Semi-analytical Modeling of the End-Winding Self-Inductance in Large AC Machines
被引:0
|
作者:
Grop, H.
论文数: 0引用数: 0
h-index: 0
机构:
Royal Inst Technol, Elect Energy Convers Dept, Stockholm, SwedenRoyal Inst Technol, Elect Energy Convers Dept, Stockholm, Sweden
Grop, H.
[1
]
Soulard, J.
论文数: 0引用数: 0
h-index: 0
机构:
Royal Inst Technol, Elect Energy Convers Dept, Stockholm, SwedenRoyal Inst Technol, Elect Energy Convers Dept, Stockholm, Sweden
Soulard, J.
[1
]
论文数: 引用数:
h-index:
机构:
Krings, A.
[1
]
Persson, H.
论文数: 0引用数: 0
h-index: 0
机构:
ABB Machines, Vasteras, SwedenRoyal Inst Technol, Elect Energy Convers Dept, Stockholm, Sweden
Persson, H.
[2
]
机构:
[1] Royal Inst Technol, Elect Energy Convers Dept, Stockholm, Sweden
[2] ABB Machines, Vasteras, Sweden
来源:
2012 15TH INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES AND SYSTEMS (ICEMS 2012)
|
2012年
关键词:
End-winding;
inductance;
leakage;
AC machines;
D O I:
暂无
中图分类号:
TM [电工技术];
TN [电子技术、通信技术];
学科分类号:
0808 ;
0809 ;
摘要:
A semi-analytical model for calculation of self-inductance of complex coil geometries having a rectangular cross-section (form-wound coils) is proposed and evaluated. A step-by-step validation is carried on using both 2D-FEM simulations and measurements on a coil placed in air. A second version of the model is developed, to speed up the computation time through removing the possibility to analyze the contribution of the internal flux in the conductor. The predicted value of the self-inductance of a diamond-shaped coil placed in air is within 5% of the measured value.