A novel amperometric glucose biosensor based on poly(glycidyl methacrylate-co-(3-thienylmethylmethacrylate))

被引:9
|
作者
Karagollu, Osman [1 ]
Gorur, Mesut [2 ]
Turkan, Ali [3 ]
Sengez, Busra [2 ,3 ]
Gode, Fethiye [1 ]
Yilmaz, Faruk [3 ]
机构
[1] Suleyman Demirel Univ, Fac Arts & Sci, Dept Chem, TR-32260 Isparta, Turkey
[2] Istanbul Medeniyet Univ, Fac Sci, Dept Chem, TR-34720 Istanbul, Turkey
[3] Gebze Inst Technol, Dept Chem, TR-41400 Gebze, Kocaeli, Turkey
关键词
Amperometric biosensor; Glucose oxidase; Enzyme-modified electrode; Covalent immobilization; TYPE-2; DIABETES-MELLITUS; HORSERADISH-PEROXIDASE; HYDROGEN-PEROXIDE; COVALENT IMMOBILIZATION; ENZYME IMMOBILIZATION; GOLD NANOPARTICLES; CONDUCTING POLYMER; ELECTRODE; NANOCOMPOSITES; NANOFIBERS;
D O I
10.1016/j.cap.2012.11.013
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Two novel glucose oxidase (GOx) enzyme electrodes based on the copolymer of glycidyl methacrylate with 3-thienylmethyl methacrylate (poly(GMA-co-MTM)) with and without polypyrrole (PPyr) coating were prepared and employed in the amperometric determination of glucose levels. The effect of PPyr coating on the electrode properties was investigated in detail. Cyclic voltammetry studies showed that electrical conductivity of electrode B with PPyr coating (poly(GMA-co-MTM)/GOx/PPyr) was substantially higher than that of electrode A (poly(GMA-co-MTM)/GOx). On the other hand, electrode A showed better results in terms of sensitivity (10 nA/mM), limit of detection (50.2 mu M), and response time (5 s). Electrodes A and B gave linear responses to the glucose concentrations in the range of 2-20 and 2-14 mM, respectively. The ranges of linearity for both enzyme electrodes are sufficient for the determination of physiological glucose concentrations in human blood. Moreover, PPyr coating of electrode B did not result in further stabilization of the enzyme electrode. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:725 / 730
页数:6
相关论文
共 50 条
  • [1] A Novel Amperometric Hydrogen Peroxide Biosensor Based on Catalase Immobilization on Poly(glycidyl methacrylate-co-vinylferrocene)
    Senel, Mehmet
    Cevik, Emre
    Abasiyanik, M. Fatih
    ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY, 2011, 3 (01): : 14 - 25
  • [2] Construction of a Novel Glucose Biosensor Based on Covalent Immobilization of Glucose Oxidase on Poly(glycidyl methacrylate-co-vinylferrocene)
    Senel, Mehmet
    Abasiyanik, M. Fatih
    ELECTROANALYSIS, 2010, 22 (15) : 1765 - 1771
  • [3] Newly synthesized poly(glycidyl methacrylate-co-3-thienylmethylmethacrylate)-based electrode designs for phenol biosensors
    Ozoner, Seyda Korkut
    Erhan, Elif
    Yilmaz, Faruk
    Celik, Asuman
    Keskinler, Bulent
    TALANTA, 2010, 81 (1-2) : 82 - 87
  • [4] Poly(glycidyl methacrylate-co-3-thienylmethylmethacrylate) as an immobilization matrix for microbial glycerol biosensing based on Gluconobacter oxydans
    Ergon-Can, Tulay
    Erhan, Elif
    Algur, Omer Faruk
    MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2015, 56 : 432 - 437
  • [5] Amperometric glucose biosensor based on biocompatible poly(dimethylaminoethyl) methacrylate microparticles
    Hervas Perez, J. P.
    Lopez-Cabarcos, E.
    Lopez-Ruiz, B.
    TALANTA, 2010, 81 (4-5) : 1197 - 1202
  • [6] A novel amperometric biosensor based on ZnO:Co nanoclusters for biosensing glucose
    Zhao, Z. W.
    Chen, X. J.
    Tay, B. K.
    Chen, J. S.
    Han, Z. J.
    Khor, Khiam Aik
    BIOSENSORS & BIOELECTRONICS, 2007, 23 (01): : 135 - 139
  • [7] Interference elimination of an amperometric glucose biosensor using poly(hydroxyethyl methacrylate) membrane
    Abdul-Aziz, Azila
    Wong, Fui-Ling
    ENGINEERING IN LIFE SCIENCES, 2011, 11 (01): : 20 - 25
  • [8] An amperometric urea biosensor based on covalent immobilization of urease on copolymer of glycidyl methacrylate and vinylferrocene
    Cevik, Emre
    Senel, Mehmet
    Abasiyanik, Mustafa Fatih
    JOURNAL OF SOLID STATE ELECTROCHEMISTRY, 2012, 16 (01) : 367 - 373
  • [9] An amperometric urea biosensor based on covalent immobilization of urease on copolymer of glycidyl methacrylate and vinylferrocene
    Emre Çevik
    Mehmet Şenel
    Mustafa Fatih Abasıyanık
    Journal of Solid State Electrochemistry, 2012, 16 : 367 - 373
  • [10] A novel stable amperometric glucose biosensor based on the adsorption of glucose oxidase on poly(methyl methacrylate)-bovine serum albumin core-shell nanoparticles
    He, Chuanxin
    Liu, Jianhong
    Zhang, Qianling
    Wu, Chi
    SENSORS AND ACTUATORS B-CHEMICAL, 2012, 166 : 802 - 808