Optimization of high-resolution continuum source graphite furnace atomic absorption spectrometry for direct analysis of selected trace elements in whole blood samples

被引:16
作者
Wojciak-Kosior, Magdalena [1 ]
Szwerc, Wojciech [1 ]
Strzemski, Maciej [1 ]
Wichlacz, Zoltan [1 ]
Sawicki, Jan [1 ]
Kocjan, Ryszard [1 ]
Latalski, Michal [2 ]
Sowa, Ireneusz [1 ]
机构
[1] Med Univ Lublin, Dept Analyt Chem, Chodzki 4a, PL-20093 Lublin, Poland
[2] Med Univ Lublin, Childrens Orthoped Dept, Gebali 6, PL-20093 Lublin, Poland
关键词
High resolution continuum source GF-AAS; Trace element analysis; Whole blood; INDUCTIVELY-COUPLED PLASMA; MASS-SPECTROMETRY; GF AAS; LEAD; PB; SELENIUM; SILICON; LITHIUM; URINE; NI;
D O I
10.1016/j.talanta.2016.12.077
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Trace analysis plays an important role in medicine for diagnosis of various disorders; however, the appropriate sample preparation is required mostly including mineralization. Although graphite furnace atomic absorption spectrometry (GF AAS) allows the investigation of biological samples such as blood, serum, and plasma without this step, it is rarely used for direct analysis because the residues of the rich organic matrix inside the furnace are difficult to remove and this may cause spectral/matrix interferences and decrease the lifetime of the graphite tube. In our work, the procedure for determination of Se, Cr, Mn, Co, Ni, Cd and Pb with the use of the high resolution continuum source GF-AAS technique in whole blood samples with minimum sample pre-treatment was elaborated. The pyrolysis and atomization temperature as well as the time of signal integration were optimized to obtain the highest intensity and repeatability of the analytical signal. Moreover, due to the apparatus modification, an additional step was added in the for graphite furnace temperature program with minimal argon flow and maximal flow of air during pyrolysis stage to increase the oxidative condition for better matrix removal. The accuracy and precision of the optimized method was verified using certified reference material (CRM) Seronorm Trace Elements Whole Blood L-1 and the developed method was applied for trace analysis of blood samples from volunteer patients of the Orthopedics Department.
引用
收藏
页码:351 / 356
页数:6
相关论文
共 31 条
[1]   Inductively coupled plasma - Tandem mass spectrometry (ICP-MS/MS): A powerful and universal tool for the interference-free determination of (ultra) trace elements - A tutorial review [J].
Balcaen, Lieve ;
Bolea-Fernandez, Eduardo ;
Resano, Martin ;
Vanhaecke, Frank .
ANALYTICA CHIMICA ACTA, 2015, 894 :7-19
[2]   Determination of trace elements in lithium niobate crystals by solid sampling and solution-based spectrometry methods [J].
Bencs, Laszlo ;
Gyoergy, Krisztina ;
Kardos, Marta ;
Osan, Janos ;
Alfoeldy, Balint ;
Varga, Imre ;
Ajtony, Zsolt ;
Szoboszlai, Norbert ;
Stefanka, Zsolt ;
Szeles, Eva ;
Kovacs, Laszlo .
ANALYTICA CHIMICA ACTA, 2012, 726 :1-8
[3]   Development of a method for the sequential determination of cadmium and chromium from the same sample aliquot of yerba mate using high-resolution continuum source graphite furnace atomic absorption spectrometry [J].
Borges, Aline R. ;
Bazanella, Debora N. ;
Duarte, Alvaro Tavares ;
Zmozinski, Ariane V. ;
Vale, Maria Goreti R. ;
Welz, Bernhard .
MICROCHEMICAL JOURNAL, 2017, 130 :116-121
[4]   Determination of silicon in plant materials using direct solid sample analysis with high-resolution continuum source graphite furnace atomic absorption spectrometry [J].
Boschetti, Wiliam ;
Dalagnol, Luiza M. G. ;
Dullius, Mariana ;
Zmozinski, Ariane V. ;
Becker, Emilene M. ;
Vale, Maria Goreti R. ;
de Andrade, Jailson B. .
MICROCHEMICAL JOURNAL, 2016, 124 :380-385
[5]   Determination of mercury in biological samples using solid sampling high-resolution continuum source electrothermal atomization atomic absorption spectrometry with calibration against aqueous standards [J].
da Silva, Alessandra Furtado ;
Lepri, Fabio Grandis ;
Borges, Daniel L. Gallindo ;
Welz, Bernhard ;
Curtius, Adilson J. ;
Heitmann, Uwe .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2006, 21 (11) :1321-1326
[6]   Direct determination of tin in whole blood and urine by GF AAS [J].
De Azevedo, S. V. ;
Moreira, F. R. ;
Campos, R. C. .
CLINICAL BIOCHEMISTRY, 2013, 46 (1-2) :123-127
[7]   Determination of trace impurities in titanium dioxide by direct solid sampling electrothermal atomic absorption spectrometry [J].
Docekal, Bohumil ;
Vojtkova, Blanka .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2007, 62 (03) :304-308
[8]   Determination of lead in biomass and products of the pyrolysis process by direct solid or liquid sample analysis using HR-CS GF AAS [J].
Duarte, Alvaro T. ;
Borges, Aline R. ;
Zmozinski, Ariane V. ;
Dessuy, Morgana B. ;
Welz, Bernhard ;
de Andrade, Jailson B. ;
Vale, Maria Goreti R. .
TALANTA, 2016, 146 :166-174
[9]  
Elsherif K. M., 2013, ACTA CHIM PHARM INDI, V3, P241
[10]   A direct solid sampling electrothermal atomic absorption spectrometry method for the determination of silicon in biological materials [J].
Huang, M. D. ;
Krivan, V. .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2007, 62 (03) :297-303