Determination of pulp vitality in vivo with pulse oximetry

被引:36
|
作者
Calil, E. [1 ]
Caldeira, C. L. [2 ,3 ]
Gavini, G. [2 ,3 ]
Lemos, E. M. [1 ]
机构
[1] Univ Guarulhos, Sch Dent, Dept Endodont, Sao Paulo, Brazil
[2] Univ Sao Paulo, Sch Dent, Dept Endodont, Sao Paulo, Brazil
[3] Univ Santa Cecilia, Sch Dent, Sao Paulo, Brazil
关键词
pulse oximetry; dental pulp test; endodontics;
D O I
10.1111/j.1365-2591.2008.01421.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Aim To evaluate the use of pulse oximetry as a test for pulp vitality, by comparing in the same patient, the levels of oxygen saturation of the index finger and of the maxillary central incisor and canine teeth without clinically detectable pulp inflammation. Methodology Seventeen male and female patients aged between 26 and 38 years participated and a total of 32 maxillary central incisor and 32 canine teeth were analysed. Selection criteria required the teeth to have healthy crowns, or with restorations no more than 2 mm in diameter and no clinical and radiographical signs or symptoms of pulp or periapical inflammatory changes. The negative control group consisted of 10 root filled teeth. Measurements were first taken from the index finger of patients. Their teeth were then subjected to a thermal test with refrigerant gas and then to a vitality test with pulse oximetry. Data were analysed by Pearson's and paired t-tests. Results There were no significant statistical correlations between blood oxygen levels in the index finger and in the teeth of the patient (P > 0.05). There was a statistically significant difference in the oxygen levels between the two tooth groups studied and the index finger (P <= 0.002). Mean oxygen values in the index finger of patients were 95% (SD = 1.6), oxygen values in the maxillary central incisor were 91.29% (SD = 2.61) and mean oxygen values in maxillary canine were 90.69% (SD = 2.71). Conclusion The method determined consistently the level of blood oxygen saturation of the pulp in maxillary central incisor and canine teeth and can therefore be used for pulp vitality testing. Further studies are required to assess the effectiveness and validity of pulse oximetry in determining pulp vitality in traumatized teeth.
引用
收藏
页码:741 / 746
页数:6
相关论文
共 50 条
  • [21] Pulse oximetry in the oesophagus
    Kyriacou, PA
    PHYSIOLOGICAL MEASUREMENT, 2006, 27 (01) : R1 - R35
  • [22] Pulse oximetry in pediatrics
    Carbajal, R
    ARCHIVES DE PEDIATRIE, 1996, 3 (11): : 1129 - 1135
  • [23] Six months follow-up with pulse oximetry and electric pulp test of teeth with trauma
    Kosturkov, D.
    Uzunov, Ts.
    20TH INTERNATIONAL CONFERENCE AND SCHOOL ON QUANTUM ELECTRONICS: LASER PHYSICS AND APPLICATIONS, 2019, 11047
  • [24] Pulp Vitality Diagnosis by Means of an Optical Pulp Scanning Device
    Marroquin, Benjamin Briseno
    Borgschulte, Markus
    Savic, Alexander
    Ertl, Thomas Peter
    Wolf, Thomas Gerhard
    DENTISTRY JOURNAL, 2024, 12 (10)
  • [25] Determination of Relaxed and Hypoventilation Body Conditions Using Pulse Oximetry and Temperature Measurements
    Billones, Robert Kerwin C.
    Belen, Miguel Guerrero Z.
    Lee, Brent Joseph P.
    Salud, Nathan T.
    Sergio, Roxanne C.
    Tamayo, Gayle R.
    Vicerra, Ryan Rhay P.
    Dadios, Elmer P.
    2020 IEEE 12TH INTERNATIONAL CONFERENCE ON HUMANOID, NANOTECHNOLOGY, INFORMATION TECHNOLOGY, COMMUNICATION AND CONTROL, ENVIRONMENT, AND MANAGEMENT (HNICEM), 2020,
  • [26] Intraoperative determination of intestinal viability: A comparison with transserosal pulse oximetry and histopathological examination
    Erikoglu, M
    Kaynak, A
    Beyath, EA
    Toy, H
    JOURNAL OF SURGICAL RESEARCH, 2005, 128 (01) : 66 - 69
  • [27] Comment on “Pulse oximetry” by Jubran
    Aikaterini Maliaga
    Stavroula Boulia
    Charalampos Martinos
    Ilias Andrianakis
    Intensive Care Medicine, 2007, 33 : 740 - 740
  • [28] DEVELOPMENT SYSTEM FOR PULSE OXIMETRY
    LEUTHNER, T
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1994, 32 (05) : 596 - 598
  • [29] DIFFUSION-BASED MODEL OF PULSE OXIMETRY - IN-VITRO AND IN-VIVO COMPARISONS
    MARBLE, DR
    BURNS, DH
    CHEUNG, PW
    APPLIED OPTICS, 1994, 33 (07): : 1279 - 1285
  • [30] TENSION PNEUMOTHORAX AND PULSE OXIMETRY
    LAISHLEY, RS
    APS, C
    BRITISH JOURNAL OF ANAESTHESIA, 1991, 66 (02) : 250 - 252