Evaluation of different sized blood sampling tubes for thromboelastometry, platelet function, and platelet count

被引:12
作者
Andreasen, Jo Bonding [2 ]
Pistor-Riebold, Thea Unger [3 ]
Knudsen, Ingrid Hell [3 ]
Ravn, Hanne Berg [2 ]
Hvas, Anne-Mette [1 ]
机构
[1] Aarhus Univ Hosp, Dept Clin Biochem, Ctr Haemophilia & Thrombosis, DK-8200 Aarhus N, Denmark
[2] Aarhus Univ Hosp, Dept Anaesthesiol & Intens Care, DK-8200 Aarhus N, Denmark
[3] Aarhus Univ, Fac Hlth Sci, Aarhus, Denmark
关键词
blood sampling; coagulation; paediatric; platelet aggregation; preanalytical variables; QUALITY STANDARDS; AGGREGOMETRY; TRANSFUSIONS; COLLECTION; TRANSPORT; EDTA; ROTEM(R); SYSTEM;
D O I
10.1515/cclm-2013-0836
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background: To minimise the volume of blood used for diagnostic procedures, especially in children, we investigated whether the size of sample tubes affected whole blood coagulation analyses. Methods: We included 20 healthy individuals for rotational thromboelastometry (RoTEM (R)) analyses and compared three blood sampling tubes of different size: 1.8, 2.7, and 3.6 mL. All tubes were made of plastic and contained 3.2% sodium-citrate as anticoagulant. Platelet aggregation was investigated in 12 healthy individuals employing the Multiplate (R) Analyser comparing tubes of 3.6 mL and 1.8 mL. Platelet count was determined for each of the sampling tubes after 10, 60, and 120 min. Results: No significant differences were found in any of the RoTEM (R) measurements between the three sizes of tubes (p=0.07-0.53). Platelet aggregation was significantly lower when using smaller tubes (p=0.0004). The platelet count remained stable using a 3.6 mL tube during the entire observation period of 120 min (p=0.74), but decreased significantly after 60 min when using tubes smaller than 3.6 mL (p<0.0001). Conclusions: RoTEM (R) analyses were not affected by the size of blood sampling tubes. Therefore, 1.8 mL tubes should be preferred for RoTEM (R) analyses in order to minimise the volume of blood drawn. With regard to platelet aggregation analysed by impedance aggregometry tubes of different size cannot be used interchangeably. If platelet count is determined later than 10 min after blood sampling using tubes containing citrate as anticoagulant, a 3.6 mL tube should be preferred to avoid false low values.
引用
收藏
页码:701 / 706
页数:6
相关论文
共 27 条
[1]   Thromboelastography-Based Transfusion Algorithm Reduces Blood Product Use after Elective CABG: A Prospective Randomized Study [J].
Ak, Koray ;
Isbir, Cemil S. ;
Tetik, Sermin ;
Atalan, Nazan ;
Tekeli, Atike ;
Aljodi, Maher ;
Civelek, Ali ;
Arsan, Sinan .
JOURNAL OF CARDIAC SURGERY, 2009, 24 (04) :404-410
[2]   Can RoTEM® analysis be applied for haemostatic monitoring in paediatric congenital heart surgery? [J].
Andreasen, Jo Bonding ;
Hvas, Anne-Mette ;
Christiansen, Kirsten ;
Ravn, Hanne Berg .
CARDIOLOGY IN THE YOUNG, 2011, 21 (06) :684-691
[3]   Determinants of red blood cell transfusions in a pediatric critical care unit: A prospective, descriptive epidemiological study [J].
Armano, R ;
Gauvin, F ;
Ducruet, T ;
Lacroix, J .
CRITICAL CARE MEDICINE, 2005, 33 (11) :2637-2644
[4]   The role of ethylenedimine tetraacetic acid (EDTA) as in vitro anticoagulant for diagnostic purposes [J].
Banfi, Giuseppe ;
Salvagno, Gian Luca ;
Lippi, Giuseppe .
CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2007, 45 (05) :565-576
[5]   Screening for EDTA-dependent deviations in platelet counts and abnormalities in platelet distribution histograms in pseudothrombocytopenia [J].
Bartels, PCM ;
Schoorl, M ;
Lombarts, AJPF .
SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 1997, 57 (07) :629-636
[6]   Anemia, blood loss, and blood transfusions in North American children in the intensive care unit [J].
Bateman, Scot T. ;
Lacroix, Jacques ;
Boven, Katia ;
Forbes, Peter ;
Barton, Roger ;
Thomas, Neal J. ;
Jacobs, Brian ;
Markovitz, Barry ;
Goldstein, Brahm ;
Hanson, James H. ;
Li, H. Agnes ;
Randolph, Adrienne G. .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2008, 178 (01) :26-33
[7]  
Calatzis A, 2009, Hamostaseologie, V29, P279
[8]   The predictive value of modified computerized thromboelastography and platelet function analysis for postoperative blood loss in routine cardiac surgery [J].
Cammerer, U ;
Dietrich, W ;
Rampf, T ;
Braun, SL ;
Richter, JA .
ANESTHESIA AND ANALGESIA, 2003, 96 (01) :51-57
[9]   Results of a worldwide survey on the assessment of platelet function by light transmission aggregometry: a report from the platelet physiology subcommittee of the SSC of the ISTH [J].
Cattaneo, M. ;
Hayward, C. P. M. ;
Moffat, K. A. ;
Pugliano, M. T. ;
Liu, Y. ;
Michelson, A. D. .
JOURNAL OF THROMBOSIS AND HAEMOSTASIS, 2009, 7 (06) :1029-1029
[10]   Contemporary platelet function testing [J].
Favaloro, Emmanuel J. ;
Lippi, Giuseppe ;
Franchini, Massimo .
CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2010, 48 (05) :579-598