Hybrid image visualization tool for 3D integration of CT coronary anatomy and quantitative myocardial perfusion PET

被引:3
|
作者
Marinelli, Martina [1 ]
Positano, Vincenzo [2 ]
Nekolla, Stephan G. [3 ]
Marcheschi, Paolo [2 ]
Todiere, Giancarlo [2 ]
Esposito, Natalia [1 ]
Puzzuoli, Stefano [1 ]
L'Abbate, Giuseppe A. [2 ]
Marraccini, Paolo [1 ]
Neglia, Danilo [1 ,2 ]
机构
[1] CNR, Inst Clin Physiol, I-56124 Pisa, Italy
[2] CNR Reg Toscana, Fdn Gabriele Monasterio, I-56124 Pisa, Italy
[3] Tech Univ Munich, Nukl Med Klin, D-81675 Munich, Germany
关键词
CAD; Hybrid imaging; Myocardial flow reserve; XML; 3D visualization; MAGNETIC-RESONANCE; DIAGNOSTIC PERFORMANCE; REGISTRATION; ANGIOGRAPHY; VIABILITY; HEART; SUM;
D O I
10.1007/s11548-012-0777-3
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Multimodal cardiac imaging by CTA and quantitative PET enables acquisition of patient-specific coronary anatomy and absolute myocardial perfusion at rest and during stress. In the clinical setting, integration of this information is performed visually or using coronary arteries distribution models. We developed a new tool for CTA and quantitative PET integrated 3D visualization, exploiting XML and DICOM clinical standards. The hybrid image tool (HIT) developed in the present study included four main modules: (1) volumetric registration for spatial matching of CTA and PET data sets, (2) an interface to PET quantitative analysis software, (3) a derived DICOM generator able to build DICOM data set from quantitative polar maps, and (4) a 3D visualization tool of integrated anatomical and quantitative flow information. The four modules incorporated in the HIT tool communicate by defined standard XML files: XML-transformation and XML MIST standards. The HIT tool implements a 3D representation of CTA showing real coronary anatomy fused to PET-derived quantitative myocardial blood flow distribution. The technique was validated on 16 data sets from EVINCI study population. The validation of the method confirmed the high matching between "original" and derived data sets as well as the accuracy of the registration procedure. Three-dimensional integration of patient- specific coronary artery anatomy provided by CTA and quantitative myocardial blood flow obtained from PET imaging can improve cardiac disease assessment. The HIT tool introduced in this paper may represent a significant advancement in the clinical use of this multimodal approach.
引用
收藏
页码:221 / 232
页数:12
相关论文
共 27 条
  • [21] Fusion of CT coronary angiography and whole-heart dynamic 3D cardiac MR perfusion: building a framework for comprehensive cardiac imaging
    Jochen von Spiczak
    Robert Manka
    Alexander Gotschy
    Sabrina Oebel
    Sebastian Kozerke
    Sandra Hamada
    Hatem Alkadhi
    The International Journal of Cardiovascular Imaging, 2018, 34 : 649 - 660
  • [22] Image quality of Adaptive Iterative Dose Reduction 3D of coronary CT angiography of 640-slice CT: comparison with filtered back-projection
    Yoo, Roh-Eul
    Park, Eun-Ah
    Lee, Whal
    Shim, Hackjoon
    Kim, Yeo Koon
    Chung, Jin Wook
    Park, Jae Hyung
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2013, 29 (03) : 669 - 676
  • [23] Coronary artery calcium burden, carotid atherosclerotic plaque burden, and myocardial blood flow in patients with end-stage renal disease: A non-invasive imaging study combining PET/CT and 3D ultrasound
    Wenning, Christian
    Vrachimis, Alexis
    Pavenstadt, Hermann-Joseph
    Reuter, Stefan
    Schafers, Michael
    JOURNAL OF NUCLEAR CARDIOLOGY, 2021, 28 (06) : 2660 - 2670
  • [24] Cross-institutional validation of a polar map-free 3D deep learning model for obstructive coronary artery disease prediction using myocardial perfusion imaging: insights into generalizability and bias
    Shih, Yu-Cheng
    Ko, Chi-Lun
    Wang, Shan-Ying
    Chang, Chen-Yu
    Lin, Shau-Syuan
    Huang, Cheng-Wen
    Cheng, Mei-Fang
    Chen, Chung-Ming
    Wu, Yen-Wen
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2025,
  • [25] 3D quantitative myocardial perfusion imaging with hyperpolarized HP001(bis-1,1-(hydroxymethyl)-[1-13C]cyclopropane-d8): Application of gradient echo and balanced SSFP sequences
    Zhao, Yupeng
    Olin, Rie Beck
    Hansen, Esben Svs Szocska
    Laustsen, Christoffer
    Hanson, Lars G.
    Ardenkjaer-Larsen, Jan Henrik
    MAGNETIC RESONANCE IN MEDICINE, 2025, 93 (02) : 814 - 827
  • [27] The Minimal Ablative Margin of Radiofrequency Ablation of Hepatocellular Carcinoma (> 2 and < 5 cm) Needed to Prevent Local Tumor Progression: 3D Quantitative Assessment Using CT Image Fusion
    Kim, Young-sun
    Lee, Won Jae
    Rhim, Hyunchul
    Lim, Hyo K.
    Choi, Dongil
    Lee, Ji Young
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 195 (03) : 758 - 765