Diagnostic accuracy of multislice computed tomography coronary angiography is improved at low heart rates

被引:47
作者
Cademartiri, F
Mollet, NR
Runza, G
Belgrano, M
Malagutti, P
Meijboom, BW
Midiri, M
de Feyter, PJ
Krestin, GP
机构
[1] Erasmus Univ, Med Ctr, Dept Radiol, NL-3015 GD Rotterdam, Netherlands
[2] Erasmus Univ, Med Ctr, Dept Cardiol, NL-3015 GD Rotterdam, Netherlands
[3] Univ Palermo, Dept Radiol, I-90133 Palermo, Italy
关键词
coronary angiography; diagnostic accuracy; heart rate; 16-row multislice CT; technical development;
D O I
10.1007/s10554-005-9010-6
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Purpose: Assess the effect of heart rate on diagnostic accuracy for the detection of significant coronary artery stenosis using 16-row multislice computed tomography (MSCT). Material and methods: About 120 patients (105 males; 59 +/- 11 years) with suspected coronary artery disease who underwent conventional coronary angiography (CA) and MSCT-CA were retrospectively enrolled for the study. Patients underwent a MSCT-CA (Sensation 16, Siemens, Germany), with the following protocol: collimation 16x0.75 mm, gantry rotation time 420 ms, feed/rotation 3.0 mm, kV 120, mAs 400-500. The protocol for contrast material administration was 100 ml of Iodixanol (Visipaque 320 mg l/ml, Amersham, UK) at 4 ml/s and the delay was defined with a bolus tracking technique. In all patients the mean heart rate (HR) during the scan was used as a criteria to divide the population in two groups of 60 patients each. In one group (Low HR) the 60 patients with lower heart rates, and in the other group (High HR) the patients with higher heart rates. In the two groups diagnostic accuracy (per coronary segment) for the detection of significant stenosis (>= 50% lumen reduction) was evaluated in vessels >= 2 mm of diameter using quantitative CA as reference standard. The difference in diagnostic accuracy were compared with a Chi(2) test and a p < 0.05 was considered significant. Results: There was no significant difference between the two groups regarding age, gender, weight, mean intravascular attenuation, and calcium score. Overall 1310 (652 for Low HR and 658 for High HR) segments with 219 (105 for Low HR and 114 for High HR) significant lesions were available for the analysis. The average heart rate was 52 +/- 4HU and 63 +/- 5HU for Low HR and High HR, respectively (p < 0.001). The sensitivity and specificity were 92 and 96% for Low HR and 90 and 92% for High HR (p < 0.05). There were 22 vs. 44 false positives, and 8 vs. 12 false negatives in the Low HR and High HR, respectively. Conclusion: Increasing HR significantly deteriorates diagnostic accuracy in MSCT-CA.
引用
收藏
页码:101 / 105
页数:5
相关论文
共 7 条
[1]  
Austen W G, 1975, Circulation, V51, P5
[2]   Predictive value of 16-slice multidetector spiral computed tomography to detect significant obstructive coronary artery disease in patients at high risk for coronary artery disease - Patient-versus segment-based analysis [J].
Hoffmann, U ;
Moselewski, F ;
Cury, RC ;
Ferencik, M ;
Jang, IK ;
Diaz, LJ ;
Abbara, S ;
Brady, TJ ;
Achenbach, S .
CIRCULATION, 2004, 110 (17) :2638-2643
[3]   Multislice spiral computed tomography coronary angiography in patients with stable angina pectoris [J].
Mollet, NR ;
Cademartiri, F ;
Nieman, K ;
Saia, F ;
Lemos, PA ;
McFadden, EP ;
Pattynama, PMT ;
Serruys, PW ;
Krestin, GP ;
de Feyter, PJ .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2004, 43 (12) :2265-2270
[4]   Reliable noninvasive coronary angiography with fast submillimeter multislice spiral computed tomography [J].
Nieman, K ;
Cademartiri, F ;
Lemos, PA ;
Raaijmakers, R ;
Pattynama, PMT ;
de Feyter, PJ .
CIRCULATION, 2002, 106 (16) :2051-2054
[5]   Non-invasive coronary angiography with multislice spiral computed tomography: impact of heart rate [J].
Nieman, K ;
Rensing, BJ ;
van Geuns, RJM ;
Vos, J ;
Pattynama, PMT ;
Krestin, GP ;
Serruys, PW ;
de Feyter, PJ .
HEART, 2002, 88 (05) :470-474
[6]   Detection of coronary artery stenoses with thin-slice multi-detector row spiral computed tomography and multiplanar reconstruction [J].
Ropers, D ;
Baum, U ;
Pohle, K ;
Anders, K ;
Ulzheimer, S ;
Ohnesorge, B ;
Schlundt, C ;
Bautz, W ;
Daniel, WG ;
Achenbach, S .
CIRCULATION, 2003, 107 (05) :664-666
[7]   Influence of heart rate on vessel visibility in noninvasive coronary angiography using new multislice computed tomography - Experience in 94 patients [J].
Schroeder, S ;
Kopp, AF ;
Kuettner, A ;
Burgstahler, C ;
Herdeg, C ;
Heuschmid, M ;
Baumbach, A ;
Claussen, CD ;
Karsch, KR ;
Seipel, L .
CLINICAL IMAGING, 2002, 26 (02) :106-111