A trigeneration system based on polymer electrolyte fuel cell and desiccant wheel - Part B: Overall system design and energy performance analysis

被引:8
|
作者
Intini, M. [1 ]
De Antonellis, S. [1 ]
Joppolo, C. M. [1 ]
Casalegno, A. [1 ]
机构
[1] Politecn Milan, Dept Energy, I-20156 Milan, Italy
关键词
Trigeneration; PEMFC; Fuel cell; Desiccant wheel; Primary energy saving; TRI-GENERATION SYSTEM; MICRO-TRIGENERATION; OPTIMIZATION; TECHNOLOGY; STRATEGIES; OPERATION;
D O I
10.1016/j.enconman.2015.10.005
中图分类号
O414.1 [热力学];
学科分类号
摘要
This paper represents the second part of a major work focusing on a trigeneration system integrating a low temperature polymer electrolyte fuel cell (PEMFC) and a desiccant wheel-based air handling unit. Low temperature PEMFC systems have a significant potential in combined heating, cooling and power applications. However cogenerated heat temperature is relatively low (up to 65-70 degrees C), resulting in low efficiency of the cooling process, and the fuel processor is far from being flexible, hindering the operation of the system at low load conditions. Therefore a trigeneration system based on PEMFC should be carefully designed through accurate simulation tools. In the current paper a detailed analysis of the energy performance of the trigenerative system is provided, taking into account constraints of real applications, such as PEMFC part load behavior, desiccant wheel effectiveness, heat storage losses and air handling unit electrical consumptions. The methodology adopted to model system components is deeply described. Energy simulations are performed on yearly basis with variable building air conditioning loads and climate conditions, in order to investigate the optimal trigenerative unit size. A sensitivity analysis on crucial design parameters is provided. It is shown that constrains of actual applications have relevant effects on system energy consumption, which is significantly far from expected values based on a simplified analysis. Primary energy savings can be positive in winter time if the ratio of PEMFC heating capacity to air conditioning peak heating load is close to 0.15. Instead on yearly basis primary energy savings cannot be achieved with present components performance. Positive savings can be potentially achieved if PEMFC system and auxiliary devices are properly improved. (C) 2015 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1460 / 1470
页数:11
相关论文
共 50 条
  • [1] A tri-generation system based on polymer electrolyte fuel cell and desiccant wheel - Part A: Fuel cell system modelling and partial load analysis
    Najafi, Behzad
    De Antonellis, Stefano
    Intini, Manuel
    Zago, Matteo
    Rinaldi, Fabio
    Casalegno, Andrea
    ENERGY CONVERSION AND MANAGEMENT, 2015, 106 : 1450 - 1459
  • [2] Optimization, Economic, Energy and Exergy Analyses of a Trigeneration System with Solid Oxide Fuel Cell Prime Mover and Desiccant Refrigeration System
    Zahmatkesh, Ali
    Mehregan, Mahmood
    IRANIAN JOURNAL OF SCIENCE AND TECHNOLOGY-TRANSACTIONS OF MECHANICAL ENGINEERING, 2024, : 549 - 569
  • [3] 1 Polymer electrolyte fuel cell system (PEFC) performance analysis
    Tirnovan, R.
    Miraoui, A.
    Munteanu, R.
    Vadan, I.
    Balan, H.
    2006 IEEE-TTTC INTERNATIONAL CONFERENCE ON AUTOMATION, QUALITY AND TESTING, ROBOTICS, VOL 1, PROCEEDINGS, 2006, : 457 - +
  • [4] Solid Oxide Fuel Cell Trigeneration System and Performance Analysis
    Wang S.
    Lu X.
    Mei S.
    Zhu Y.
    Tianjin Daxue Xuebao (Ziran Kexue yu Gongcheng Jishu Ban)/Journal of Tianjin University Science and Technology, 2021, 54 (10): : 1061 - 1069
  • [5] Thermodynamic performance analysis of a fuel cell trigeneration system integrated with solar-assisted methanol reforming
    Wang, Jiangjiang
    Wu, Jing
    Xu, Zilong
    Li, Meng
    ENERGY CONVERSION AND MANAGEMENT, 2017, 150 : 81 - 89
  • [6] Design Models of Polymer Electrolyte Membrane Fuel Cell System
    Mulyazmi
    Daud, Wan Ramli Wan
    Majlan, Edy Herianto
    ADVANCED PRECISION ENGINEERING, 2010, 447-448 : 554 - 558
  • [7] Exergy Performance Analysis and Optimization of a Desiccant Wheel System
    Mandegari, Mohsen Ali
    Farzad, Somayeh
    Pahlavanzadeh, Hassan
    JOURNAL OF THERMAL SCIENCE AND ENGINEERING APPLICATIONS, 2015, 7 (03)
  • [8] Energy and exergy assessments of a novel trigeneration system based on a solid oxide fuel cell
    Ranjbar, Faramarz
    Chitsaz, Ata
    Mahmoudi, S. M. S.
    Khalilarya, Shahram
    Rosen, Marc A.
    ENERGY CONVERSION AND MANAGEMENT, 2014, 87 : 318 - 327
  • [9] Decoupling pressure and distribution effects of flow fields on polymer electrolyte fuel cell system performance
    Heck, Joshua D.
    Vaz, Warren S.
    Koylu, Umit O.
    Leu, Ming C.
    SUSTAINABLE ENERGY TECHNOLOGIES AND ASSESSMENTS, 2019, 36
  • [10] The Effect of Thermal Management on the Performance of a Polymer Electrolyte Membrane Fuel Cell System
    Lee, Jeong Ho
    Myung, No Sung
    Kim, Tong Seop
    TRANSACTIONS OF THE KOREAN SOCIETY OF MECHANICAL ENGINEERS B, 2011, 35 (06) : 593 - 601