Exergetic Evaluation of an Ethylene Refrigeration Cycle

被引:2
作者
Amaral, Francisco [1 ]
Santos, Alex [2 ]
Calixto, Ewerton [2 ]
Pessoa, Fernando [2 ]
Santana, Delano [3 ]
机构
[1] Braskem, Rua Eteno, BR-42816200 Camacari, BA, Brazil
[2] Univ Ctr SENAI CIMATEC, Computat Modeling Dept, BR-41650010 Salvador, BA, Brazil
[3] Univ Fed Bahia, Dept Chem Engn, BR-40210630 Salvador, BA, Brazil
关键词
exergy; refrigeration cycles; process monitoring; CENTRIFUGAL COMPRESSORS; ENERGY; SYSTEM; OPTIMIZATION;
D O I
10.3390/en13143753
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The production of light olefins by selective steam cracking is an energy-intensive process, and ethylene and propylene refrigeration cycles are key parts of it. The objective of this study was to identify opportunities for energy savings in an ethylene refrigeration cycle through an exergetic analysis. Two main causes of lower operational efficiency were identified: (1) Lower polytropic efficiency of the refrigerant compressor and (2) operating with the compressor mini-flow valve open to ensure reliability. The evaluation showed that the amount of irreversibilities generated by the cycle in operation is 22% higher than that predicted by the original design, which represents a 14% lower exergy efficiency. There is a potential savings of 0.20 MW in the cycle's energy consumption with the implementation of the following improvements: recover refrigerant compressor efficiency by performing maintenance on the equipment and optimize the flow distribution between the recycle valve, the level control valve, and the temperature control valve.
引用
收藏
页数:21
相关论文
共 28 条
[1]   A review on exergy analysis of vapor compression refrigeration system [J].
Ahamed, J. U. ;
Saidur, R. ;
Masjuki, H. H. .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2011, 15 (03) :1593-1600
[2]  
[Anonymous], 2007, 3LSEVIER SCI
[3]  
[Anonymous], 2001, CHEM PETROCHEMICAL P
[4]   Predicting performance of refrigerants using the Peng-Robinson Equation of State [J].
Brown, J. Steven .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2007, 30 (08) :1319-1328
[5]   Energy Evaluation of Multiple Stage Commercial Refrigeration Architectures Adapted to F-Gas Regulation [J].
Catalan-Gil, Jesus ;
Sanchez, Daniel ;
Llopis, Rodrigo ;
Nebot-Andres, Laura ;
Cabello, Ramon .
ENERGIES, 2018, 11 (07)
[6]   First and Second Law Analyses of Trans-critical N2O Refrigeration Cycle Using an Ejector [J].
Dokandari, Damoon Aghazadeh ;
Mahmoudi, S. M. S. ;
Bidi, M. ;
Khoshkhoo, Ramin Haghighi ;
Rosen, Marc A. .
SUSTAINABILITY, 2018, 10 (04)
[7]   Exergetic analysis of the refrigeration system in ethylene and propylene production process [J].
Fabrega, F. M. ;
Rossi, J. S. ;
d'Angelo, J. V. H. .
ENERGY, 2010, 35 (03) :1224-1231
[8]  
Fuentes A., BRASIL PIORA RANKING
[9]   Exergy analysis as a scoping tool for cleaner production of chemicals: a case study of an ethylene production process [J].
Ghannadzadeh, Ali ;
Sadeqzadeh, Majid .
JOURNAL OF CLEANER PRODUCTION, 2016, 129 :508-520
[10]   Advanced Thermodynamic Analysis of a Transcritical R744 Booster Refrigerating Unit with Dedicated Mechanical Subcooling [J].
Gullo, Paride .
ENERGIES, 2018, 11 (11)