Seismic behavior of novel GFRP bar reinforced concrete beam-column joints internally reinforced with an FRP tube

被引:18
作者
Lin, Guan [1 ]
Zeng, Jun-Jie [2 ]
Liang, Sheng-Da [2 ]
Liao, JinJing [2 ]
Zhuge, Yan [3 ]
机构
[1] Southern Univ Sci & Technol, Dept Ocean Sci & Engn, Shenzhen 518055, Guangdong, Peoples R China
[2] Guangdong Univ Technol, Sch Civil & Transportat Engn, Guangzhou 510006, Peoples R China
[3] Univ South Australia, UniSA STEM, Adelaide, SA 5095, Australia
关键词
Fiber-reinforced polymer (FRP) reinforcement; Beam-column joints; FRP tube; Confinement; Seismic performance; Energy dissipation;
D O I
10.1016/j.engstruct.2022.115100
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Due to many advantages, fiber-reinforced polymer (FRP) bars have been considered as a promising alternative to steel bars in reinforced concrete (RC) structures. The use of FRP bars in beam-column joints has been reported in the literature. However, it has been found that the energy dissipation capacity of an FRP-RC beam-column joint is dramatically lower than that of the corresponding steel-RC joint. The present study attempts to develop a novel form of FRP-RC beam-column joints with superior energy dissipation capacity. The proposed joints incorporate an internal FRP tube in the joint zone, which provides confinement to the inner concrete and shear resistance of the joint. Compared with existing reinforcement techniques using stiffeners or internal diaphragms, the proposed use of an internal FRP tube is much easier to be implemented. To demonstrate the advantages of the proposed FRP-RC beam-column joints, an experimental program consisting of 6 FRP-RC beam-column joint specimens was carried out. The effects of fiber type, thickness, and fiber orientation of the FRP tube in the joint zone were investigated. The test results in terms of failure modes, hysteretic behaviors, and energy dissipation capacities of the test specimens were discussed in detail. The test results demonstrated the efficiency of the FRP tube, espe-cially the one with a fiber angle of +/- 45 degrees, in enhancing the energy dissipation capacity of FRP-RC beam-column joints.
引用
收藏
页数:12
相关论文
共 44 条
  • [1] Axial Capacity of Circular Concrete Columns Reinforced with GFRP Bars and Spirals
    Afifi, Mohammad Z.
    Mohamed, Hamdy M.
    Benmokrane, Brahim
    [J]. JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2014, 18 (01)
  • [2] [Anonymous], 2017, Design and construction of building structures with fibre-reinforced polymer
  • [3] [Anonymous], 2020, GB50608
  • [4] [Anonymous], 2015, 4401R15 ACI
  • [5] [Anonymous], 2002, C469 ASTM
  • [6] [Anonymous], 2015, D3039 ASTM
  • [7] [Anonymous], 2012, ACI 440.3R-12
  • [8] Behavior and Modeling of Concrete Confined with FRP Composites of Large Deformability
    Dai, Jian-Guo
    Bai, Yu-Lei
    Teng, J. G.
    [J]. JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2011, 15 (06) : 963 - 973
  • [9] Axial compressive behavior of square concrete columns reinforced with innovative closed-type winding GFRP stirrups
    Dong, Heng-Lei
    Wang, Daiyu
    Wang, Zhenyu
    Sun, Yunlong
    [J]. COMPOSITE STRUCTURES, 2018, 192 : 115 - 125
  • [10] Long-Term Bond Durability of Fiber-Reinforced Polymer Bars Embedded in Seawater Sea-Sand Concrete under Ocean Environments
    Dong, Zhi-Qiang
    Wu, Gang
    Zhao, Xiao-Ling
    Lian, Jin-Long
    [J]. JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2018, 22 (05)