Intermediate-term outcome of 500 consecutive rapid-deployment surgical aortic valve procedures

被引:37
作者
Andreas, Martin [1 ]
Coti, Iuliana [1 ]
Rosenhek, Raphael [2 ]
Shabanian, Shiva [1 ]
Mahr, Stephane [1 ]
Uyanik-Uenal, Keziban [1 ]
Wiedemann, Dominik [1 ]
Binder, Thomas [2 ]
Kocher, Alfred [1 ]
Laufer, Guenther [1 ]
机构
[1] Med Univ Vienna, Div Cardiac Surg, Dept Surg, Waehringer Guertel 18-20, A-1090 Vienna, Austria
[2] Med Univ Vienna, Div Cardiol, Dept Internal Med 2, Vienna, Austria
关键词
Aortic valve replacement; Rapid-deployment; Transvalvular gradient; Minimally invasive surgery; HEMODYNAMIC PERFORMANCE; REPLACEMENT; TRANSCATHETER; TRIAL; BIOPROSTHESIS; IMPLANTATION; MULTICENTER; STERNOTOMY; GUIDELINES; MORTALITY;
D O I
10.1093/ejcts/ezy273
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVES The Edwards INTUITY Valve System is a balloon-expandable bioprosthesis, inspired from the Edwards Magna valve and transcatheter technology, with a subvalvular stent frame to enable rapid deployment. We report a single-centre experience of aortic valve replacement with this novel bioprosthesis. METHODS Five hundred consecutive patients, of whom 45.6% were female with a mean age of 73.5 [standard deviation (SD) 7.9years], with severe aortic stenosis who received a rapid deployment aortic valve between May 2010 and July 2017 were included in a prospective and ongoing database. The median follow-up time was 12months, and the total accumulated follow-up time was 818 patient years. Preoperative characteristics, operative parameters, survival, valve-related adverse events and valve haemodynamics were assessed. RESULTS Thirty-day mortality was 0.8% (4/500), and overall survival at 1, 3 and 5 years was 94%, 89% and 81%, respectively. A minimally invasive surgical approach was chosen in 236 patients (47%), of which 122 (24%) were operated on through an anterior right thoracotomy. Cross-clamp and cardiopulmonary bypass times for isolated aortic valve replacement were 53 (SD 17) and 89 (SD 29) min for full sternotomy as well as 75 (SD 23) and 110 (SD 31) min for minimally invasive surgery approaches (P<0.001). Mean gradients at discharge, 1, 3 and 5 years were 13 (SD 5), 11 (SD 4), 12 (SD 5) and 11 (SD 3) mmHg, respectively. New pacemaker implantation was necessary in 8.6% of patients. A single case (0.2%) of structural degeneration was registered after 6 years. Valve explantation for non-structural dysfunction or endocarditis occurred in 9 patients (1.8%). CONCLUSIONS This rapid deployment aortic valve has shown excellent results concerning haemodynamic performance, durability and safety. Implantation requires specific training, and the rate of pacemaker implantation remains a matter of concern. This novel valve also facilitates minimally invasive approaches and may be beneficial in complex combined procedures.
引用
收藏
页码:527 / 533
页数:7
相关论文
共 50 条
[41]   Conduction disorders after aortic valve replacement with rapid-deployment bioprostheses: early occurrence and one-year evolution [J].
D'Onofrio, Augusto ;
Tessari, Chiara ;
Bagozzi, Lorenzo ;
Migliore, Federico ;
Filippini, Claudia ;
Cibin, Giorgia ;
Pesce, Rita ;
Francescato, Annalisa ;
Gerosa, Gino .
ANNALS OF CARDIOTHORACIC SURGERY, 2020, 9 (05) :396-407
[42]   Promising early outcomes in surgical aortic valve replacement utilizing the rapid deployment approach for isolated aortic valve regurgitation [J].
von der Linden, Julia ;
Vlachea, Polyxeni ;
Kolos, Olesya ;
Herrmann, Florian ;
Belyaev, Sergey ;
Juchem, Gerd ;
Peterss, Sven ;
Hagl, Christian ;
Dashkevich, Alexey .
INTERDISCIPLINARY CARDIOVASCULAR AND THORACIC SURGERY, 2025, 40 (07)
[43]   Rapid-deployment aortic valve replacement in high-risk patients: A case-control study [J].
Sawadogo, Adama ;
An Vinh Bui-Duc ;
D'Ostrevy, Nicolas ;
Camilleri, Lionel ;
Azarnoush, Kasra .
JOURNAL OF CARDIOVASCULAR AND THORACIC RESEARCH, 2021, 13 (01) :23-27
[44]   Intermediate-Term Outcome of 140 Consecutive Fontan Conversions With Arrhythmia Operations [J].
Deal, Barbara J. ;
Costello, John M. ;
Webster, Gregory ;
Tsao, Sabrina ;
Backer, Carl L. ;
Mavroudis, Constantine .
ANNALS OF THORACIC SURGERY, 2016, 101 (02) :717-724
[45]   Early surgical outcomes of rapid deployment aortic valve replacement in bicuspid aortic valves [J].
Lee, June ;
Kim, Yong Han ;
Lim, Hyun Ali ;
Hong, Seok Beom ;
Kim, Do Yeon ;
Kim, Hwan Wook .
JOURNAL OF THORACIC DISEASE, 2024, 16 (09) :6171-6181
[46]   Intermediate-term outcomes of aortic valve replacement with bioprosthetic or mechanical valves in patients on hemodialysis [J].
Nakatsu, Taro ;
Minakata, Kenji ;
Tanaka, Shiro ;
Minatoya, Kenji ;
Nishizawa, Junichiro ;
Ohno, Nobuhisa ;
Esaki, Jiro ;
Ueyama, Koji ;
Koyama, Tadaaki ;
Hanyu, Michiya ;
Tamura, Nobushige ;
Komiya, Tatsuhiko ;
Saito, Yuhei ;
Kanemitsu, Naoki ;
Soga, Yoshiharu ;
Shiraga, Kotaro ;
Nakayama, Shogo ;
Nonaka, Michihito ;
Sakaguchi, Genichi ;
Nishimura, Kazunobu ;
Yamanaka, Kazuo .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2019, 157 (06) :2177-+
[47]   Rapid-deployment aortic valve replacement after aortic root replacement: A safe alternative to redo root replacement [J].
Wilder, Travis J. ;
Sharma, Vikas ;
Koliopoulou, Antigone ;
McKellar, Stephen H. ;
Selzman, Craig H. ;
Glotzbach, Jason P. .
JOURNAL OF CARDIAC SURGERY, 2020, 35 (01) :222-225
[48]   Rapid deployment aortic valve replacement in the setting of concomitant mitral valve procedures [J].
Bechtel, Matthias ;
Schloemicher, Markus ;
Moustafine, Vadim ;
Strauch, Justus Thomas .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2017, 51 (04) :792-793
[49]   A new technique that prevents paravalvular leakage after aortic valve replacement using a rapid-deployment valve system [J].
Yamamoto, Taira ;
Endo, Daisuke ;
Yamaoka, Hironobu ;
Matsushita, Satoshi ;
Kajimoto, Kan ;
Asai, Tohru ;
Amano, Atsushi .
JOURNAL OF CARDIAC SURGERY, 2021, 36 (07) :2225-2232
[50]   Rapid-Deployment Aortic Valve Replacement: Clear Benefits Without a Clear Target Patient Population [J].
Jarrett, Craig M. .
SEMINARS IN THORACIC AND CARDIOVASCULAR SURGERY, 2018, 30 (01) :24-25