Effects of flow rate and rotational speed on pressure fluctuations in a double-suction centrifugal pump

被引:60
作者
Wang, Zhiyuan [1 ]
Qian, Zhongdong [1 ]
Lu, Jie [1 ]
Wu, Pengfei [1 ]
机构
[1] Wuhan Univ, State Key Lab Water Resources & Hydropower Engn S, Wuhan 430072, Hubei, Peoples R China
基金
中国国家自然科学基金;
关键词
Double-suction centrifugal pump; Flow rate; Rotational speed; Pressure fluctuations; UNSTEADY-FLOW; PART I; PERFORMANCE; IMPELLER; TURBINE; DESIGN; ROUGHNESS; TONGUE;
D O I
10.1016/j.energy.2018.12.112
中图分类号
O414.1 [热力学];
学科分类号
摘要
Pressure fluctuations in double-suction centrifugal pumps are greatly affected by the flow rate and rotational speed. An experimental investigation was carried out to determine effects of the flow rate and rotational speed for optimizing the hydraulic design and realizing stable operation. Pressure fluctuation signals were obtained at five measurement points along the suction chamber and four measurement points along the discharge chamber by means of pressure transmitters. The flow rates ranged from 0% to 150% of the design flow rate, and the rotational speed was reduced to 850 rpm from the rated speed of 1450 rpm. Results show that the third harmonic of rotational frequency is detected as the dominant frequency in the upper part of the suction chamber at low flow rates. At zero flow rate, the pressure fluctuations increase by 200% above that at the design flow rate. The pressure fluctuations decrease by 50% as the speed is reduced from the rated speed of 1450 rpm to 1250 rpm. At 850 rpm, the pressure fluctuations at partial flow rates are larger than those at higher rotational speeds, and the maximum efficiency is 5% less than that at the rated speed of 1450 rpm. (C) 2018 Elsevier Ltd. All rights reserved.
引用
收藏
页码:212 / 227
页数:16
相关论文
共 38 条
[1]   A review on energy saving strategies in industrial sector [J].
Abdelaziz, E. A. ;
Saidur, R. ;
Mekhilef, S. .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2011, 15 (01) :150-168
[2]   Energy efficiency optimizing speed control method for reservoir pumping applications [J].
Ahonen, Tero ;
Tamminen, Jussi ;
Viholainen, Juha ;
Koponen, Joonas .
ENERGY EFFICIENCY, 2015, 8 (01) :117-128
[3]  
Chang W, 2012, IEEE SYS MAN CYBERN, P2395, DOI 10.1109/ICSMC.2012.6378101
[4]  
Chini SF, 2005, Proceedings of the ASME International Design Engineering Technical Conferences and Computers and Information in Engineering Conference, Vol 1, Pts A-C, P13
[5]   Operational energy-efficiency improvement of municipal water pumping in California [J].
DeBenedictis, A. ;
Haley, B. ;
Woo, C. K. ;
Cutter, E. .
ENERGY, 2013, 53 :237-243
[6]   Effect of modification to tongue and impeller geometry on unsteady flow, pressure fluctuations, and noise in a centrifugal pump [J].
Dong, R ;
Chu, S ;
Katz, J .
JOURNAL OF TURBOMACHINERY-TRANSACTIONS OF THE ASME, 1997, 119 (03) :506-515
[7]   The use of variable speed drives for cost-effective energy savings in South African mine cooling systems [J].
Du Plessis, Gideon Edgar ;
Liebenberg, Leon ;
Mathews, Edward Henry .
APPLIED ENERGY, 2013, 111 :16-27
[8]   Case study: The effects of a variable flow energy saving strategy on a deep-mine cooling system [J].
du Plessis, Gideon Edgar ;
Liebenberg, Leon ;
Mathews, Edward Henry .
APPLIED ENERGY, 2013, 102 :700-709
[9]   Experimental comparison and analysis on silica gel and polymer coated fin-tube heat exchangers [J].
Ge, T. S. ;
Dai, Y. J. ;
Wang, R. Z. ;
Peng, Z. Z. .
ENERGY, 2010, 35 (07) :2893-2900
[10]   Steady and unsteady radial forces for a centrifugal pump with impeller to tongue gap variation [J].
Gonzalez, Jose ;
Parrondo, Jorge ;
Santolaria, Carlos ;
Blanco, Eduardo .
JOURNAL OF FLUIDS ENGINEERING-TRANSACTIONS OF THE ASME, 2006, 128 (03) :454-462