DC flow analysis and second orifice version pulse tube refrigerator

被引:11
作者
Yang, LW [1 ]
Zhou, Y [1 ]
Liang, JT [1 ]
机构
[1] Chinese Acad Sci, Cryogen Lab, Beijing 100080, Peoples R China
基金
中国国家自然科学基金;
关键词
pulse tube refrigerator; DC flow and its direction; second orifice; experiment;
D O I
10.1016/S0011-2275(99)00029-6
中图分类号
O414.1 [热力学];
学科分类号
摘要
This paper analyzes direct current flow (DC flow) due to double-inlet, and introduces a second orifice version pulse tube refrigerator experiment to diminish DC flow. Analysis based on some assumptions shows that DC flow through the double-inlet valve in the pulse tube refrigerator is not generally zero, and the DC flow direction may change when the pressure wave changes. Thus, different schemes should be developed for different DC flow directions. In experiments, through measuring the change of temperature near the hot end of the pulse tube, DC flow direction different from former in pulse tube is decided. The second orifice is arranged from the second-stage reservoir to high pressure of the compressor, instead of the traditional arrangement of from the reservoir to low pressure. Experiments with the newly arranged second orifice show that the lowest temperature is about 4 K lower than without the second orifice. (C) 1999 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:187 / 192
页数:6
相关论文
共 7 条
[1]   Experimental study on a double-orifice two-stage pulse tube refrigerator [J].
Chen, G ;
Qiu, L ;
Zheng, J ;
Yan, P ;
Gan, Z ;
Bai, X ;
Huang, Z .
CRYOGENICS, 1997, 37 (05) :271-273
[2]  
GAO JL, 1994, CRYOGENICS, V34, P25, DOI 10.1016/0011-2275(94)90048-5
[3]   Dynamic experimental investigation of a multi-bypass pulse tube refrigerator [J].
Ju, YL ;
Wang, C ;
Zhou, Y .
CRYOGENICS, 1997, 37 (07) :357-361
[4]   The experimental investigation of a two-stage pulse tube refrigerator [J].
Wang, C ;
Ju, YL ;
Zhou, Y .
CRYOGENICS, 1996, 36 (08) :605-609
[5]   Effects of DC gas flow on performance of two-stage 4 K pulse tube coolers [J].
Wang, C ;
Thummes, G ;
Heiden, C .
CRYOGENICS, 1998, 38 (06) :689-695
[6]  
YANG LW, 1999, J ENG THERMOPHYSICS, V20, P147
[7]  
ZHU SW, 1990, CRYOGENICS, V30, P514, DOI 10.1016/0011-2275(90)90051-D