Calcium score of small coronary calcifications on multidetector computed tomography: Results from a static phantom study

被引:17
作者
Groen, J. M. [1 ]
Kofoed, K. F. [2 ]
Zacho, M. [2 ]
Vliegenthart, R. [1 ]
Willems, T. P. [1 ]
Greuter, M. J. W. [1 ]
机构
[1] Univ Groningen, Univ Med Ctr Groningen, Dept Radiol, NL-9700 RB Groningen, Netherlands
[2] Univ Groningen, Rigshosp, Dept Cardiol & Radiol, NL-9700 RB Groningen, Netherlands
关键词
Computed tomography; Coronary calcium; Calcium score; ELECTRON-BEAM CT; ARTERY CALCIUM; AMERICAN-COLLEGE; DUAL SOURCE; DISEASE; REPRODUCIBILITY; QUANTIFICATION; MDCT; ANGIOGRAPHY; GUIDELINES;
D O I
10.1016/j.ejrad.2012.09.018
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Introduction: Multi detector computed tomography (MDCT) underestimates the coronary calcium score as compared to electron beam tomography (EBT). Therefore clinical risk stratification based on MDCT calcium scoring may be inaccurate. The aim of this study was to assess the feasibility of a new phantom which enables establishment of a calcium scoring protocol for MDCT that yields a calcium score comparable to the EBT values and to the physical mass. Materials and methods: A phantom containing 100 small calcifications ranging from 0.5 to 2.0 mm was scanned on EBT using a standard coronary calcium protocol. In addition, the phantom was scanned on a 320-row MDCT scanner using different scanning, reconstruction and scoring parameters (tube voltage 80-135 kV, slice thickness 0.5-3.0 mm, reconstruction kernel FC11-FC15 and threshold 110-150 HU). The Agatston and mass score of both modalities was compared and the influence of the parameters was assessed. Results: On EBT the Agatston and mass scores were between 0 and 20, and 0 and 3 mg, respectively. On MDCT the Agatston and mass scores were between 0 and 20, and 0 and 4 mg, respectively. All parameters showed an influence on the calcium score. The Agatston score on MDCT differed 52% between the 80 and 135 kV, 65% between 0.5 and 3.0 mm and 48% between FC11 and FC15. More calcifications were detected with a lower tube voltage, a smaller slice thickness, a sharper kernel and a lower threshold. Based on these observations an acquisition protocol with a tube voltage of 100 kV and two reconstructions protocols were defined with a FC12 reconstruction kernel; one with a slice thickness of 3.0 mm and a one with a slice thickness of 0.5 mm. This protocol yielded an Agatston score as close to the EBT as possible, but also a mass score as close to the physical phantom value as possible, respectively. Conclusion: With the new phantom one acquisition protocol and two reconstruction protocols can be defined which produces Agatston scores comparable to EBT values and to the physical mass. (c) 2012 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:E58 / E63
页数:6
相关论文
共 33 条
[1]   QUANTIFICATION OF CORONARY-ARTERY CALCIUM USING ULTRAFAST COMPUTED-TOMOGRAPHY [J].
AGATSTON, AS ;
JANOWITZ, WR ;
HILDNER, FJ ;
ZUSMER, NR ;
VIAMONTE, M ;
DETRANO, R .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1990, 15 (04) :827-832
[2]   Prediction of coronary events with electron beam computed tomography [J].
Arad, Y ;
Spadaro, LA ;
Goodman, K ;
Newstein, D ;
Guerci, AD .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2000, 36 (04) :1253-1260
[3]   Peak SNR in automated coronary calcium scoring: Selecting CT scan parameters and statistically defined scoring thresholds [J].
Arnold, Ben A. ;
Xiang, Ping ;
Mao, Song S. ;
Budoff, Matthew J. .
MEDICAL PHYSICS, 2010, 37 (07) :3621-3632
[4]   Coronary artery calcium measurement: Agreement of multirow detector and electron beam CP [J].
Becker, CR ;
Kleffel, T ;
Crispin, A ;
Knez, A ;
Young, J ;
Schoepf, UJ ;
Haberl, R ;
Reiser, MF .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2001, 176 (05) :1295-1298
[5]   Reproducibility of Coronary Artery Calcified Plaque with Cardiac 64-MDCT: The Multi-Ethnic Study of Atherosclerosis [J].
Budoff, Matthew Jay ;
McClelland, Robyn L. ;
Chung, Hyoju ;
Wong, Nathan D. ;
Carr, J. Jeffrey ;
Gray, Michael McNitt ;
Blumenthal, Roger S. ;
Detrano, Robert C. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2009, 192 (03) :613-617
[6]   Ultrafast computed tomography as a diagnostic modality in the detection of coronary artery disease: A multicenter study [J].
Budoff, MJ ;
Georgiou, D ;
Brody, A ;
Agatston, AS ;
Kennedy, J ;
Wolfkiel, C ;
Stanford, W ;
Shields, P ;
Lewis, RJ ;
Janowitz, WR ;
Rich, S ;
Brundage, BH .
CIRCULATION, 1996, 93 (05) :898-904
[7]   Coronary artery disease: Improved reproducibility of calcium scoring with an electron-beam CT volumetric method [J].
Callister, TQ ;
Cooil, B ;
Raya, SP ;
Lippolis, NJ ;
Russo, DJ ;
Raggi, P .
RADIOLOGY, 1998, 208 (03) :807-814
[8]   Frequency and risk factors associated with atherosclerotic plaques in patients with a zero coronary artery calcium score [J].
Chen, Chun-Ku ;
Kuo, Yen-Shu ;
Liu, Chien-An ;
Sheu, Ming-Huei ;
Chang, Hsiao-Ting ;
Chen, Chi-Wen ;
Chen, Yu-Dong ;
Wu, Mei-Han ;
Chang, Cheng-Yen .
JOURNAL OF THE CHINESE MEDICAL ASSOCIATION, 2012, 75 (01) :10-15
[9]   Concordance of coronary artery calcium estimates between MDCT and electron beam tomography [J].
Daniell, AL ;
Wong, ND ;
Friedman, JD ;
Ben-Yosef, N ;
Miranda-Peats, R ;
Hayes, SW ;
Kang, XP ;
Sciammarella, MG ;
de Yang, L ;
Germano, G ;
Berman, DS .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2005, 185 (06) :1542-1545
[10]  
Detrano R, 1995, Am J Card Imaging, V9, P167