Electrocardiogram Provides a Continuous Heart Rate Faster Than Oximetry During Neonatal Resuscitation

被引:106
作者
Katheria, Anup [1 ]
Rich, Wade [1 ]
Finer, Neil [1 ]
机构
[1] Univ Calif San Diego, Div Neonatol, UCSD Med Ctr, San Diego, CA 92103 USA
关键词
ECG; heart rate; pulse oximetry; resuscitation; very low birth weight; PULSE OXIMETRY; DELIVERY ROOM; ACCURACY; INFANTS;
D O I
10.1542/peds.2012-0784
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
OBJECTIVE: To compare the time required to obtain a continuous audible heart rate signal from an electrocardiogram (ECG) monitor and pulse oximeter (PO) in infants requiring resuscitation. METHODS: Infants who had both ECG and PO placed during resuscitation were analyzed using video and analog recordings. The median times from arrival until the ECG electrodes and PO sensor were placed, and the time to achieve audible tones from the devices, were compared. RESULTS: Forty-six infants had ECG and PO data. Thirty infants were very low birth weight (23-30 weeks). There was a difference in the median total time to place either device (26 vs 38 seconds; P = .04), and a difference (P < .001) in the time to achieve an audible heart rate signal after ECG lead (2 seconds) versus PO probe (24 seconds) placement. In infants weighing >1500 g (n = 16), the median time (interquartile range) to place the ECG was 20 seconds (14-43) whereas the time to place the PO was 36 seconds (28-56) (P = .74). The median times (interquartile range) to acquire a signal from the ECG and PO were 4 seconds (1-6) and 32 seconds (15-40, P = .001), respectively. During the first minutes of resuscitation, 93% of infants had an ECG heart rate compared with only 56% for PO. CONCLUSIONS: Early application of ECG electrodes during infant resuscitation can provide the resuscitation team with a continuous audible heart rate, and its use may improve the timeliness of appropriate critical interventions. Pediatrics 2012;130:e1177-e1181
引用
收藏
页码:E1177 / E1181
页数:5
相关论文
共 50 条
  • [21] Characterisation of Heart Rate Changes and their Correlation with EEG During Neonatal Seizures
    Doyle, O. M.
    Greene, B. R.
    Marnane, W.
    Lightbody, G.
    Boylan, G. B.
    2008 30TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-8, 2008, : 4984 - +
  • [22] A capaciflector provides continuous and accurate respiratory rate monitoring for patients at rest and during exercise
    Hayward, Nick
    Shaban, Mahdi
    Badger, James
    Jones, Isobel
    Wei, Yang
    Spencer, Daniel
    Isichei, Stefania
    Knight, Martin
    Otto, James
    Rayat, Gurinder
    Levett, Denny
    Grocott, Michael
    Akerman, Harry
    White, Neil
    JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2022, 36 (05) : 1535 - 1546
  • [23] The effect of maternal oxygen administration on fetal pulse oximetry during labor in fetuses with nonreassuring fetal heart rate patterns
    Haydon, Michael L.
    Gorenberg, David M.
    Nageotte, Michael P.
    Ghamsary, Mark
    Rumney, Pamela I.
    Patillo, Carol
    Garite, Thomas J.
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2006, 195 (03) : 735 - 738
  • [24] Agreement between Electrocardiogram and Heart Rate Meter Is Low for the Measurement of Heart Rate Variability during Exercise in Young Endurance Horses
    Lenoir, Augustin
    Trachsel, Dagmar S.
    Younes, Mohamed
    Barrey, Eric
    Robert, Celine
    FRONTIERS IN VETERINARY SCIENCE, 2017, 4
  • [25] The accuracy of human senses in the detection of neonatal heart rate during standardized simulated resuscitation: Implications for delivery of care, training and technology design
    Chitkara, Ritu
    Rajani, Anand K.
    Oehlert, John W.
    Lee, Henry C.
    Epi, M. S.
    Halamek, Louis P.
    RESUSCITATION, 2013, 84 (03) : 369 - 372
  • [26] Heart rate variability and electrocardiogram waveform as predictors of morbidity during hypothermia and rewarming in rats
    Matthew, CB
    Bastille, AM
    Gonzalez, RR
    Sils, IV
    CANADIAN JOURNAL OF PHYSIOLOGY AND PHARMACOLOGY, 2002, 80 (09) : 925 - 933
  • [27] Continuous recording of heart rate during specific exercises of judo
    Houvenaeghel, M
    Bizzari, C
    Giallurachis, D
    Demelas, JM
    SCIENCE & SPORTS, 2005, 20 (01) : 27 - 32
  • [28] Variable Height Step Test Provides Reliable Heart Rate Values During Virtual Cardiorespiratory Fitness Testing
    Matthews, Evan L.
    Horvat, Fiona M.
    Phillips, David A.
    MEASUREMENT IN PHYSICAL EDUCATION AND EXERCISE SCIENCE, 2022, 26 (02) : 155 - 164
  • [29] Electrocardiographic dynamic development and heart rate variability in lambs during the neonatal period
    Chiacchio, Simone Biagio
    Vela Ulian, Carla Maria
    Goncalves, Renato de Souza
    Padovani, Carlos Roberto
    Salgueiro Cruz, Raissa Karolliny
    Santarosa, Bianca Paola
    Alfonso, Angelica
    Gomes Lourenco, Maria Lucia
    JOURNAL OF APPLIED ANIMAL RESEARCH, 2018, 46 (01) : 1137 - 1143
  • [30] Fetal heart rate variability during pregnancy, obtained from non-invasive electrocardiogram recordings
    Van Laar, Judith O. E. H.
    Warmerdam, Guy J. J.
    Verdurmen, Kim M. J.
    Vullings, Rik
    Peters, Chris H. L.
    Houterman, Saskia
    Wijn, Pieter F. F.
    Andriessen, Peter
    Van Pul, Carola
    Oei, S. Guid
    ACTA OBSTETRICIA ET GYNECOLOGICA SCANDINAVICA, 2014, 93 (01) : 93 - 101