Evaluation of different sized blood sampling tubes for thromboelastometry, platelet function, and platelet count

被引:13
|
作者
Andreasen, Jo Bonding [2 ]
Pistor-Riebold, Thea Unger [3 ]
Knudsen, Ingrid Hell [3 ]
Ravn, Hanne Berg [2 ]
Hvas, Anne-Mette [1 ]
机构
[1] Aarhus Univ Hosp, Dept Clin Biochem, Ctr Haemophilia & Thrombosis, DK-8200 Aarhus N, Denmark
[2] Aarhus Univ Hosp, Dept Anaesthesiol & Intens Care, DK-8200 Aarhus N, Denmark
[3] Aarhus Univ, Fac Hlth Sci, Aarhus, Denmark
关键词
blood sampling; coagulation; paediatric; platelet aggregation; preanalytical variables; QUALITY STANDARDS; AGGREGOMETRY; TRANSFUSIONS; COLLECTION; TRANSPORT; EDTA; ROTEM(R); SYSTEM;
D O I
10.1515/cclm-2013-0836
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background: To minimise the volume of blood used for diagnostic procedures, especially in children, we investigated whether the size of sample tubes affected whole blood coagulation analyses. Methods: We included 20 healthy individuals for rotational thromboelastometry (RoTEM (R)) analyses and compared three blood sampling tubes of different size: 1.8, 2.7, and 3.6 mL. All tubes were made of plastic and contained 3.2% sodium-citrate as anticoagulant. Platelet aggregation was investigated in 12 healthy individuals employing the Multiplate (R) Analyser comparing tubes of 3.6 mL and 1.8 mL. Platelet count was determined for each of the sampling tubes after 10, 60, and 120 min. Results: No significant differences were found in any of the RoTEM (R) measurements between the three sizes of tubes (p=0.07-0.53). Platelet aggregation was significantly lower when using smaller tubes (p=0.0004). The platelet count remained stable using a 3.6 mL tube during the entire observation period of 120 min (p=0.74), but decreased significantly after 60 min when using tubes smaller than 3.6 mL (p<0.0001). Conclusions: RoTEM (R) analyses were not affected by the size of blood sampling tubes. Therefore, 1.8 mL tubes should be preferred for RoTEM (R) analyses in order to minimise the volume of blood drawn. With regard to platelet aggregation analysed by impedance aggregometry tubes of different size cannot be used interchangeably. If platelet count is determined later than 10 min after blood sampling using tubes containing citrate as anticoagulant, a 3.6 mL tube should be preferred to avoid false low values.
引用
收藏
页码:701 / 706
页数:6
相关论文
共 50 条
  • [21] Quantification of Both Platelet Count and Fibrinogen Concentration Using Maximal Clot Firmness of Thromboelastometry During Liver Transplantation
    Jeong, S. -M.
    Song, J. -G.
    Seo, H.
    Choi, J. -H.
    Jang, D. -M.
    Hwang, G. -S.
    TRANSPLANTATION PROCEEDINGS, 2015, 47 (06) : 1890 - 1895
  • [22] Whole blood platelet aggregation measurement by Multiplate™: potential diagnostic inaccuracy of correcting the results for the sample platelet count
    Scavone, Mariangela
    Podda, Gian Marco
    Tripodi, Armando
    Cattaneo, Marco
    PLATELETS, 2023, 34 (01)
  • [23] Assessment of platelet function in healthy sedated cats using three whole blood platelet function tests
    Ho, Kimberly K.
    Abrams-Ogg, Anthony C. G.
    Wood, R. Darren
    O'Sullivan, M. Lynne
    Kirby, Gordon M.
    Blois, Shauna L.
    JOURNAL OF VETERINARY DIAGNOSTIC INVESTIGATION, 2015, 27 (03) : 352 - 360
  • [24] Platelet function testing: Update on determinant variables and permissive windows using a platelet-count-based device
    Villar, Patricia
    Carreno, Sofia
    Moro, Sara
    Galindo, Ines Diez
    Bernardo, Angel
    Gutierrez, Laura
    TRANSFUSION AND APHERESIS SCIENCE, 2024, 63 (03)
  • [25] Optimized tool for evaluation of platelet function measured by impedance aggregometry
    Schultz-Lebahn, Anna
    Skipper, Mette Tiedemann
    Hvas, Anne-Mette
    Larsen, Ole Halfdan
    PLATELETS, 2021, 32 (06) : 842 - 845
  • [26] A mathematical model for in vitro coagulation of blood: role of platelet count and inhibition
    Susree, M.
    Anand, M.
    SADHANA-ACADEMY PROCEEDINGS IN ENGINEERING SCIENCES, 2017, 42 (03): : 291 - 305
  • [27] A mathematical model for in vitro coagulation of blood: role of platelet count and inhibition
    M Susree
    M Anand
    Sādhanā, 2017, 42 : 291 - 305
  • [28] Arachidonic acid causes lysis of blood cells and ADP-dependent platelet activation responses in platelet function tests
    Ramstrom, Sofia
    PLATELETS, 2019, 30 (08) : 1001 - 1007
  • [29] Complement function and activation in human serum and plasma collected in different blood collection tubes
    Andersson, Linnea I.
    Sjostrom, Dick J.
    Brandwijk, Ricardo J. M. G. E.
    Toonen, Erik J. M.
    Mollnes, Tom Eirik
    Nilsson, Per H.
    JOURNAL OF IMMUNOLOGICAL METHODS, 2025, 538
  • [30] Platelet Function in Stored Heparinised Autologous Blood Is Not Superior to in Patient Platelet Function during Routine Cardiopulmonary Bypass
    Huet, Rolf C. G. Gallandat
    de Vries, Adrianus J.
    Cernak, Vladimir
    Lisman, Ton
    PLOS ONE, 2012, 7 (03):