Locking versus non-locking plates in fixation of extra-articular distal humerus fracture: a randomized controlled study

被引:4
|
作者
Galal, Sherif [1 ,2 ]
Mattar, Yasser [1 ]
Solyman, Alaa Mohy Eldin [1 ]
Ezzat, Mostafa [1 ]
机构
[1] Cairo Univ, Fac Med, Dept Orthopaed Surg, Cairo 11559, Egypt
[2] Hosp Special Surg, Dept Orthopaed Surg, 535 E 70th St, New York, NY 10021 USA
关键词
Distal humerus; Fracture; Fixation; Locking plates; Randomized controlled; INTERNAL-FIXATION; INTERCONDYLAR FRACTURES; OPEN REDUCTION;
D O I
10.1007/s00264-020-04770-z
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Introduction Studies have shown that the use of nonlocking (reconstruction) plates in fixing distal humerus fractures may not yield stable fixation which therefore requires long immobilization and suboptimal functional results. There are reports showing that locking plates are biomechanically superior to nonlocking plates. The aim of this study was to compare elbow functional outcomes between locking and nonlocking plates in fixation of distal humerus fractures. Methods A single-centre, randomized control study was conducted at an academic level 1 trauma centre. A total of 60 patients with type 13-A fracture (AO/OTA classification) were randomized into two equal groups, locking plates group, and nonlocking plates group. The primary outcome measure was the Mayo elbow performance score (MEPS) at one year. Secondary outcomes measures were elbow flexion/extension arc, union, operative time, and complications (e.g., infection, heterotrophic ossification). Results The Mayo Elbow Performance Score (MEPS) at one year was 88 +/- 10.1 in locking plates group and 75.8 +/- 12.8 in nonlocking plates group. The difference was found to be statically significant (Pvalue = 0.01). Elbow flexion/extension arc of motion at one year was 116 degrees +/- 15 degrees in locking plates group and 113 degrees +/- 28 degrees in nonlocking plates. The difference was not found to be statistically significant (Pvalue = 0.17). Conclusion Both implants yield similar results, with locking plates showing slightly better clinical scores.
引用
收藏
页码:2761 / 2767
页数:7
相关论文
共 50 条
  • [21] Are conventional reconstruction plates equivalent to precontoured locking plates for distal humerus fracture fixation? A biomechanics cadaver study
    Koonce, Ryan C.
    Baldini, Todd H.
    Morgan, Steven J.
    CLINICAL BIOMECHANICS, 2012, 27 (07) : 697 - 701
  • [22] A comparison of complication rates between locking and non-locking plates in distal fibular fractures
    Moriarity, A.
    Ellanti, P.
    Mohan, K.
    Fhoghlu, C. Ni
    Fenelon, C.
    McKenna, J.
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2018, 104 (04) : 503 - 506
  • [23] A comparison of bone union and complication rates between locking and non-locking plates in distal fibular fracture: Retrospective study of 106 cases
    El Fatayri, Bachar
    Bulaid, Yassine
    Djebara, Az-Eddine
    Havet, Eric
    Mertl, Patrice
    Dehl, Massinissa
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2019, 50 (12): : 2324 - 2331
  • [24] Locking versus non-locking plating system in the treatment of mandibular fractures: A randomized comparative study
    Sarkar, Dibya Falgoon
    Mishra, Niranjan
    Samal, Dipti
    Pati, Debashish
    Kar, Indu Bhusan
    Mohapatra, Debjyoti
    Mishra, Abhipsa
    JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 2021, 49 (03) : 184 - 190
  • [25] What happens to the posterior comminution in extra-articular fractures of the distal radius treated with volar locking plates?
    Guillou, J.
    Darees, M.
    Pouges, C.
    Christiaens, N.
    Guerre, E.
    Chantelot, C.
    HAND SURGERY & REHABILITATION, 2019, 38 (02) : 91 - 96
  • [26] Treatment of extra-articular and simple articular distal radial fractures with intramedullary nail versus volar locking plate
    Safi, A.
    Hart, R.
    Teknedzjan, B.
    Kozak, T.
    JOURNAL OF HAND SURGERY-EUROPEAN VOLUME, 2013, 38 (07) : 774 - 779
  • [27] Outcome of precontoured locking compression plate in patients with distal humerus intra-articular fracture
    Jatoi, Asif Ali
    Lakho, Muhammad Tahir
    Khanzada, Muhammad Azfar
    Shaikh, Aijaz Ali
    Memon, Zulfiqar Ali
    Bhatti, Anis Uddin
    RAWAL MEDICAL JOURNAL, 2020, 45 (01): : 111 - 114
  • [28] Biomechanical Analysis of Volar and Dorsal Double Locking Plates for Fixation in Comminuted Extra-articular Distal Radius Fractures: A 3D Finite Element Study
    Lin, Yu-Hao
    Lin, Chun-Li
    Kuo, Hsien-Nan
    Sun, Ming-Tsung
    Chen, Alvin Chao-Yu
    JOURNAL OF MEDICAL AND BIOLOGICAL ENGINEERING, 2012, 32 (05) : 349 - 355
  • [29] Comparative Evaluation of 3d Locking Versus Non-Locking Titanium Miniplates in the Treatment of Mandibular Fracture
    Khan, Mohsin
    Vishal
    Kumar, Ashish
    Khaitan, Tanya
    Sinha, Dharmendra Kumar
    Kumar, Chandan
    INDIAN JOURNAL OF OTOLARYNGOLOGY AND HEAD & NECK SURGERY, 2020, 72 (03) : 363 - 369
  • [30] Monofilament cerclage wiring fixation with locking plates for distal femoral fracture: Is it appropriate?
    Lee, Sung Hyun
    Choi, Young Chae
    Kweon, Suc Hyun
    INDIAN JOURNAL OF ORTHOPAEDICS, 2019, 53 (06) : 689 - 694