Low sensitivity of the echocardiograph compared with contrast transcranial doppler in right-to-left shunt

被引:15
作者
Martinez-Sanchez, P. [1 ]
Medina-Baez, J.
Lara-Lara, M.
Oliva-Navarro, J.
Cazorla-Garcia, R.
Ruiz-Ares, G.
Martinez-Martinez, M.
Fuentes, B.
Diez-Tejedor, E.
机构
[1] Univ Autonoma Madrid, Inst Invest IdiPAZ, Hosp Univ La Paz, Lab Explorac Neurovasc Ultrasonograf Serv Neurol, Madrid, Spain
来源
NEUROLOGIA | 2012年 / 27卷 / 02期
关键词
Transcranial Doppler; Echocardiography; Right-to-left shunt; Patent foramen ovale; Cerebral ischaemia; Accuracy; PATENT FORAMEN OVALE; INTERATRIAL SEPTAL ABNORMALITIES; TRANSESOPHAGEAL ECHOCARDIOGRAPHY; STROKE PATIENTS; TRANSTHORACIC ECHOCARDIOGRAPHY; CRYPTOGENIC STROKE; ULTRASOUND; SONOGRAPHY; MIGRAINE;
D O I
10.1016/j.nrl.2011.05.010
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Background: Contrast transcranial Doppler (c-TCD) has a high sensitivity for detecting right-to-left shunt (RLS), and is probably higher than transthoracic echocardiography (TTE) and comparable with transesophageal echocardiography (TEE). Objective: To evaluate the accuracy of echocardiography (TIE and TEE) to detect RLS compared to c-TCD. Material and methods: Observational study of patients <55 years old with cerebral ischaemia of undetermined origin (2007-2009). All underwent c-TCD monitoring to detect RLS, at rest and after Valsalva manoeuvre (VM). The TTE and TEE were performed when indicated by our cerebrovascular protocol. The accuracy of TTE and TEE for detecting RLS was calculated by comparing them with c-TCD. Results: A total of 115 patients with c-TCD, mean age 43.3 (SD 10.3) years, 51.3% male. The TTE was performed in 102, and TEE in 81, patients. RLS detection was higher with c-TCD than with TIE (67.6% vs. 22.5%, P=.001) or TEE (77.8% vs. 53.1%, P=.001). The TIE, compared with c-TCD after MV showed: sensitivity 31.8%, specificity 96.9%, positive predictive value (PPV) 95.6%, negative predictive value (NPV) 40.5% and accuracy 52.9% to detect RLS. TEE, compared with c-TCD after MV showed: sensitivity 63.4%, specificity 83.3%, PPV 93%, NPV 39.4% and accuracy 67.9%. The accuracy of TIE and TEE improved when they were compared with c-TCD at rest. Conclusions: TIE and TEE show a considerable number of false negatives for RLS detection. Clinical studies should consider the c-TCD as the best technique to diagnose RLS when a paradoxical embolism is suspected. (C) 2011 Sociedad Espanola de Neurologia. Published by Elsevier Espana, S.L. All rights reserved.
引用
收藏
页码:61 / 67
页数:7
相关论文
共 22 条
  • [1] Arboix A, 1998, Neurologia, V13 Suppl 3, P3
  • [2] Transcranial Doppler and Transesophageal Echocardiography: Comparison of Both Techniques and Prospective Clinical Relevance of Transcranial Doppler in Patent Foramen Ovale Detection
    Caputi, Luigi
    Carriero, Maria Rita
    Falcone, Chiara
    Parati, Eugenio
    Piotti, Patrizia
    Materazzo, Carlo
    Anzola, Gian Paolo
    [J]. JOURNAL OF STROKE & CEREBROVASCULAR DISEASES, 2009, 18 (05) : 343 - 348
  • [3] TRANSCRANIAL DOPPLER ULTRASOUND IDENTIFIES PATIENTS WITH RIGHT-TO-LEFT CARDIAC OR PULMONARY SHUNTS
    CHIMOWITZ, MI
    NEMEC, JJ
    MARWICK, TH
    LORIG, RJ
    FURLAN, AJ
    SALCEDO, EE
    [J]. NEUROLOGY, 1991, 41 (12) : 1902 - 1904
  • [4] Controlled contrast transcranial Doppler and arterial blood gas analysis to quantify shunt through patent foramen ovale
    Devuyst, G
    Piechowski-Józwiak, B
    Karapanayiotides, T
    Fitting, JW
    Kémeny, V
    Hirt, L
    Urbano, LA
    Arnold, P
    van Melle, G
    Despland, PA
    Bogousslavsky, J
    [J]. STROKE, 2004, 35 (04) : 859 - 863
  • [5] COMPARISON OF DIAGNOSTIC-TECHNIQUES FOR THE DETECTION OF A PATENT FORAMEN OVALE IN STROKE PATIENTS
    DITULLIO, M
    SACCO, RL
    VENKETASUBRAMANIAN, N
    SHERMAN, D
    MOHR, JP
    HOMMA, S
    [J]. STROKE, 1993, 24 (07) : 1020 - 1024
  • [6] Contrast transcranial Doppler ultrasound in the detection of right-to-left shunts -: Time window and threshold in microbubble numbers
    Droste, DW
    Silling, K
    Stypmann, J
    Grude, M
    Kemény, V
    Wichter, T
    Kühne, K
    Ringelstein, EB
    [J]. STROKE, 2000, 31 (07) : 1640 - 1645
  • [7] Detection of right-to-left shunt with ultrasound contrast agent and transcranial Doppler sonography
    Jauss, M
    Zanette, E
    [J]. CEREBROVASCULAR DISEASES, 2000, 10 (06) : 490 - 496
  • [8] COMPARISON OF TRANSCRANIAL CONTRAST DOPPLER SONOGRAPHY AND TRANSESOPHAGEAL CONTRAST ECHOCARDIOGRAPHY FOR THE DETECTION OF PATENT FORAMEN OVALE IN YOUNG STROKE PATIENTS
    JOB, FP
    RINGELSTEIN, EB
    GRAFEN, Y
    FLACHSKAMPF, FA
    DOHERTY, C
    STOCKMANNS, A
    HANRATH, P
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1994, 74 (04) : 381 - 384
  • [9] Patent foramen ovale: A review of associated conditions and the impact of physiological size
    Kerut, EK
    Norfleet, WT
    Plotnick, GD
    Giles, TD
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2001, 38 (03) : 613 - 623
  • [10] Kimura K, 1999, AM J NEURORADIOL, V20, P1881