For monitoring the granule moisture content during a fluidized bed drying (FBD) process, a calibration model building method is proposed for in situ measurement using the near-infrared (NIR) spectroscopy. It is found that the FBD operating conditions such as the chamber temperature and heating power have a nonnegligible impact on the NIR model prediction of granule moisture. By combining these operating variables with the measured NIR spectra for model calibration, the prediction accuracy for online measurement of the granule moisture content under different process conditions could be evidently improved compared to only using the measured NIR spectra for model calibration. To determine the optimal number of factors for establishing a partial-least-squares (PLS) regression model for predicting the granule moisture content, it is proposed to combine the leave-one-out cross validation (LOOCV) approach with the median absolute percentage error (MdAPE) index to deal with measurement outliers often involved with practical applications, based on a comparative study with the well-known K-fold cross validation (KCV) and Monte Carlo cross validation (MCCV) methods. Experimental results on monitoring the silica gel granule moisture under different FBD operating conditions demonstrate the effectiveness of the proposed spectral calibration method.
引用
收藏
页码:6476 / 6485
页数:10
相关论文
共 27 条
[11]   In-Line Multipoint Near-Infrared Spectroscopy for Moisture Content Quantification during Freeze-Drying [J].
Kauppinen, Ari ;
Toiviainen, Maunu ;
Korhonen, Ossi ;
Aaltonen, Jaakko ;
Jarvinen, Kristiina ;
Paaso, Janne ;
Juuti, Mikko ;
Ketolainen, Jarkko .
ANALYTICAL CHEMISTRY, 2013, 85 (04) :2377-2384
[12]   Application of in-line near infrared spectroscopy and multivariate batch modeling for process monitoring in fluid bed granulation [J].
Kona, Ravikanth ;
Qu, Haibin ;
Mattes, Robert ;
Jancsik, Bela ;
Fahmy, Raafat M. ;
Hoag, Stephen W. .
INTERNATIONAL JOURNAL OF PHARMACEUTICS, 2013, 452 (1-2) :63-72
[13]  
Kunii D., 2013, FLUIDIZATION ENG, Vsecond
[14]   libPLS: An integrated library for partial least squares regression and linear discriminant analysis [J].
Li, Hong-Dong ;
Xu, Qing-Song ;
Liang, Yi-Zeng .
CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 2018, 176 :34-43
[15]   Measurement uncertainty from physical sample preparation: estimation including systematic error [J].
Lyn, JA ;
Ramsey, MH ;
Fussell, RJ ;
Wood, R .
ANALYST, 2003, 128 (11) :1391-1398
[16]   The feasibility of using acoustic emissions for monitoring of fluidized bed granulation [J].
Matero, Sanni ;
Poutiainen, Sami ;
Leskinen, Jari ;
Jarvinen, Kristiina ;
Ketolainen, Jarkko ;
Reinikainen, Satu-Pia ;
Hakulinen, Mikko ;
Lappalainen, Reijo ;
Poso, Antti .
CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 2009, 97 (01) :75-81
[17]   Effects of process parameters on solid self-microemulsifying particles in a laboratory scale fluid bed [J].
Mukherjee, Tusharmouli ;
Plakogiannis, Fotios M. .
PHARMACEUTICAL DEVELOPMENT AND TECHNOLOGY, 2012, 17 (04) :511-520
[18]   Influence of controlled ice nucleation on the freeze-drying of pharmaceutical products: the secondary drying step [J].
Oddone, Irene ;
Barresi, Antonello A. ;
Pisano, Roberto .
INTERNATIONAL JOURNAL OF PHARMACEUTICS, 2017, 524 (1-2) :134-140
[19]   Development, validation and transfer of a Near Infrared method to determine in-line the end point of a fluidised drying process for commercial production batches of an approved oral solid dose pharmaceutical product [J].
Peinado, Antonio ;
Hammond, Jonathan ;
Scott, Andrew .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2011, 54 (01) :13-20
[20]   Fourier Transform Near-Infrared Spectroscopy as a Reliable Method for Quick Real Time Analysis of Complex Samples in Industry [J].
Pereira, Carlos M. F. S. ;
Brites Alves, Ana Maria F. ;
Vieira, Ana Cristina F. G. A. .
INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2013, 52 (32) :10873-10879