AS NEW LUMINESCENT LABELS FOR IMMUNOCYTOCHEMISTRY AND TIME-RESOLVED MICROSCOPY
    BEVERLOO, HB
    VANSCHADEWIJK, A
    VANGELDERENBOELE, S
    TANKE, HJ
    CYTOMETRY, 1990, 11 (07): : 784 - 792
  • [7] Time-resolved luminescence screening assay for tetracyclines in chicken muscle
    Schneider, MJ
    Chen, GY
    ANALYTICAL LETTERS, 2004, 37 (10) : 2067 - 2078
  • [8] A monoclonal antibody-based time-resolved fluorescence microsphere lateral flow immunoassay for paclobutrazol detection
    Cheng, Yongjian
    Xie, Bo
    Liang, Yifan
    Liu, Xinmei
    Chen, Haojie
    Li, Jiadong
    Lei, Hongtao
    Xiao, Zhili
    CURRENT RESEARCH IN FOOD SCIENCE, 2022, 5 : 1395 - 1402
  • [9] Rapid and sensitive detection of interleukin-6 in serum via time-resolved lateral flow immunoassay
    Huang, Dezhi
    Ying, Haojun
    Jiang, Dongneng
    Liu, Fei
    Tian, Ye
    Du, Chunlan
    Zhang, Liqun
    Pu, Xiaoyun
    ANALYTICAL BIOCHEMISTRY, 2020, 588
  • [10] Preparation and Time-Resolved Luminescence Bioassay Application of Multicolor Luminescent Lanthanide Nanoparticles
    Jiang, Hongfei
    Wang, Guilan
    Zhang, Wenzhu
    Liu, Xiaoyu
    Ye, Zhiqiang
    Jin, Dayong
    Yuan, Jingli
    Liu, Zhiguang
    JOURNAL OF FLUORESCENCE, 2010, 20 (01) : 321 - 328