Biomechanical and rheological characterization of mild intervertebral disc degeneration in a large animal model

被引:29
作者
Detiger, Suzanne E. L. [1 ,2 ,3 ]
Hoogendoorn, Roel J. W. [1 ]
van der Veen, Albert J. [2 ,3 ,4 ]
van Royen, Barend J. [1 ,2 ,3 ]
Helder, Marco N. [1 ,2 ,3 ]
Koenderink, Gijsje H. [5 ]
Smit, Theo H. [1 ,2 ,3 ]
机构
[1] Vrije Univ Amsterdam Med Ctr, Dept Orthopaed Surg, Amsterdam, Netherlands
[2] STEGA, Amsterdam, Netherlands
[3] Res Inst MOVE, Amsterdam, Netherlands
[4] Vrije Univ Amsterdam Med Ctr, Dept Phys & Med Technol, Amsterdam, Netherlands
[5] FOM Inst AMOLF, Amsterdam, Netherlands
关键词
nucleus pulposus; biomechanics; viscoelasticity; animal model; disc degeneration; PULPOSUS GLYCOSAMINOGLYCAN CONTENT; LUMBAR NUCLEUS PULPOSUS; CELL-SHAPE; MECHANICS; BEHAVIOR; BIOLOGY;
D O I
10.1002/jor.22296
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Biomechanical properties of healthy and degenerated nucleus pulposus (NP) are thought to be important for future regenerative strategies for intervertebral disc (IVD) repair. However, which properties are pivotal as design criteria when developing NP replacement materials is ill understood. Therefore, we determined and compared segmental biomechanics and NP viscoelastic properties in normal and mildly degenerated discs. In eight goats, three lumbar IVDs were chemically degenerated using chondroitinase ABC (CABC), confirmed with radiography and MRI after euthanasia 12 weeks post-operative. Neutral zone (NZ) stiffness and range of motion (ROM) were determined sagitally, laterally, and rotationally for each spinal motion segment (SMS) using a mechanical testing device. NPs were isolated for oscillatory shear experiments; elastic and viscous shear moduli followed from the ratio between shear stress and strain. Water content was quantified by weighing before and after freeze-drying. Disc height on radiographs and signal intensity on MRI decreased (6% and 22%, respectively, p<0.01) after CABC treatment, confirming that chemical degeneration provides a good model of disc degeneration. Furthermore, CABC-injected IVDs had significantly lower NZ stiffness and larger ROM in lateral bending (LB) and axial rotation (AR) than controls. Rheometry consistently revealed significantly lower (1012%) viscoelastic moduli after mild degeneration within goats, though the inter-animal differences were relatively large (complex modulus approximate to 12 to 41kPa). Relative water content in the NP was unaffected by CABC, remaining at approximate to 75%. These observations suggest that viscoelastic properties have a marginal influence on mechanical behavior of the whole SMS. Therefore, when developing replacement materials the focus should be on other design criteria, such as biochemical cues and swelling pressure. (c) 2012 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 31: 703709, 2013
引用
收藏
页码:703 / 709
页数:7
相关论文
共 38 条
[1]   What is intervertebral disc degeneration, and what causes it? [J].
Adams, Michael A. ;
Roughley, Peter J. .
SPINE, 2006, 31 (18) :2151-2161
[2]  
Anderson D Greg, 2005, Spine J, V5, p297S, DOI 10.1016/j.spinee.2005.02.019
[3]   An in vivo model of reduced nucleus pulposus glycosaminoglycan content in the rat lumbar intervertebral disc [J].
Boxberger, John I. ;
Auerbach, Joshua D. ;
Sen, Sounok ;
Elliott, Dawn M. .
SPINE, 2008, 33 (02) :146-154
[4]   Nucleus pulposus glycosaminoglycan content is correlated with axial mechanics in rat lumbar motion segments [J].
Boxberger, John I. ;
Sen, Sounok ;
Yerramalli, Chandra S. ;
Elliott, Dawn M. .
JOURNAL OF ORTHOPAEDIC RESEARCH, 2006, 24 (09) :1906-1915
[5]   Rheological Characterization of the Nucleus Pulposus and Dense Collagen Scaffolds Intended for Functional Replacement [J].
Bron, J. L. ;
Koenderink, G. H. ;
Everts, V. ;
Smit, T. H. .
JOURNAL OF ORTHOPAEDIC RESEARCH, 2009, 27 (05) :620-626
[6]   Engineering alginate for intervertebral disc repair [J].
Bron, Johannes L. ;
Vonk, Lucienne A. ;
Smit, Theodoor H. ;
Koenderink, Gijsje H. .
JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2011, 4 (07) :1196-1205
[7]   Measurement of cadaver lumbar spine motion segment stiffness [J].
Brown, MD ;
Holmes, DC ;
Heiner, AD .
SPINE, 2002, 27 (09) :918-922
[8]  
Calderon L, 2010, EUR CELLS MATER, V20, P134
[9]   Structure and Biology of the Intervertebral Disk in Health and Disease [J].
Chan, Wilson C. W. ;
Sze, Kit Ling ;
Samartzis, Dino ;
Leung, Victor Y. L. ;
Chan, Danny .
ORTHOPEDIC CLINICS OF NORTH AMERICA, 2011, 42 (04) :447-+
[10]   Prevalence and Pattern of Lumbar Magnetic Resonance Imaging Changes in a Population Study of One Thousand Forty-Three Individuals [J].
Cheung, Kenneth M. C. ;
Karppinen, Jaro ;
Chan, Danny ;
Ho, Daniel W. H. ;
Song, You-Qiang ;
Sham, Pak ;
Cheah, Kathryn S. E. ;
Leong, John C. Y. ;
Luk, Keith D. K. .
SPINE, 2009, 34 (09) :934-940