Analysis of "Accuracy of a 14-Day Factory Calibrated Continuous Glucose Monitoring System With Advanced Algorithm in Pediatric and Adult Population With Diabetes"

被引:3
作者
Kompala, Tejaswi [1 ]
Neinstein, Aaron B. [1 ,2 ]
机构
[1] Univ Calif San Francisco, Dept Med, San Francisco, CA 94143 USA
[2] Univ Calif San Francisco, Ctr Digital Hlth Innovat, San Francisco, CA 94143 USA
来源
JOURNAL OF DIABETES SCIENCE AND TECHNOLOGY | 2022年 / 16卷 / 01期
关键词
continuous glucose monitoring; diabetes mellitus; telehealth; digital health; ACCEPTABILITY; CARE;
D O I
10.1177/1932296820967004
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
In this study by Alva et al, accuracy of a second-generation factory calibrated continuous glucose monitoring system is evaluated. Compared to the first-generation FreeStyle Libre 14-day system (FSL), accuracy was improved throughout the 14-day wear period, including improved accuracy in hypoglycemia for adults and youth. The addition of optional real-time alerts for hypoglycemia and hyperglycemia as well as an integrated continuous glucose monitor (iCGM) designation by the FDA may further enable users to benefit from using CGM in real time, including in future automated insulin delivery systems. As CGM accuracy, affordability, and accessibility improve, we anticipate increased uptake of CGM by people on intensive insulin therapy, and also potential benefits and expansion into a broader patient population. There are growing opportunities to leverage cloud-connected CGM devices in the increasingly virtual, continuous telehealth-driven diabetes care model, which will require more focus on development and use of data interoperability standards.
引用
收藏
页码:78 / 80
页数:3
相关论文
共 34 条
  • [21] Budget impact analysis of the freestyle libre flash continuous glucose monitoring system® in patients with diabetes mellitus type 1 in Chile
    Palacios, Alfredo
    Cairoli, Federico Rodriguez
    Balan, Dario
    Balmaceda, Carlos
    Augustovski, Federico
    Pichon-Riviere, Andres
    Bardach, Ariel
    EXPERT REVIEW OF PHARMACOECONOMICS & OUTCOMES RESEARCH, 2023, 23 (03) : 353 - 363
  • [22] Long-term glycemic control and glucose variability assessed with continuous glucose monitoring in a pediatric population with type 1 diabetes: Determination of optimal sampling duration
    Piona, Claudia
    Marigliano, Marco
    Mozzillo, Enza
    Franzese, Adriana
    Zanfardino, Angela
    Iafusco, Dario
    Maltoni, Giulio
    Zucchini, Stefano
    Delvecchio, Maurizio
    Maffeis, Claudio
    PEDIATRIC DIABETES, 2020, 21 (08) : 1485 - 1492
  • [23] CONTINUOUS GLUCOSE MONITORING AND TYPE 1 DIABETES MELLITUS CONTROL IN CHILD , ADOLESCENT AND YOUNG ADULT POPULATION - ARGUMENTS FOR ITS USE AND EFFECTS
    Rubelj, Karla
    Stipancic, Gordana
    Sabolic, Lavinia La Grasta
    Sepec, Marija Pozgaj
    ACTA CLINICA CROATICA, 2021, 60 (04) : 609 - 616
  • [24] Does Current Diabetes Technology Improve Metabolic Control? A Cross-Sectional Study on the Use of Insulin Pumps and Continuous Glucose Monitoring Devices in a Nationwide Pediatric Population
    Bratke, Heiko
    Margeirsdottir, Hanna D.
    Assmus, Jorg
    Njolstad, Pal R.
    Skrivarhaug, Torild
    DIABETES THERAPY, 2021, 12 (09) : 2571 - 2583
  • [25] Does Current Diabetes Technology Improve Metabolic Control? A Cross-Sectional Study on the Use of Insulin Pumps and Continuous Glucose Monitoring Devices in a Nationwide Pediatric Population
    Heiko Bratke
    Hanna D. Margeirsdottir
    Jörg Assmus
    Pål R. Njølstad
    Torild Skrivarhaug
    Diabetes Therapy, 2021, 12 : 2571 - 2583
  • [26] Continuous Glucose Monitoring System in children with type 1 diabetes mellitus: a systematic review and meta-analysis
    Golicki, D. T.
    Golicka, D.
    Groele, L.
    Pankowska, E.
    DIABETOLOGIA, 2008, 51 (02) : 233 - 240
  • [27] Continuous Glucose Monitoring System in children with type 1 diabetes mellitus: a systematic review and meta-analysis
    D. T. Golicki
    D. Golicka
    L. Groele
    E. Pankowska
    Diabetologia, 2008, 51 : 233 - 240
  • [28] REAL-WORLD OBSERVATIONAL STUDY REGARDING GLUCOSE CONTROL IN INSULIN TREATED DIABETES MELLITUS PATIENTS. GLUCOSE VARIABILITY PATTERNS ANALYSIS USING CONTINUOUS GLUCOSE MONITORING SYSTEM (CGMS)
    Popoviciu, Mihaela Simona
    Vesa, Cosmin
    Jurca, Aurora
    Jurca, Claudia
    Popa, Loredana
    Zaha, Dana
    Ceavoi, Gabriela
    Jurca, Alexandru
    FARMACIA, 2021, 69 (02) : 332 - 340
  • [29] First assessment of the performance of an implantable continuous glucose monitoring system through 180 days in a primarily adolescent population with type 1 diabetes
    Aronson, Ronnie
    Abitbol, Alexander
    Tweden, Katherine S.
    DIABETES OBESITY & METABOLISM, 2019, 21 (07) : 1689 - 1694
  • [30] The use of continuous glucose monitoring systems in a pediatric population with type 1 diabetes mellitus in real-life settings: the AWeSoMe Study Group experience
    Rachmiel, M.
    Landau, Z.
    Boaz, M.
    Aronovitch, K. Mazor
    Loewenthal, N.
    Ben-Ami, M.
    Levy-Shraga, Y.
    Modan-Moses, D.
    Haim, A.
    Abiri, S.
    Pinhas-Hamiel, O.
    ACTA DIABETOLOGICA, 2015, 52 (02) : 323 - 329