This paper represents the second part of a major work focusing on a trigeneration system integrating a low temperature polymer electrolyte fuel cell (PEMFC) and a desiccant wheel-based air handling unit. Low temperature PEMFC systems have a significant potential in combined heating, cooling and power applications. However cogenerated heat temperature is relatively low (up to 65-70 degrees C), resulting in low efficiency of the cooling process, and the fuel processor is far from being flexible, hindering the operation of the system at low load conditions. Therefore a trigeneration system based on PEMFC should be carefully designed through accurate simulation tools. In the current paper a detailed analysis of the energy performance of the trigenerative system is provided, taking into account constraints of real applications, such as PEMFC part load behavior, desiccant wheel effectiveness, heat storage losses and air handling unit electrical consumptions. The methodology adopted to model system components is deeply described. Energy simulations are performed on yearly basis with variable building air conditioning loads and climate conditions, in order to investigate the optimal trigenerative unit size. A sensitivity analysis on crucial design parameters is provided. It is shown that constrains of actual applications have relevant effects on system energy consumption, which is significantly far from expected values based on a simplified analysis. Primary energy savings can be positive in winter time if the ratio of PEMFC heating capacity to air conditioning peak heating load is close to 0.15. Instead on yearly basis primary energy savings cannot be achieved with present components performance. Positive savings can be potentially achieved if PEMFC system and auxiliary devices are properly improved. (C) 2015 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1460 / 1470
页数:11
相关论文
共 50 条
  • [31] Exergy-energy, economic and environmental evaluation of a solid oxide fuel cell based trigeneration system using double effect vapor absorption refrigeration system
    Khan, Yunis
    Singh, Pawan Kumar
    Anjum, Aftab
    Sivakumar, K. K.
    Gupta, Shikha
    Mishra, Subhash
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2025, 174 : 343 - 358
  • [32] Catalytic layers in a reversible system comprising an electrolyzing cell and a fuel cell based on solid polymer electrolyte
    M. A. Tsypkin
    E. K. Lyutikova
    V. N. Fateev
    V. D. Rusanov
    Russian Journal of Electrochemistry, 2000, 36 : 545 - 548
  • [33] Performance analysis of an industrial waste heat-based trigeneration system
    Khaliq, A.
    Kumar, R.
    Dincer, I.
    INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2009, 33 (08) : 737 - 744
  • [34] Energy and exergy analyses of an ethanol-fueled solid oxide fuel cell for a trigeneration system
    Tippawan, Phanicha
    Arpornwichanop, Amornchai
    Dincer, Ibrahim
    ENERGY, 2015, 87 : 228 - 239
  • [35] Development of an energy management system for optimal operation of fuel cell based residential energy systems
    Aki, Hirohisa
    Wakui, Tetsuya
    Yokoyama, Ryohei
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2016, 41 (44) : 20314 - 20325
  • [36] System Design and Energy Management for a Fuel Cell/Battery Hybrid Forklift
    You, Zhiyu
    Wang, Liwei
    Han, Ying
    Zare, Firuz
    ENERGIES, 2018, 11 (12)
  • [37] A multi-objective optimisation model for a general polymer electrolyte membrane fuel cell system
    Ang, Sheila Mae C.
    Brett, Daniel J. L.
    Fraga, Eric S.
    JOURNAL OF POWER SOURCES, 2010, 195 (09) : 2754 - 2763
  • [38] Accumulation of Inert Impurities in a Polymer Electrolyte Fuel Cell System with Anode Recirculation and Periodic Purge: A Simple Analytical Model
    Gardner, Christopher L.
    Sarma, Paran J.
    Kjeang, Erik
    ENERGIES, 2022, 15 (06)
  • [39] Performance analysis of a solar based novel trigeneration system using cascaded vapor absorption-compression refrigeration system
    Khan, Yunis
    Mishra, R. S.
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2023, 155 : 207 - 218
  • [40] A Simplified Fuel Cell Model for System Analysis and Performance Simulation
    Zhao, Ziliang
    Du, Jing
    Zhao, Honghui
    Xu, Dechao
    Qu, Lucheng
    Wang, Yupeng
    IECON 2020: THE 46TH ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY, 2020, : 4994 - 4999