INFLUENCE OF GAP SHAPE ON BIOMECHANICAL PROPERTIES OF EXTRA-ARTICULAR DISTAL HUMERAL FRACTURE - A FINITE ELEMENT STUDY

被引:1
作者
Sabalic, Srecko [1 ]
Maricic, Hrvoje [2 ]
Tomicevic, Zvonimir [2 ]
Kodvanj, Janos [2 ]
机构
[1] Sestre Milosrdnice Univ, Ctr Hosp, Univ Hosp Traumatol, Zagreb, Croatia
[2] Univ Zagreb, Fac Mech Engn & Naval Architecture, Zagreb, Croatia
关键词
Humeral fractures; surgery; Fracture fixation; internal; Biomechanical phenomena; Finite element analysis; Bone plates; INTERNAL-FIXATION; RECONSTRUCTION PLATES; SURGICAL-TREATMENT; FOLLOW-UP; OSTEOSYNTHESIS; PARALLEL;
D O I
10.20471/acc.2016.55.03.05
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The aim of the study was to assess the influence of gap shape on biomechanical results in extra-articular distal humeral fracture: with contact on the posterior part (by anterior gap) and contact on ulnar column (by radial gap). The goal was to examine if and to what extent did displacements decrease in comparison with previously examined parallel gap without bony contact. The finite element analysis on the three different plate constructs was performed, i.e. parallel, perpendicular and newly designed Y shape plate were considered. Displacements were measured on articular surface and gap point. The most visible decrease of maximum displacements in the distal part of the model was detected in the Y plate model with axial loading: in case of anterior gap 58.5% and especially at radially formed gap 60.9%. Similarly, at axial loading, displacement at the analyzed point on fracture gap most significantly decreased in Y plate model (by 49.4%) at posterior bony contact. Moreover, the latter showed displacement decrease by 68.5% at ulnar bone contact. Furthermore, if a longer radial plate than the ulnar one was used, varus stress could have been avoided. Study results suggested that sufficient stability could be ensured with the newly designed Y shape plate.
引用
收藏
页码:381 / 389
页数:9
相关论文
共 31 条
[1]   A biomechanical comparison of plate configuration in distal humerus fractures [J].
Arnander, Magnus W. T. ;
Reeves, Alexander ;
MacLeod, Iain A. R. ;
Pinto, Thomas M. ;
Khaleel, Arshad .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2008, 22 (05) :332-336
[2]   Advancements in the treatment of distal humeral fractures [J].
Becker, Edward H. ;
Stein, Jason .
CURRENT ORTHOPAEDIC PRACTICE, 2009, 20 (04) :345-348
[3]   Biomechanical study of different plate configurations for distal humerus osteosynthesis [J].
Bogataj, M. ;
Kosel, F. ;
Norris, R. ;
Krkovic, M. ;
Brojan, M. .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2015, 53 (05) :381-392
[4]  
DeLuise A, 2006, CURR OPIN ORTHOP, V17, P340, DOI [10.1097/01.bco.0000233730.49010.c5, DOI 10.1097/01.BCO.0000233730.49010.C5]
[5]   Three-dimensional distribution of trabecular bone density and cortical thickness in the distal humerus [J].
Diederichs, Gerd ;
Issever, Ahi-Sema ;
Greiner, Stefan ;
Linke, Berend ;
Korner, Jan .
JOURNAL OF SHOULDER AND ELBOW SURGERY, 2009, 18 (03) :399-407
[6]   TRANSMISSION OF PRESSURES ACROSS ELBOW JOINT [J].
HALLS, AA ;
TRAVILL, A .
ANATOMICAL RECORD, 1964, 150 (03) :243-&
[7]   Extra-articular distal-third diaphyseal fractures of the humerus - A comparison of functional bracing and plate fixation [J].
Jawa, Andrew ;
McCarty, Pearce ;
Doornberg, Job ;
Harris, Mitch ;
Ring, David .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2006, 88A (11) :2343-2347
[8]   A biomechanical evaluation of methods of distal humerus fracture fixation using locking compression plates versus conventional reconstruction plates [J].
Korner, J ;
Diederichs, G ;
Arzdorf, M ;
Lill, H ;
Josten, C ;
Schneider, E ;
Linke, B .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2004, 18 (05) :286-293
[9]   Surgical treatment of AO type C distal humeral fractures: Internal fixation with a Y-shaped reconstruction (Lambda) plate [J].
Luegmair, Matthias ;
Timofiev, Evelin ;
Chirpaz-Cerbat, Jean-Marie .
JOURNAL OF SHOULDER AND ELBOW SURGERY, 2008, 17 (01) :113-120
[10]  
McKee MichaelD., 2006, Rockwood and Green's Fractures in Adults, P1117