Electrocardiogram Provides a Continuous Heart Rate Faster Than Oximetry During Neonatal Resuscitation

被引:110
作者
Katheria, Anup [1 ]
Rich, Wade [1 ]
Finer, Neil [1 ]
机构
[1] Univ Calif San Diego, Div Neonatol, UCSD Med Ctr, San Diego, CA 92103 USA
关键词
ECG; heart rate; pulse oximetry; resuscitation; very low birth weight; PULSE OXIMETRY; DELIVERY ROOM; ACCURACY; INFANTS;
D O I
10.1542/peds.2012-0784
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
OBJECTIVE: To compare the time required to obtain a continuous audible heart rate signal from an electrocardiogram (ECG) monitor and pulse oximeter (PO) in infants requiring resuscitation. METHODS: Infants who had both ECG and PO placed during resuscitation were analyzed using video and analog recordings. The median times from arrival until the ECG electrodes and PO sensor were placed, and the time to achieve audible tones from the devices, were compared. RESULTS: Forty-six infants had ECG and PO data. Thirty infants were very low birth weight (23-30 weeks). There was a difference in the median total time to place either device (26 vs 38 seconds; P = .04), and a difference (P < .001) in the time to achieve an audible heart rate signal after ECG lead (2 seconds) versus PO probe (24 seconds) placement. In infants weighing >1500 g (n = 16), the median time (interquartile range) to place the ECG was 20 seconds (14-43) whereas the time to place the PO was 36 seconds (28-56) (P = .74). The median times (interquartile range) to acquire a signal from the ECG and PO were 4 seconds (1-6) and 32 seconds (15-40, P = .001), respectively. During the first minutes of resuscitation, 93% of infants had an ECG heart rate compared with only 56% for PO. CONCLUSIONS: Early application of ECG electrodes during infant resuscitation can provide the resuscitation team with a continuous audible heart rate, and its use may improve the timeliness of appropriate critical interventions. Pediatrics 2012;130:e1177-e1181
引用
收藏
页码:E1177 / E1181
页数:5
相关论文
共 9 条
[1]   Accuracy of pulse oximetry measurement of heart rate of newborn infants in the delivery room [J].
Kamlin, C. Omar F. ;
Dawson, Jennifer A. ;
O'Donnell, Colm P. F. ;
Morley, Colin J. ;
Donath, Susan M. ;
Sekhon, Jasbir ;
Davis, Peter G. .
JOURNAL OF PEDIATRICS, 2008, 152 (06) :756-760
[2]   Accuracy of clinical assessment of infant heart rate in the delivery room [J].
Kamlin, C. Omar F. ;
O'Donnell, Colm P. F. ;
Everest, Neil J. ;
Davis, Peter G. ;
Morley, Colin J. .
RESUSCITATION, 2006, 71 (03) :319-321
[3]  
Kattwinkel J., 2010, Text Book of Neonatal Resuscitation, V6th
[4]  
Kattwinkel J., 2000, Textbook of Neonatal Resuscitation: American Academy of Pediatrics
[5]   Electrocardiogram shows reliable heart rates much earlier than pulse oximetry during neonatal resuscitation [J].
Mizumoto, Hiroshi ;
Tomotaki, Seiichi ;
Shibata, Hirofumi ;
Ueda, Kazutoshi ;
Akashi, Ryoko ;
Uchio, Hiroko ;
Hata, Daisuke .
PEDIATRICS INTERNATIONAL, 2012, 54 (02) :205-207
[6]   Feasibility of and delay in obtaining pulse oximetry during neonatal resuscitation [J].
O'Donnell, CPF ;
Kamlin, COF ;
Davis, PG ;
Morley, CJ .
JOURNAL OF PEDIATRICS, 2005, 147 (05) :698-699
[7]   Delivery Room Intervention: Improving the Outcome [J].
Rich, Wade D. ;
Leone, Tina ;
Finer, Neil N. .
CLINICS IN PERINATOLOGY, 2010, 37 (01) :189-+
[8]   Premedication for nonemergent neonatal intubations: A randomized, controlled trial comparing atropine and fentanyl to atropine, fentanyl, and mivacurium [J].
Roberts, Kari D. ;
Leone, Tina A. ;
Edwards, William H. ;
Rich, Wade D. ;
Finer, Neil N. .
PEDIATRICS, 2006, 118 (04) :1583-1591
[9]   Accuracy of pulse oximetry in assessing heart rate of infants in the neonatal intensive care unit [J].
Singh, Jasbir K. S. B. ;
Kamlin, C. Omar F. ;
Morley, Colin J. ;
O'Donnell, Colm P. F. ;
Donath, Susan M. ;
Davis, Peter G. .
JOURNAL OF PAEDIATRICS AND CHILD HEALTH, 2008, 44 (05) :273-275