Method and device for non-invasive blood glucose measurement

被引:0
|
作者
Amerov, AK [1 ]
Jeon, KJ [1 ]
Kim, YJ [1 ]
Yoon, G [1 ]
机构
[1] Samsung Adv Inst Technol, Biomed Engn Res Ctr, Suwon 440600, South Korea
来源
OPTICAL DIAGNOSTICS OF BIOLOGICAL FLUIDS IV, PROCEEDINGS OF | 1999年 / 3599卷
关键词
glucose; non-invasive; NIR spectroscopy; wavelength selection;
D O I
10.1117/12.348382
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
The method and device for non-invasive measurement of blood glucose concentration based on the diffuse reflectance from the transcutaneous layers is proposed. Original normalizing ratio algorithm permitting to separate glucose absorption from absorption of other blood components is suggested. It was shown that the influence of water and some other components such as hemoglobin, albumin, globulin's and cholesterol concentration variations to the estimation of the glucose concentration can be compensated using spectral analysis of the reflection on several specially selected wavelengths and proposed algorithm. Device with optical geometry minimizing the effects of changes in the scattering background of biological tissues was developed. NIR spectral range 800 - 1800 nm was used because of its good transparency for biological tissue and presence of glucose absorption band. We used two kinds of light sources, namely LED array and Xe flash lamp. Tissue phantoms (different glucose concentration (0 - 1000 mg/dl) solutions with polystyrene beads or with milk) were used as samples. Scattering and absorption contribution to the dependence of diffuse reflection on glucose concentration was experimentally verified.
引用
收藏
页码:33 / 42
页数:4
相关论文
共 50 条
  • [21] Non-invasive Blood Glucose Measurement Based on mid-Infrared Spectroscopy
    Chen, Yang
    Liu, Jiang
    Pan, Zhenni
    Shimamoto, Shirgeru
    2020 IEEE 17TH ANNUAL CONSUMER COMMUNICATIONS & NETWORKING CONFERENCE (CCNC 2020), 2020,
  • [22] Non-invasive prediction of blood glucose trends during hypoglycemia
    Tronstad, Christian
    Elvebakk, Ole
    Staal, Odd Martin
    Kalvoy, Havard
    Hogetveit, Jan Olav
    Jenssen, Trond Geir
    Birkeland, Kare Inge
    Martinsen, Orjan G.
    ANALYTICA CHIMICA ACTA, 2019, 1052 : 37 - 48
  • [23] Instrumental requirements for non-invasive blood glucose measurement using NIR spectroscopy
    Arimoto, H
    Tarumi, M
    Yamada, Y
    OPTICAL REVIEW, 2003, 10 (03) : 161 - 165
  • [24] Development of Portable Non-invasive Blood Glucose Measuring Device Using NIR Spectroscopy
    Asekar, Megha S.
    PROCEEDINGS OF THE 2018 SECOND INTERNATIONAL CONFERENCE ON INTELLIGENT COMPUTING AND CONTROL SYSTEMS (ICICCS), 2018, : 572 - 575
  • [25] Non-invasive blood pressure measurement based on the electronic palpation method
    Nissilä, S
    Sorvisto, M
    Sorvoja, H
    Vieri-Gashi, E
    Myllylä, R
    PROCEEDINGS OF THE 20TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOL 20, PTS 1-6: BIOMEDICAL ENGINEERING TOWARDS THE YEAR 2000 AND BEYOND, 1998, 20 : 1723 - 1726
  • [26] Non-invasive blood glucose detection system based on conservation of energy method
    Zhang, Yang
    Zhu, Jian-ming
    Liang, Yong-bo
    Chen, Hong-bo
    Yin, Shi-min
    Chen, Zhen-cheng
    PHYSIOLOGICAL MEASUREMENT, 2017, 38 (02) : 325 - 342
  • [27] Continuous Non-invasive blood glucose monitoring by spectral image differencing method
    Huang, Hao
    Liao, Ningfang
    Cheng, Haobo
    Liang, Jing
    2017 INTERNATIONAL CONFERENCE ON OPTICAL INSTRUMENTS AND TECHNOLOGY - OPTOELECTRONIC MEASUREMENT TECHNOLOGY AND SYSTEMS, 2017, 10621
  • [28] Non-Invasive Blood Glucose Measurement Using Near Infra-Red Spectroscopy
    Priyoti, Anika Tabassum
    Jim, Salman Jubair
    Hossain, Sushmit
    Mahmud, Shafkat
    Salvin, Sujana
    Bhattacharjee, Arnab
    PROCEEDINGS OF 2019 IEEE R10 HUMANITARIAN TECHNOLOGY CONFERENCE (IEEE R10 HTC 2019), 2019, : 1 - 4
  • [29] Development of Sweat and Saliva Glucose Sensors as Alternative for Non-Invasive Blood Glucose Monitoring
    Lukito, Agrevina Ane
    Tyrayoh, Michelle
    Prasetyanto, Eko Adi
    Rukmini, Elisabeth
    INTERNATIONAL JOURNAL OF TECHNOLOGY, 2024, 15 (03) : 720 - 731
  • [30] An Antenna Loaded with Complementary Split Ring Resonator for Non-invasive Blood Glucose Measurement
    Lv, Zexiang
    Wang, Junjie
    Li, Gen
    2024 IEEE INTERNATIONAL INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE, I2MTC 2024, 2024,