Setup Variations in Radiotherapy of Anal Cancer: Advantages of Target Volume Reduction Using Image-Guided Radiation Treatment

被引:20
作者
Chen, Yi-Jen [1 ]
Suh, Steve [1 ]
Nelson, Rebecca A. [2 ]
Liu, An [1 ]
Pezner, Richard D. [1 ]
Wong, Jeffrey Y. C. [1 ]
机构
[1] City Hope Natl Med Ctr, Div Radiat Oncol, Duarte, CA 91010 USA
[2] City Hope Natl Med Ctr, Div Informat Sci, Duarte, CA 91010 USA
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 2012年 / 84卷 / 01期
关键词
Image-guided radiation therapy; Setup variation; Radiotherapy; Anal cancer; CONCURRENT CHEMOTHERAPY; CONFORMAL RADIOTHERAPY; CARCINOMA; THERAPY; UNCERTAINTIES; FLUOROURACIL; MITOMYCIN; COVERAGE; GUIDANCE; POSITION;
D O I
10.1016/j.ijrobp.2011.10.068
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To define setup variations in the radiation treatment (RT) of anal cancer and to report the advantages of image-guided RT (IGRT) in terms of reduction of target volume and treatment-related side effects. Methods and Materials: Twelve consecutive patients with anal cancer treated by combined chemoradiation by use of helical tomotherapy from March 2007 to November 2008 were selected. With patients immobilized and positioned in place, megavoltage computed tomography (MVCT) scans were performed before each treatment and were automatically registered to planning CT scans. Patients were shifted per the registration data and treated. A total of 365 MVCT scans were analyzed. The primary site received a median dose of 55 Gy. To evaluate the potential dosimetric advantage(s) of IGRT, cases were replanned according to Radiation Therapy Oncology Group 0529, with and without adding recommended setup variations from the current study. Results: Significant setup variations were observed throughout the course of RT. The standard deviations for systematic setup correction in the anterior-posterior (AP), lateral, and superior-inferior (SI) directions and roll rotation were 1.1, 3.6, and 3.2 mm, and 0.3 degrees, respectively. The average random setup variations were 3.8, 5.5, and 2.9 mm, and 0.5 degrees, respectively. Without daily IGRT, margins of 4.9, 11.1, and 8.5 mm in the AP, lateral, and SI directions would have been needed to ensure that the planning target volume (PTV) received >= 95% of the prescribed dose. Conversely, daily IGRT required no extra margins on PTV and resulted in a significant reduction of V15 and V45 of intestine and V10 of pelvic bone marrow. Favorable toxicities were observed, except for acute hematologic toxicity. Conclusions: Daily MVCT scans before each treatment can effectively detect setup variations and thereby reduce PTV margins in the treatment of anal cancer. The use of concurrent chemotherapy and IGRT provided favorable toxicities, except for acute hematologic toxicity. (C) 2012 Elsevier Inc.
引用
收藏
页码:289 / 295
页数:7
相关论文
共 33 条
[1]   Fluorouracil, mitomycin, and radiotherapy vs fluorouracil, cisplatin, and radiotherapy for carcinoma of the anal canal - A randomized controlled trial [J].
Ajani, Jaffer A. ;
Winter, Kathryn A. ;
Gunderson, Leonard L. ;
Pedersen, John ;
Benson, Al B., III ;
Thomas, Charles R., Jr. ;
Mayer, Robert J. ;
Haddock, Michael G. ;
Rich, Tyvin A. ;
Willett, Christopher .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2008, 299 (16) :1914-1921
[2]   Portal imaging for evaluation of daily on-line setup errors and off-line organ motion during conformal irradiation of carcinoma of the prostate [J].
Alasti, H ;
Petric, MP ;
Catton, CN ;
Warde, PR .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2001, 49 (03) :869-884
[3]  
[Anonymous], 50 ICRU MEAS
[4]  
[Anonymous], ANN M GASTR CANC S J
[5]  
Arnott SJ, 1996, LANCET, V348, P1049
[6]   Concomitant radiotherapy and chemotherapy is superior to radiotherapy alone in the treatment of locally advanced anal cancer: Results of a phase III randomized trial of the European organization for research and treatment of cancer radiotherapy and gastrointestinal cooperative groups [J].
Bartelink, H ;
Roelofsen, F ;
Eschwege, F ;
Rougier, P ;
Bosset, JF ;
Gonzalez, DG ;
Peiffert, D ;
vanGlabbeke, M ;
Pierart, M .
JOURNAL OF CLINICAL ONCOLOGY, 1997, 15 (05) :2040-2049
[7]   MAXIMIZING SETUP ACCURACY USING PORTAL IMAGES AS APPLIED TO A CONFORMAL BOOST TECHNIQUE FOR PROSTATIC-CANCER [J].
BIJHOLD, J ;
LEBESQUE, JV ;
HART, AAM ;
VIJLBRIEF, RE .
RADIOTHERAPY AND ONCOLOGY, 1992, 24 (04) :261-271
[8]   Setup variations in radiotherapy of esophageal cancer: Evaluation by daily megavoltage computed tomographic localization [J].
Chen, Yi-Jen ;
Han, Chunhui ;
Liu, An ;
Schultheiss, Timothy E. ;
Kernstine, Kemp H. ;
Shibata, Stephen ;
Vora, Nayana L. ;
Pezner, Richard D. ;
Wong, Jeffrey Y. C. .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 68 (05) :1537-1545
[9]   Organ sparing by conformal avoidance intensity-modulated radiation therapy for anal cancer: Dosimetric evaluation of coverage of pelvis and inguinal/femoral nodes [J].
Chen, YJ ;
Liu, A ;
Tsai, PT ;
Vora, NL ;
Pezner, RD ;
Schultheiss, TE ;
Wong, JYC .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 63 (01) :274-281
[10]   Volumetric-modulated arc radiotherapy for carcinomas of the anal canal: A treatment planning comparison with fixed field IMRT [J].
Clivio, Alessandro ;
Fogliata, Antonella ;
Franzetti-Pellanda, Alessandra ;
Nicolini, Giorgia ;
Vanetti, Eugenio ;
Wyttenbach, Rolf ;
Cozzi, Luca .
RADIOTHERAPY AND ONCOLOGY, 2009, 92 (01) :118-124