Chemometric-assisted method development in reversed-phase liquid chromatography

被引:51
作者
Cela, R. [1 ]
Ordonez, E. Y. [1 ]
Quintana, J. B. [1 ]
Rodil, R. [1 ]
机构
[1] Univ Santiago de Compostela, Dept Analyt Chem & Food Sci, Inst Res Food Anal, Santiago De Compostela, Spain
关键词
Chromatographic optimization; Computerized separations; Chemometrics in chromatography; ARTIFICIAL NEURAL-NETWORKS; OFF-LINE OPTIMIZATION; RESTRICTED MULTIPARAMETER APPROACH; MULTILINEAR GRADIENT ELUTION; MASS SPECTROMETRY; COLUMN SELECTIVITY; MOBILE-PHASE; BACKGROUND REDUCTION; PROGRAMMED ELUTIONS; COMPONENT DETECTION;
D O I
10.1016/j.chroma.2012.07.081
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The computer-assisted development of separation procedures in liquid chromatography (LC), which has involved the adaptation of diverse chemometric techniques and the incorporation of successive advances in informatics and computing over a period of more than four decades, has provided chromatographers with commercial and academic tools of great utility. These tools enable the development, optimization (including robustness studies) and transfer of procedures that constitute one of the analytical activities most commonly used at present in laboratories and industries worldwide. Departing from a typical operational scheme of manually developed chromatographic procedures, this review describes some of the different tools and options that chemometrics provides to the chromatographer for the computer-assisted approach, and outlines the present status of this approach and possible reasons why it is still not considered fully satisfactory. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:2 / 22
页数:21
相关论文
共 112 条
[31]  
Euerby M.R., 2000, LC GC EUR, V13, P665
[32]   Chromatographic classification and comparison of commercially available reversed-phase liquid chromatographic columns containing phenyl moieties using principal component analysis [J].
Euerby, Melvin R. ;
Petersson, Patrik ;
Campbell, William ;
Roe, Wendy .
JOURNAL OF CHROMATOGRAPHY A, 2007, 1154 (1-2) :138-151
[33]   Windowed mass selection method: a new data processing algorithm for liquid chromatography-mass spectrometry data [J].
Fleming, CM ;
Kowalski, BR ;
Apffel, A ;
Hancock, WS .
JOURNAL OF CHROMATOGRAPHY A, 1999, 849 (01) :71-85
[34]   Modeling retention and selectivity as a function of pH and column temperature in liquid chromatography [J].
Gagliardi, Leonardo G. ;
Castells, Cecilia B. ;
Rafols, Clara ;
Roses, Marti ;
Bosch, Elisabeth .
ANALYTICAL CHEMISTRY, 2006, 78 (16) :5858-5867
[35]   Computer-assisted method development in liquid chromatography-mass spectrometry: New proposals [J].
Garcia-Lavandeira, J. ;
Losada, B. ;
Martinez-Pontevedra, J. A. ;
Lores, M. ;
Cela, R. .
JOURNAL OF CHROMATOGRAPHY A, 2008, 1208 (1-2) :116-125
[36]   Computer-assisted transfer of programmed elutions in reversed-phase high-performance liquid chromatography [J].
Garcia-Lavandeira, J. ;
Martinez-Pontevedra, J. A. ;
Lores, M. ;
Cela, R. .
JOURNAL OF CHROMATOGRAPHY A, 2006, 1128 (1-2) :17-26
[37]   Computer-assisted modelling and optimisation of reversed-phase high-temperature liquid chromatographic (RP-HTLC) separations [J].
Garcia-Lavandeira, J. ;
Oliveri, P. ;
Martinez-Pontevedra, J. A. ;
Bollain, M. H. ;
Forina, M. ;
Cela, R. .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2011, 399 (06) :1951-1964
[38]   Simultaneous reversed-phase high-performance liquid chromatographic separation of mono-, di-and trichloroanilines through a gradient elution optimised by experimental design [J].
Gennaro, MC ;
Marengo, E ;
Gianotti, V ;
Angioi, S .
JOURNAL OF CHROMATOGRAPHY A, 2002, 945 (1-2) :287-292
[39]  
Glajch J.L., 1983, J CHROMATOGR, V255, P21
[40]   Improved baseline recognition and modeling of FT NMR spectra [J].
Golotvin, S ;
Williams, A .
JOURNAL OF MAGNETIC RESONANCE, 2000, 146 (01) :122-125