Calculated depth dose distributions for proton beams in some low-Z materials

被引:29
|
作者
Palmans, H
Verhaegen, F
机构
[1] Department of Biomedical Physics, University of Gent, B-9000 Gent
来源
PHYSICS IN MEDICINE AND BIOLOGY | 1997年 / 42卷 / 06期
关键词
D O I
10.1088/0031-9155/42/6/013
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The extended use of proton beams in clinical radiotherapy has increased the need to investigate the accuracy of dosimetry for this type of beam. As for photon and electron beams, Monte Carlo simulations are a useful tool in the study of proton dosimetry. The existing proton Monte Carlo code PTRAN developed for dosimetry purposes is designed for transport of protons in homogeneous water only. In clinical proton dosimetry as well as in treatment conditions several other materials can be present, such as plastic phantoms, plastic modulator wheels and several materials in ionization chambers. To investigate the transport of protons in other media we started from the PTRAN code, and implemented proton transport in other materials including heterogeneous systems composed of different materials. With this extended code, calculations of depth dose distributions for some low-Z materials are performed and compared with those obtained for water. The results show that for plastics (PMMA, polystyrene and A150) the depth dose characteristics are comparable to those of water. For graphite, air and aluminium larger differences are observed. The differences between water and the low-Z materials studied here are small but can be important for accurate dosimetry.
引用
收藏
页码:1175 / 1183
页数:9
相关论文
共 50 条
  • [1] Solar proton dose exposures using low-Z and high-Z materials
    Atwell, Bill
    Bartholet, Bill
    Reddell, Brandon
    Townsend, Lawrence W.
    Miller, Thomas
    Edwards, John
    Campbell, Christina
    2005 IEEE Aerospace Conference, Vols 1-4, 2005, : 712 - 717
  • [2] PROTON STOPPING POWERS IN SOME LOW-Z ELEMENTS
    SHARADA, KS
    RADIATION RESEARCH, 1993, 136 (03) : 335 - 340
  • [3] SPUTTERING OF LOW-Z MATERIALS
    ROTH, J
    ECKSTEIN, W
    GAUTHIER, E
    LASZLO, J
    JOURNAL OF NUCLEAR MATERIALS, 1991, 179 : 34 - 36
  • [4] An analytical approximation of depth-dose distributions for therapeutic proton beams
    Bortfeld, T
    Schlegel, W
    PHYSICS IN MEDICINE AND BIOLOGY, 1996, 41 (08): : 1331 - 1339
  • [5] The scattering of muons in low-Z materials
    Attwood, D.
    Bell, P.
    Bull, S.
    McMahon, T.
    Wilson, J.
    Fernow, R.
    Gruber, P.
    Jamdagm, A.
    Long, K.
    McKigney, E.
    Savage, P.
    Curtis-Rouse, M.
    Edgecock, T. R.
    Ellis, M.
    Lidbury, J.
    Murray, W.
    Norton, P.
    Peach, K.
    Ishida, K.
    Matsuda, Y.
    Nagamine, K.
    Nakamura, S.
    Marshall, G. M.
    Benveniste, S.
    Cline, D.
    Fukui, Y.
    Lee, K.
    Pischalnikov, Y.
    Holmes, S.
    Bogacz, A.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2006, 251 (01): : 41 - 55
  • [6] PHYSICAL SPUTTERING OF LOW-Z MATERIALS
    GAUTHIER, E
    ECKSTEIN, W
    LASZLO, J
    ROTH, J
    JOURNAL OF NUCLEAR MATERIALS, 1990, 176 : 438 - 444
  • [7] CALCULATED DEPTH DOSE DISTRIBUTIONS IN AN ANTHROPOMORPHIC PHANTOM
    SCHERPELZ, RI
    TANNER, JE
    BRACKENBUSH, LW
    HEALTH PHYSICS, 1987, 52 : S68 - S69
  • [8] Calculated depth-dose distributions for H+ and He+ beams in liquid water
    Garcia-Molina, Rafael
    Abril, Isabel
    Denton, Cristian D.
    Heredia-Avalos, Santiago
    Kyriakou, Ioanna
    Emfietzoglou, Dimitris
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2009, 267 (16): : 2647 - 2652
  • [9] Verification of some low-Z silicates as gamma-ray shielding materials
    Mann, Kulwinder Singh
    Sidhu, Gurdeep S.
    ANNALS OF NUCLEAR ENERGY, 2012, 40 (01) : 241 - 252
  • [10] INTERACTION STUDIES AND GAMMA-RAY PROPERTIES OF SOME LOW-Z MATERIALS
    Bhosale, Rameshwar R.
    Gaikwad, Dhammajyot K.
    Pawar, Pravina P.
    Rode, Madhav N.
    NUCLEAR TECHNOLOGY & RADIATION PROTECTION, 2016, 31 (02): : 135 - 141