A ratiometric approach for pH optosensing with a single fluorophore indicator

被引:25
作者
Sánchez-Barragán, I
Costa-Fernández, JM
Sanz-Medel, A
Valledor, M
Ferrero, FJ
Campo, JC
机构
[1] Univ Oviedo, Dept Elect Elect Comp & Syst Engn, Gijon 33204, Spain
[2] Univ Oviedo, Dept Phys & Analyt Chem, E-33006 Oviedo, Spain
关键词
pH sensing; ratiometric measurements; fluorescence; reflectance; sol-gel technology;
D O I
10.1016/j.aca.2006.01.033
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new fiber-optic prototype of luminometer has been designed in order to perform ratiometric-based measurements for optical sensing purposes. The coupling of a pH-selective sensing phase to the fiber-optic prototype has been evaluated for robust pH optosensing in drinking water. The pH-sensitive material has been synthesized by entrapping a pH-sensitive luminescent indicator (mercurochrome) in a sol-gel inorganic matrix. The pH optosensing is based on the detection of pH-induced reversible changes in the mercurochrome fluorescent emission and in the light reflected by the sensing phase. The instrument has been constructed using low-cost and simple optoelectronic components. The active phase was excited by means of a visible 470 nm high intensity light emitting diode (LED). The radiant power of the LED was modulated using a sinusoidal function so that scattered light due to light sources of different frequency than the modulating signal (e.g. sunlight) can be easily removed by adequate electronic filtering of the emission signal. Both the fluorescence emission from the dye and the sensing phase reflected light were collected in a bifurcated fiber-optic to allow the ratiometric measurement. Two different ratiometric approaches have been evaluated. The analytical performance of the pH optrode using both measurement methods have been compared, between them and with simple fluorescence intensity measurements, in terms of sensitivity, measurement range, response time, repeatability and insensitivity to changes in excitation light intensity. The applicability of the developed pH optrode and methods has been tested for pH analysis in tap and bottled still mineral water samples. The results obtained showed good agreement with the corresponding pH values provided by a commercial glass electrode. In this work, pH was selected as a model analyte to evaluate the performance of the proposed methodology, although other optical sensors for different applications/analytes could benefit of this approach. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:197 / 203
页数:7
相关论文
共 21 条
[1]   Narrow-range optical pH sensors based on luminescent europium and terbium complexes immobilized in a sol gel glass [J].
Blair, S ;
Lowe, MP ;
Mathieu, CE ;
Parker, D ;
Senanayake, PK ;
Kataky, R .
INORGANIC CHEMISTRY, 2001, 40 (23) :5860-5867
[2]   Stability of new optical pH sensing material based on cross-linked poly(vinyl alcohol) copolymer [J].
Cajlakovic, M ;
Lobnik, A ;
Werner, T .
ANALYTICA CHIMICA ACTA, 2002, 455 (02) :207-213
[3]   High-acidity determination in salt-containing acids by optical sensors. The scope of a dual-transducer approach and the Hammett acidity function [J].
Canada, TA ;
Allain, LR ;
Beach, DB ;
Xue, ZL .
ANALYTICAL CHEMISTRY, 2002, 74 (11) :2535-2540
[4]   An efficient fluorescent probe for ratiometric pH measurements in aqueous solutions [J].
Charier, S ;
Ruel, O ;
Baudin, JB ;
Alcor, D ;
Allemand, JF ;
Meglio, A ;
Jullien, L .
ANGEWANDTE CHEMIE-INTERNATIONAL EDITION, 2004, 43 (36) :4785-4788
[5]   Air moisture sensing materials based on the room temperature phosphorescence quenching of immobilized mercurochrome [J].
Costa-Fernández, JM ;
Sanz-Medel, A .
ANALYTICA CHIMICA ACTA, 2000, 407 (1-2) :61-69
[6]   Synthesis of a new water-soluble polymeric probe and its fluorescent properties for ratiometric measurement of near-neutral pH [J].
Dong, SY ;
Ma, HM ;
Li, XH ;
Sun, M ;
Duan, XJ .
ANALYTICAL LETTERS, 2004, 37 (14) :2937-2948
[7]   A sol-gel based fiber optic sensor for local blood pH measurements [J].
Grant, SA ;
Glass, RS .
SENSORS AND ACTUATORS B-CHEMICAL, 1997, 45 (01) :35-42
[8]   Room temperature phosphorescence pH optosensor based on energy transfer [J].
Jin, WJ ;
Costa-Fernández, JM ;
Sanz-Medel, A .
ANALYTICA CHIMICA ACTA, 2001, 431 (01) :1-9
[9]   Rapid method for the preparation of a robust optical pH sensor [J].
Kermis, HR ;
Kostov, Y ;
Rao, G .
ANALYST, 2003, 128 (09) :1181-1186
[10]   Ratiometric sensing using dual-frequency lifetime discrimination [J].
Kostov, Y ;
Harms, P ;
Rao, G .
ANALYTICAL BIOCHEMISTRY, 2001, 297 (01) :105-108