Reproducibility Measurement of Glutathione, GABA, and Glutamate: Towards In Vivo Neurochemical Profiling of Multiple Sclerosis With MR Spectroscopy at 7T

被引:72
作者
Prinsen, Hetty [1 ]
de Graaf, Robin A. [1 ,2 ]
Mason, Graeme F. [1 ,3 ]
Pelletier, Daniel [4 ]
Juchem, Christoph [1 ,4 ]
机构
[1] Yale Univ, Dept Radiol & Biomed Imaging, New Haven, CT USA
[2] Yale Univ, Dept Biomed Engn, New Haven, CT USA
[3] Yale Univ, Dept Psychiat, New Haven, CT 06520 USA
[4] Yale Univ, Dept Neurol, New Haven, CT USA
基金
美国国家卫生研究院;
关键词
MAGNETIC-RESONANCE-SPECTROSCOPY; HUMAN VISUAL-CORTEX; HUMAN-BRAIN INVIVO; H-1-NMR SPECTROSCOPY; METABOLITE CONCENTRATIONS; OXIDATIVE STRESS; T-2; RELAXATION; H-1-MRS; SPECTRA; TESLA;
D O I
10.1002/jmri.25356
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To determine the reproducibility of a comprehensive single-session measurement of glutathione (GSH), gamma-aminobutyric acid (GABA), glutamate, and other biochemicals implicated in the pathophysiology of multiple sclerosis (MS) in the human brain with H-1 magnetic resonance spectroscopy (MRS). Materials and Methods: Five healthy subjects were studied twice in separate 1-hour sessions at 7T. One MS patient was also scanned once. GSH and GABA were measured with J-difference editing using a semilocalized by adiabatic selective refocusing sequence (semi-LASER, TE=72 msec). A stimulated echo acquisition mode sequence (STEAM, TE=10 msec) was used to detect glutamate along with the overall biochemical profile. Spectra were quantified with LCModel. Quantification accuracy was assessed through Cramer-Rao lower bounds (CRLB). Reproducibility of the metabolite quantification was tested using coefficients of variation (CoV). Results: CRLB were <= 7% for GSH, GABA, and glutamate and average CoV of 7.8 +/- 3.2%, 9.5 +/- 7.0%, and 3.2 +/- 1.7% were achieved, respectively. The average test/retest concentration differences at this measurement reproducibility and quantification accuracy were smaller for GABA and glutamate than intersubject variations in metabolite content with CoV ratios of 0.6 and 0.8, respectively. As proof of principle, GSH, GABA, and glutamate were also detected in an MS patient. Conclusion: GSH, GABA, glutamate, and other metabolites relevant in MS can be quantified at 7T with high accuracy and reproducibility in a single 1-hour session. This methodology might serve as a clinical research tool to investigate biochemical markers associated with MS.
引用
收藏
页码:187 / 198
页数:12
相关论文
共 62 条
  • [1] Efficient spectral editing at 7 T: GABA detection with MEGA-sLASER
    Andreychenko, Anna
    Boer, Vincent O.
    de Castro, Catalina S. Arteaga
    Luijten, Peter R.
    Klomp, Dennis W. J.
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2012, 68 (04) : 1018 - 1025
  • [2] PROTON MAGNETIC-RESONANCE SPECTROSCOPY OF HUMAN BRAIN INVIVO IN THE EVALUATION OF MULTIPLE-SCLEROSIS - ASSESSMENT OF THE LOAD OF DISEASE
    ARNOLD, DL
    MATTHEWS, PM
    FRANCIS, G
    ANTEL, J
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1990, 14 (01) : 154 - 159
  • [3] Genetic variation influences glutamate concentrations in brains of patients with multiple sclerosis
    Baranzini, Sergio E.
    Srinivasan, Radhika
    Khankhanian, Pouya
    Okuda, Darin T.
    Nelson, Sarah J.
    Matthews, Paul M.
    Hauser, Stephen L.
    Oksenberg, Jorge R.
    Pelletier, Daniel
    [J]. BRAIN, 2010, 133 : 2603 - 2611
  • [4] Neurochemical and BOLD responses during neuronal activation measured in the human visual cortex at 7 Tesla
    Bednarik, Petr
    Tkac, Ivan
    Giove, Federico
    DiNuzzo, Mauro
    Deelchand, Dinesh K.
    Emir, Uzay E.
    Eberly, Lynn E.
    Mangia, Silvia
    [J]. JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 2015, 35 (04) : 601 - 610
  • [5] ANALYSIS OF MACROMOLECULE RESONANCES IN H-1-NMR SPECTRA OF HUMAN BRAIN
    BEHAR, KL
    ROTHMAN, DL
    SPENCER, DD
    PETROFF, OAC
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1994, 32 (03) : 294 - 302
  • [6] Inhibitory role for GABA in autoimmune inflammation
    Bhat, Roopa
    Axtell, Robert
    Mitra, Ananya
    Miranda, Melissa
    Lock, Christopher
    Tsien, Richard W.
    Steinman, Lawrence
    [J]. PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2010, 107 (06) : 2580 - 2585
  • [7] Bottomley PA, 1984, US Patent, Patent No. [4 1984:480/228, 41984480228]
  • [8] CALABRESE V, 1994, INT J CLIN PHARM RES, V14, P119
  • [9] Cramer-Rao bound expressions for parametric estimation of overlapping peaks: Influence of prior knowledge
    Cavassila, S
    Deval, S
    Huegen, C
    van Ormondt, D
    Graveron-Demilly, D
    [J]. JOURNAL OF MAGNETIC RESONANCE, 2000, 143 (02) : 311 - 320
  • [10] Doubly selective multiple quantum chemical shift imaging and T1 relaxation time measurement of glutathione (GSH) in the human brain in vivo
    Choi, In-Young
    Lee, Phil
    [J]. NMR IN BIOMEDICINE, 2013, 26 (01) : 28 - 34