RF Surface Receive Array Coils: The Art of an LC Circuit

被引:47
作者
Fujita, Hiroyuki [1 ,2 ,3 ,4 ]
Zheng, Tsinghua [1 ]
Yang, Xiaoyu [1 ]
Finnerty, Matthew J. [1 ]
Handa, Shinya [1 ]
机构
[1] Qual Electrodynam QED, Mayfield Village, OH 44143 USA
[2] Case Western Reserve Univ, Dept Phys, Cleveland, OH 44106 USA
[3] Univ Hosp Cleveland, Dept Radiol, Cleveland, OH 44106 USA
[4] Univ Queensland, Sch Informat Technol & Elect Engn, Brisbane, Qld, Australia
基金
美国国家卫生研究院;
关键词
RF coil; RF array coil; preamplifier; decoupling; balun; TO-NOISE RATIO; NUCLEAR-MAGNETIC-RESONANCE; PHASED-ARRAY; RADIOFREQUENCY COIL; CARDIAC COIL; 7; TESLA; MRI; DESIGN; NMR; PREAMPLIFIERS;
D O I
10.1002/jmri.24159
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The radiofrequency (RF) receive array coil is a complicated device with many inductors and capacitors and serves as one of the most critical magnetic resonance imaging (MRI) electronic devices. It directly determines the achievable level of signal-to-noise ratio (SNR). Simply put, however, the RF coil is nothing but an LC circuit. The receive array coil was first proposed more than 20 years ago, evolving from a simple arrangement with a few electronic channels to a complicated system of 128 channels, enabling highly sophisticated parallel imaging, at different field strengths. This article summarizes the basic concepts pertaining to RF receive coil arrays and their associated SNR and reviews the theories behind the major components of such arrays. This includes discussions of the intrinsic SNR of a receive coil, the matching circuits, low-noise preamplifiers, coupling/decoupling amongst coils, the coupling between receive and transmit coils, decoupling via preamplifiers, and baluns. An 8-channel receive array coil on a cylindrical former serves as a useful example for demonstrating various points in the review. J. Magn. Reson. Imaging 2013;38:12-25. (c) 2013 Wiley Periodicals, Inc.
引用
收藏
页码:12 / 25
页数:14
相关论文
共 61 条
[1]   A 32-Channel Lattice Transmission Line Array for Parallel Transmit and Receive MRI at 7 Tesla [J].
Adriany, Gregor ;
Auerbach, Edward J. ;
Snyder, Carl J. ;
Gozubuyuk, Ark ;
Moeller, Steen ;
Ritter, Johannes ;
Van de Moortele, Pierre-Francois ;
Vaughan, Tommy ;
Ugurbil, Kamil .
MAGNETIC RESONANCE IN MEDICINE, 2010, 63 (06) :1478-1485
[2]   ELIMINATION OF COUPLING BETWEEN CYLINDRICAL TRANSMIT COILS AND SURFACE-RECEIVE COILS FOR INVIVO NMR [J].
BENDALL, MR ;
CONNELLY, A ;
MCKENDRY, JM .
MAGNETIC RESONANCE IN MEDICINE, 1986, 3 (01) :157-163
[3]  
BOSKAMP EB, 2005, P 13 ANN M ISMRM MIA
[4]  
Boskamp EB, 2007, P 15 ANN M ISMRM BER
[5]   Travelling-wave nuclear magnetic resonance [J].
Brunner, David O. ;
De Zanche, Nicola ;
Froehlich, Juerg ;
Paska, Jan ;
Pruessmann, Klaas P. .
NATURE, 2009, 457 (7232) :994-U2
[6]   Comparison of a 28-channel receive array coil and quadrature volume coil for morphologic imaging and T2 mapping of knee cartilage at 7T [J].
Chang, Gregory ;
Wiggins, Graham C. ;
Xia, Ding ;
Lattanzi, Riccardo ;
Madelin, Guillaume ;
Raya, Jose G. ;
Finnerty, Matthew ;
Fujita, Hiroyuki ;
Recht, Michael P. ;
Regatte, Ravinder R. .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2012, 35 (02) :441-448
[7]  
Chen CN, 1989, BIOMEDICAL MAGNETIC, P136
[8]   Modular design of receiver coil arrays [J].
De Zanche, Nicola ;
Massner, Jurek A. ;
Leussler, Christoph ;
Pruessmann, Klaas P. .
NMR IN BIOMEDICINE, 2008, 21 (06) :644-654
[9]  
Finnerty MJ, 2010, P 18 ANN M ISMRM STO
[10]   COUNTER ROTATING CURRENT LOCAL COILS FOR HIGH-RESOLUTION MAGNETIC-RESONANCE-IMAGING [J].
FRONCISZ, W ;
JESMANOWICZ, A ;
KNEELAND, JB ;
HYDE, JS .
MAGNETIC RESONANCE IN MEDICINE, 1986, 3 (04) :590-603