Intermediate-term outcome of 500 consecutive rapid-deployment surgical aortic valve procedures

被引:37
作者
Andreas, Martin [1 ]
Coti, Iuliana [1 ]
Rosenhek, Raphael [2 ]
Shabanian, Shiva [1 ]
Mahr, Stephane [1 ]
Uyanik-Uenal, Keziban [1 ]
Wiedemann, Dominik [1 ]
Binder, Thomas [2 ]
Kocher, Alfred [1 ]
Laufer, Guenther [1 ]
机构
[1] Med Univ Vienna, Div Cardiac Surg, Dept Surg, Waehringer Guertel 18-20, A-1090 Vienna, Austria
[2] Med Univ Vienna, Div Cardiol, Dept Internal Med 2, Vienna, Austria
关键词
Aortic valve replacement; Rapid-deployment; Transvalvular gradient; Minimally invasive surgery; HEMODYNAMIC PERFORMANCE; REPLACEMENT; TRANSCATHETER; TRIAL; BIOPROSTHESIS; IMPLANTATION; MULTICENTER; STERNOTOMY; GUIDELINES; MORTALITY;
D O I
10.1093/ejcts/ezy273
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVES The Edwards INTUITY Valve System is a balloon-expandable bioprosthesis, inspired from the Edwards Magna valve and transcatheter technology, with a subvalvular stent frame to enable rapid deployment. We report a single-centre experience of aortic valve replacement with this novel bioprosthesis. METHODS Five hundred consecutive patients, of whom 45.6% were female with a mean age of 73.5 [standard deviation (SD) 7.9years], with severe aortic stenosis who received a rapid deployment aortic valve between May 2010 and July 2017 were included in a prospective and ongoing database. The median follow-up time was 12months, and the total accumulated follow-up time was 818 patient years. Preoperative characteristics, operative parameters, survival, valve-related adverse events and valve haemodynamics were assessed. RESULTS Thirty-day mortality was 0.8% (4/500), and overall survival at 1, 3 and 5 years was 94%, 89% and 81%, respectively. A minimally invasive surgical approach was chosen in 236 patients (47%), of which 122 (24%) were operated on through an anterior right thoracotomy. Cross-clamp and cardiopulmonary bypass times for isolated aortic valve replacement were 53 (SD 17) and 89 (SD 29) min for full sternotomy as well as 75 (SD 23) and 110 (SD 31) min for minimally invasive surgery approaches (P<0.001). Mean gradients at discharge, 1, 3 and 5 years were 13 (SD 5), 11 (SD 4), 12 (SD 5) and 11 (SD 3) mmHg, respectively. New pacemaker implantation was necessary in 8.6% of patients. A single case (0.2%) of structural degeneration was registered after 6 years. Valve explantation for non-structural dysfunction or endocarditis occurred in 9 patients (1.8%). CONCLUSIONS This rapid deployment aortic valve has shown excellent results concerning haemodynamic performance, durability and safety. Implantation requires specific training, and the rate of pacemaker implantation remains a matter of concern. This novel valve also facilitates minimally invasive approaches and may be beneficial in complex combined procedures.
引用
收藏
页码:527 / 533
页数:7
相关论文
共 50 条
[21]   Rapid-deployment aortic valve replacement for patients with bicuspid aortic valve: a single-centre experience [J].
Coti, Iuliana ;
Werner, Paul ;
Kaider, Alexandra ;
Mach, Markus ;
Kocher, Alfred ;
Laufer, Guenther ;
Andreas, Martin .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2022, 62 (04)
[22]   Anterior Right Thoracotomy for Rapid-Deployment Aortic Valve Replacement [J].
Wiedemann, Dominik ;
Laufer, Guenther ;
Coti, Iuliana ;
Mahr, Stephane ;
Scherzer, Sabine ;
Haberl, Thomas ;
Kocher, Alfred ;
Andreas, Martin .
ANNALS OF THORACIC SURGERY, 2021, 112 (02) :564-571
[23]   Early-Term Results of Rapid-Deployment Aortic Valve Replacement versus Standard Bioprosthesis Implantation Combined with Coronary Artery Bypass Grafting [J].
Taghiyev, Zulfugar T. ;
Bechtel, Matthias ;
Schloemicher, Markus ;
Useini, Dritan ;
Taghi, Hamid Naraghi ;
Moustafine, Vadim ;
Strauch, Justus T. .
THORACIC AND CARDIOVASCULAR SURGEON, 2023, 71 (07) :519-527
[24]   Rapid-Deployment Aortic Valve Replacement in a Real-World All-Comers Population [J].
Yun, Taeyoung ;
Kim, Kyung Hwan ;
Sohn, Suk Ho ;
Kang, Yoonjin ;
Kim, Ji Seong ;
Choi, Jae Woong .
THORACIC AND CARDIOVASCULAR SURGEON, 2023, 71 (07) :511-518
[25]   Rapid-deployment aortic valve replacement versus standard bioprosthesis implantation [J].
Ferrari, Enrico ;
Roduit, Christelle ;
Salamin, Pauline ;
Caporali, Elena ;
Demertzis, Stefanos ;
Tozzi, Piergiorgio ;
Berdajs, Denis ;
von Segesser, Ludwig .
JOURNAL OF CARDIAC SURGERY, 2017, 32 (06) :322-327
[26]   Long-term outcomes of a rapid deployment aortic valve: data up to 5 years [J].
Laufer, Guenther ;
Haverich, Axel ;
Andreas, Martin ;
Mohr, Friedrich W. ;
Walther, Thomas ;
Shrestha, Malakh ;
Rahmanian, Parwis ;
Holzhey, David ;
Roth, Matthias ;
Schmitz, Christoph ;
Schramm, Rene ;
Giot, Christophe ;
Wahlers, Thorsten C. W. .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2017, 52 (02) :281-287
[27]   New postoperative conduction abnormalities after the implantation of a rapid-deployment aortic valve prosthesis [J].
Mogilansky, Christian ;
Balan, Robert ;
Deutsch, Cornelia ;
Czesla, Markus ;
Massoudy, Parwis .
INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY, 2019, 28 (04) :581-586
[28]   The role of sutureless or rapid-deployment aortic valve prosthesis in bicuspid aortic valve: Standard AVR, TAVR, or somewhere in between? [J].
Ohira, Suguru ;
De la Pena, Corazon .
JOURNAL OF CARDIAC SURGERY, 2022, 37 (10) :3363-3364
[29]   Percutaneous Treatment of Paravalvular Leak in Rapid-Deployment Bioprosthetic Aortic Valve With Balloon Dilation [J].
Pivato, Carlo Andrea ;
Regazzoli, Damiano ;
Rossi, Alexia ;
Pagliaro, Beniamino .
CARDIOVASCULAR REVASCULARIZATION MEDICINE, 2020, 21 (11) :S47-S49
[30]   Outcome of rapid deployment aortic valves: long-term experience after 700 implants [J].
Coti, Iuliana ;
Haberl, Thomas ;
Scherzer, Sabine ;
Werner, Paul ;
Shabanian, Shiva ;
Kocher, Alfred ;
Laufer, Guenther ;
Andreas, Martin .
ANNALS OF CARDIOTHORACIC SURGERY, 2020, 9 (04) :314-321