Sulfoacylated poly(styrene-divinylbenzene) copolymers as resins for cation chromatography - Comparison with sulfonated, dynamically coated and silica gel cation exchangers

被引:8
作者
Klingenberg, A
Seubert, A
机构
[1] Univ Marburg, Dept Chem Analyt Chem, D-35032 Marburg, Germany
[2] Univ Hannover, Inst Inorgan Chem, D-30167 Hannover, Germany
关键词
cation exchangers; stationary phase; LC; sulfoacylated poly(styrene-divinylbenzene) copolymers;
D O I
10.1016/S0021-9673(01)01538-2
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Most important properties of an ion chromatographic resin are influenced by the resin matrix, the type of functional group and the ion-exchange capacity. Highly crosslinked PS-DVB resins of 5 mum. diameter have been functionalized by sulfoacylation, by sulfonation and by dynamic coating over a wide range of exchange capacities. These materials allow a study of the influence of different ion-exchange sites and capacities. The influence of the degree of functionalization on resin performance is completely reverse for sulfoacylated and sulfonated resins. The HETP values for all observed analytes (Cu, Pb, Zn, Ni, Co, Cd, Mn, Ca, Mg) in a tartaric acid elution system decrease for sulfoacylated resins with increasing capacity, for sulfonated resins with decreasing capacity. The performance of sulfoacylated exchangers is better than for dynamically coated ones and far better than for sulfonated resins. The performance of silica gel based cation-exchangers such as BioSil CAT is in most cases better than observed for sulfoacylated resins. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:91 / 97
页数:7
相关论文
共 17 条
[1]   CONTRIBUTION OF LONGITUDINAL DIFFUSION TO BAND BROADENING IN LIQUID-CHROMATOGRAPHY [J].
BERTHOD, A ;
CHARTIER, F ;
ROCCA, JL .
JOURNAL OF CHROMATOGRAPHY, 1989, 469 :53-65
[2]  
Broadbent S. R, 1957, P CAMBRIDGE PHIL SOC, V53, P629, DOI DOI 10.1017/S0305004100032680
[3]  
Fritz J. S., 2000, ION CHROMATOGRAPHY, P61
[4]  
Haddad P.R., 1990, ION CHROMATOGRAPHY P, DOI DOI 10.1016/S0301-4770(08)61141-0
[5]   MODELING OF CATION RETENTION IN ION CHROMATOGRAPHY USING FIXED-SITE AND DYNAMICALLY COATED ION-EXCHANGE COLUMNS [J].
HADDAD, PR ;
FOLEY, RC .
JOURNAL OF CHROMATOGRAPHY, 1990, 500 :301-312
[6]   COMPARISON OF EFFICIENCY OF CATION-EXCHANGE RESINS IN CHROMATOGRAPHIC-SEPARATION OF METAL-IONS WITH AQUEOUS ACETONE HYDROCHLORIC ACID-SOLUTION [J].
KAWAZU, K .
JOURNAL OF CHROMATOGRAPHY, 1977, 137 (02) :381-396
[7]   COMPARISON OF SILICA-BASED AND POLYMER-BASED CATION-EXCHANGERS FOR THE ION-CHROMATOGRAPHIC SEPARATION OF TRANSITION-METALS [J].
KLINGENBERG, A ;
SEUBERT, A .
JOURNAL OF CHROMATOGRAPHY, 1993, 640 (1-2) :167-178
[8]   Sulfoacylated polystyrene-divinylbenzene copolymers as resins for cation chromatography - Influence of capacity on resin selectivity [J].
Klingenberg, A ;
Seubert, A .
JOURNAL OF CHROMATOGRAPHY A, 1998, 804 (1-2) :63-68
[9]  
KLINGENBERG A, 1991, THESIS U HANNOVER
[10]   PRACTICAL ASPECTS OF LC THEORY [J].
KNOX, JH .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1977, 15 (09) :352-364