Reliability and fatigue failure modes of implant-supported aluminum-oxide fixed dental prostheses

被引:4
|
作者
Stappert, Christian F. J. [1 ,2 ]
Baldassarri, Marta [1 ]
Zhang, Yu
Haenssler, Felix [1 ]
Rekow, Elizabeth D.
Thompson, Van P.
机构
[1] NYU, Coll Dent, Dept Biomat & Biomimet, Dept Periodontol & Implant Dent, New York, NY 10010 USA
[2] Univ Freiburg, Dept Prosthodont, D-79106 Freiburg, Germany
基金
美国国家科学基金会;
关键词
aluminum-oxide; bridge; ceramic; chewing simulation; chipping; fatigue; fixed-partial-denture; fracture; veneering porcelain; Weibull-reliability; FRACTURE-TOUGHNESS; TOOTH REPLACEMENT; FLEXURAL STRENGTH; CERAMICS; ABUTMENTS; ZIRCONIA; FORCE;
D O I
10.1111/j.1600-0501.2011.02281.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives To investigate failure modes and reliability of implant-supported aluminum-oxide three-unit fixed dental prostheses (FDPs) using two different veneering porcelains. Material and methods Thirty-six aluminum-oxide FDP frameworks were computer-aided designed and computer-aided manufactured and either hand-veneered(n = 18) or over-pressed(n = 18). All FDPs were adhesively luted to custom-made zirconium-oxide-abutments attached to dental implant fixtures (regular platform 4 x 13 mm). Specimens were stored in water before mechanical testing. A step-stress accelerated life test (SSALT) with three load/cycles varying profiles was developed based on initial single-load-to-failure testing. Failure was defined by veneer chipping or chipping in combination with framework fracture. SSALT was performed on each FDP inclined 30 degrees with respect to the applied load direction. For all specimens, failure modes were analyzed using polarized reflected light microscopy and scanning electron microscopy. Reliability was computed using Weibull analysis software (Reliasoft). Results The dominant failure mode for the over-pressed FDPs was buccal chipping of the porcelain in the loading area of the pontic, while hand-veneered specimens failed mainly by combined failure modes in the veneering porcelain, framework, and abutments. Chipping of the porcelain occurred earlier in the over-pressed specimens (350 N/85 k, load/cycles) than in the hand-veneered ones (600 N/110 k) (profile I). Given a mission at 300 N load and 100 or 200 k cycles, the computed Weibull reliability (two-sided at 90% confidence bounds) was 0.99(1/0.98) and 0.99(1/0.98) for hand-veneered FDPs and 0.45(0.76/0.10) and 0.05(0.63/0) for over-pressed FDPs, respectively. Conclusions In the range of average clinical loads (300700 N), hand-veneered aluminum-oxide FDPs showed significantly less failure by chipping of the veneer than the over-pressed. Hand-veneered FDPs under fatigue loading failed at loads =600 N.
引用
收藏
页码:1173 / 1180
页数:8
相关论文
共 50 条
  • [1] Reliability and failure modes of implant-supported zirconium-oxide fixed dental prostheses related to veneering techniques
    Baldassarri, Marta
    Zhang, Yu
    Thompson, Van P.
    Rekow, Elizabeth D.
    Stappert, Christian F. J.
    JOURNAL OF DENTISTRY, 2011, 39 (07) : 489 - 498
  • [2] Static and Fatigue Loading of Veneered Implant-Supported Fixed Dental Prostheses
    Rayyan, Mohammad M.
    Abdallah, Jihad
    Segaan, Lucette G.
    Bonfante, Estevam A.
    Osman, Essam
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2020, 29 (08): : 679 - 685
  • [3] Digital Impressions for Implant-Supported Fixed Dental Prostheses
    Lee S.J.
    Lee J.D.
    Current Oral Health Reports, 2017, 4 (2) : 136 - 141
  • [4] Retention of titanium copings to implant-supported fixed dental prostheses
    Chiam, Sieu Yien
    Lee, Hsin Lin
    Bedrossian, Armand E.
    Xu, Qianhui
    Kuykendall, William
    Ren, Anna
    Hess, Timothy A.
    Ramos Jr, Van
    Chung, Kwok-Hung
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2024, 33 (04): : 340 - 347
  • [5] Fracture analysis of randomized implant-supported fixed dental prostheses
    Esquivel-Upshaw, Josephine F.
    Mehler, Alex
    Clark, Arthur E.
    Neal, Dan
    Anusavice, Kenneth J.
    JOURNAL OF DENTISTRY, 2014, 42 (10) : 1335 - 1342
  • [6] Fracture behavior of all-ceramic, implant-supported, and tooth–implant-supported fixed dental prostheses
    Abdul Rahman Alkharrat
    Marc Schmitter
    Stefan Rues
    Peter Rammelsberg
    Clinical Oral Investigations, 2018, 22 : 1663 - 1673
  • [7] Technical complications with implant-supported dental prostheses
    Calderon, Patricia S.
    Dantas, Poliana M. C.
    Montenegro, Sheyla C. L.
    Carreiro, Adriana F. P.
    Oliveira, Angelo G. R. C.
    Dantas, Euler M.
    Gurgel, Bruno C. V.
    JOURNAL OF ORAL SCIENCE, 2014, 56 (02) : 179 - 184
  • [8] The Use of Zirconia for Implant-Supported Fixed Complete Dental Prostheses: A Narrative Review
    Cinquini, Chiara
    Alfonsi, Fortunato
    Marchio, Vincenzo
    Gallo, Francesco
    Zingari, Francesco
    Bolzoni, Alessandro Remigio
    Romeggio, Stefano
    Barone, Antonio
    DENTISTRY JOURNAL, 2023, 11 (06)
  • [9] Oral rehabilitation with implant-supported fixed dental prostheses of a patient with cleidocranial dysplasia
    Atil, Fethi
    Culhaoglu, Ahmet
    Kocyigit, Ismail Doruk
    Adisen, Zahit
    Misirlioglu, Melda
    Yilmaz, Burak
    JOURNAL OF PROSTHETIC DENTISTRY, 2018, 119 (01): : 12 - 16
  • [10] Implant-Supported Fixed Dental Prostheses in an Edentulous Patient with Dystrophic Epidermolysis Bullosa
    Mueller, Frauke