Evaluation of different sized blood sampling tubes for thromboelastometry, platelet function, and platelet count

被引:13
|
作者
Andreasen, Jo Bonding [2 ]
Pistor-Riebold, Thea Unger [3 ]
Knudsen, Ingrid Hell [3 ]
Ravn, Hanne Berg [2 ]
Hvas, Anne-Mette [1 ]
机构
[1] Aarhus Univ Hosp, Dept Clin Biochem, Ctr Haemophilia & Thrombosis, DK-8200 Aarhus N, Denmark
[2] Aarhus Univ Hosp, Dept Anaesthesiol & Intens Care, DK-8200 Aarhus N, Denmark
[3] Aarhus Univ, Fac Hlth Sci, Aarhus, Denmark
关键词
blood sampling; coagulation; paediatric; platelet aggregation; preanalytical variables; QUALITY STANDARDS; AGGREGOMETRY; TRANSFUSIONS; COLLECTION; TRANSPORT; EDTA; ROTEM(R); SYSTEM;
D O I
10.1515/cclm-2013-0836
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background: To minimise the volume of blood used for diagnostic procedures, especially in children, we investigated whether the size of sample tubes affected whole blood coagulation analyses. Methods: We included 20 healthy individuals for rotational thromboelastometry (RoTEM (R)) analyses and compared three blood sampling tubes of different size: 1.8, 2.7, and 3.6 mL. All tubes were made of plastic and contained 3.2% sodium-citrate as anticoagulant. Platelet aggregation was investigated in 12 healthy individuals employing the Multiplate (R) Analyser comparing tubes of 3.6 mL and 1.8 mL. Platelet count was determined for each of the sampling tubes after 10, 60, and 120 min. Results: No significant differences were found in any of the RoTEM (R) measurements between the three sizes of tubes (p=0.07-0.53). Platelet aggregation was significantly lower when using smaller tubes (p=0.0004). The platelet count remained stable using a 3.6 mL tube during the entire observation period of 120 min (p=0.74), but decreased significantly after 60 min when using tubes smaller than 3.6 mL (p<0.0001). Conclusions: RoTEM (R) analyses were not affected by the size of blood sampling tubes. Therefore, 1.8 mL tubes should be preferred for RoTEM (R) analyses in order to minimise the volume of blood drawn. With regard to platelet aggregation analysed by impedance aggregometry tubes of different size cannot be used interchangeably. If platelet count is determined later than 10 min after blood sampling using tubes containing citrate as anticoagulant, a 3.6 mL tube should be preferred to avoid false low values.
引用
收藏
页码:701 / 706
页数:6
相关论文
共 50 条
  • [41] EVALUATION OF PLATELET FUNCTION BY MEASURING PLATELET ADHESION AND AGGREGATION ON POLYSTYRENE SURFACE IN PATIENTS WITH ESSENTIAL THROMBOCYTHEMIA
    Trdina, Katarina
    Kralj, Jana
    Cernelc, Peter
    ZDRAVNISKI VESTNIK-SLOVENIAN MEDICAL JOURNAL, 2008, 77 : I63 - I68
  • [42] Evaluation of platelet function with the PFA-100 system in patients with congenital defects of platelet secretion
    Cattaneo, M
    Lecchi, A
    Agati, B
    Lombardi, R
    Zighetti, ML
    THROMBOSIS RESEARCH, 1999, 96 (03) : 213 - 217
  • [43] Comparison of three common whole blood platelet function tests for in vitro P2Y12 induced platelet inhibition
    Dias, Joao D.
    Pottgiesser, Torben
    Hartmann, Jan
    Duerschmied, Daniel
    Bode, Christoph
    Achneck, Hardean E.
    JOURNAL OF THROMBOSIS AND THROMBOLYSIS, 2020, 50 (01) : 135 - 143
  • [44] Evaluation of platelet function in aspirin treated patients with CAD
    Williams, MS
    Kickler, TS
    Vaidya, D
    Ng'alla, LS
    Bush, DE
    JOURNAL OF THROMBOSIS AND THROMBOLYSIS, 2006, 21 (03) : 241 - 247
  • [45] Rapid evaluation of platelet function using the Multiplate® Analyzer
    Wurtz, Morten
    Hvas, Anne-Mette
    Christensen, Kristian Hylleberg
    Rubak, Peter
    Kristensen, Steen Dalby
    Grove, Erik Lerkevang
    PLATELETS, 2014, 25 (08) : 628 - 633
  • [46] Evaluation of platelet function in aspirin treated patients with CAD
    Marlene S. Williams
    Thomas S. Kickler
    Dhananjay Vaidya
    Ladina S. Ng’alla
    David E. Bush
    Journal of Thrombosis and Thrombolysis, 2006, 21 : 241 - 247
  • [47] A Detailed Examination of Platelet Function Inhibition by Nitric Oxide in Platelet-Rich Plasma and Whole Blood
    Zimmermann, Robert
    Krueger, Julia
    Filipovic, Milos R.
    Ivanovic-Burmazovic, Ivana
    Calatzis, Andreas
    Weiss, Dominik R.
    Eckstein, Reinhold
    CLINICAL LABORATORY, 2013, 59 (5-6) : 629 - 638
  • [48] High Content Evaluation of Shear Dependent Platelet Function in a Microfluidic Flow Assay
    Hansen, Ryan R.
    Wufsus, Adam R.
    Barton, Steven T.
    Onasoga, Abimbola A.
    Johnson-Paben, Rebecca M.
    Neeves, Keith B.
    ANNALS OF BIOMEDICAL ENGINEERING, 2013, 41 (02) : 250 - 262
  • [49] Effect of Aerobic Interval Training and Caffeine on Blood Platelet Function
    Whittaker, Joshua P.
    Linden, Matthew D.
    Coffey, Vernon G.
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2013, 45 (02) : 342 - 350
  • [50] The Hydraulic Permeability of Blood Clots as a Function of Fibrin and Platelet Density
    Wufsus, A. R.
    Macera, N. E.
    Neeves, K. B.
    BIOPHYSICAL JOURNAL, 2013, 104 (08) : 1812 - 1823