Optimization of high-resolution continuum source graphite furnace atomic absorption spectrometry for direct analysis of selected trace elements in whole blood samples

被引:16
作者
Wojciak-Kosior, Magdalena [1 ]
Szwerc, Wojciech [1 ]
Strzemski, Maciej [1 ]
Wichlacz, Zoltan [1 ]
Sawicki, Jan [1 ]
Kocjan, Ryszard [1 ]
Latalski, Michal [2 ]
Sowa, Ireneusz [1 ]
机构
[1] Med Univ Lublin, Dept Analyt Chem, Chodzki 4a, PL-20093 Lublin, Poland
[2] Med Univ Lublin, Childrens Orthoped Dept, Gebali 6, PL-20093 Lublin, Poland
关键词
High resolution continuum source GF-AAS; Trace element analysis; Whole blood; INDUCTIVELY-COUPLED PLASMA; MASS-SPECTROMETRY; GF AAS; LEAD; PB; SELENIUM; SILICON; LITHIUM; URINE; NI;
D O I
10.1016/j.talanta.2016.12.077
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Trace analysis plays an important role in medicine for diagnosis of various disorders; however, the appropriate sample preparation is required mostly including mineralization. Although graphite furnace atomic absorption spectrometry (GF AAS) allows the investigation of biological samples such as blood, serum, and plasma without this step, it is rarely used for direct analysis because the residues of the rich organic matrix inside the furnace are difficult to remove and this may cause spectral/matrix interferences and decrease the lifetime of the graphite tube. In our work, the procedure for determination of Se, Cr, Mn, Co, Ni, Cd and Pb with the use of the high resolution continuum source GF-AAS technique in whole blood samples with minimum sample pre-treatment was elaborated. The pyrolysis and atomization temperature as well as the time of signal integration were optimized to obtain the highest intensity and repeatability of the analytical signal. Moreover, due to the apparatus modification, an additional step was added in the for graphite furnace temperature program with minimal argon flow and maximal flow of air during pyrolysis stage to increase the oxidative condition for better matrix removal. The accuracy and precision of the optimized method was verified using certified reference material (CRM) Seronorm Trace Elements Whole Blood L-1 and the developed method was applied for trace analysis of blood samples from volunteer patients of the Orthopedics Department.
引用
收藏
页码:351 / 356
页数:6
相关论文
共 31 条
[11]   Biomonitoring of 20 trace elements in blood and urine of occupationally exposed workers by sector field inductively coupled plasma mass spectrometry [J].
Ivanenko, N. B. ;
Ivanenko, A. A. ;
Solovyev, N. D. ;
Zeimal', A. E. ;
Navolotskii, D. V. ;
Drobyshev, E. J. .
TALANTA, 2013, 116 :764-769
[12]   Determination of Pb in glasses by direct solid sampling and high-resolution continuum source graphite furnace atomic absorption spectrometry: method development and analyses of glass samples [J].
Kelestemur, Seda ;
Ozcan, Mustafa .
MICROCHEMICAL JOURNAL, 2015, 118 :55-61
[13]   Determination of macro and trace elements in multivitamin dietary supplements by high-resolution continuum source graphite furnace atomic absorption spectrometry with slurry sampling [J].
Krawczyk, Magdalena .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2014, 88 :377-384
[14]   Solid sampling determination of lithium and sodium additives in microsamples of yttrium oxyorthosilicate by high-resolution continuum source graphite furnace atomic absorption spectrometry [J].
Laczai, Nikoletta ;
Kovacs, Laszlo ;
Peter, Agnes ;
Bencs, Laszlo .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2016, 117 :8-15
[15]   Determination of Cu2+ Zn2+ and Pb2+ in biological and food samples by FAAS after preconcentration with hydroxyapatite nanorods originated from eggshell [J].
Mortada, Wael I. ;
Kenawy, Ibrahim M. M. ;
Abdelghany, Amr M. ;
Ismal, Amani M. ;
Donia, Ahmed F. ;
Nabieh, Kareem A. .
MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2015, 52 :288-296
[16]   Atomic spectrometry and trends in clinical laboratory medicine [J].
Parsons, Patrick J. ;
Barbosa, Fernando, Jr. .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2007, 62 (09) :992-1003
[17]   Investigation of chemical modifiers for the direct determination of arsenic in fish oil using high-resolution continuum source graphite furnace atomic absorption spectrometry [J].
Pereira, Ederson R. ;
de Almeida, Tarcisio S. ;
Borges, Daniel L. G. ;
Carasek, Eduardo ;
Welz, Bernhard ;
Feldmann, Joerg ;
del Campo Menoyo, Javier .
TALANTA, 2016, 150 :142-147
[18]   Determination of lead in medicinal plants by high-resolution continuum source graphite furnace atomic absorption spectrometry using direct solid sampling [J].
Rego, Jardes Figueredo ;
Virgilio, Alex ;
Nobrega, Joaquim A. ;
Gomes Neto, Jose A. .
TALANTA, 2012, 100 :21-26
[19]   Direct determination of phosphorus in two different plastic materials (PET and PP) by solid sampling-graphite furnace atomic absorption spectrometry [J].
Resano, M ;
Belarra, MA ;
Castillo, JR ;
Vanhaecke, F .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2000, 15 (10) :1383-1388
[20]   Simultaneous determination of Co, Fe, Ni and Pb in carbon nanotubes by means of solid sampling high-resolution continuum source graphite furnace atomic absorption spectrometry [J].
Resano, Martin ;
Bolea-Fernandez, Eduardo ;
Mozas, Engracia ;
Florez, Maria R. ;
Grinberg, Patricia ;
Sturgeon, Ralph E. .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2013, 28 (05) :657-665