Use of vertebroplasty to prevent proximal junctional fractures in adult deformity surgery: a biomechanical cadaveric study

被引:90
作者
Kebaish, Khaled M. [1 ]
Martin, Christopher T. [1 ]
O'Brien, Joseph R. [1 ]
LaMotta, Ivan E. [1 ]
Voros, Gabor D. [1 ]
Belkoff, Stephen M. [1 ]
机构
[1] Johns Hopkins Univ, Sch Med, Dept Orthopaed Surg, Div Spine Surg, Baltimore, MD 21287 USA
关键词
Proximal junctional failure; Vertebral compression fracture; Long spinal fusion; Vertebroplasty; Complications; ADOLESCENT IDIOPATHIC SCOLIOSIS; VERTEBRAL AUGMENTATION; POSTERIOR INSTRUMENTATION; SPINAL INSTRUMENTATION; PEDICLE SCREW; FOLLOW-UP; FUSION; KYPHOSIS; LUMBAR; COMPLICATIONS;
D O I
10.1016/j.spinee.2013.06.039
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND CONTEXT: Vertebral compression fractures at the proximal junction are common complications of long spinal fusion surgeries that can contribute to the development of proximal junctional kyphosis or proximal junctional failure. To our knowledge, no biomechanical studies have addressed the effect of vertebral augmentation at the proximal junction. PURPOSE: To evaluate the effectiveness of prophylactic vertebroplasty in reducing the incidence of vertebral compression fractures at the proximal junction after a long spinal fusion in a cadaveric spine model. STUDY DESIGN: Biomechanical cadaveric study. METHODS: We divided 18 cadaveric spine specimens into three groups of six spines each: a control group, a group treated with one-level prophylactic vertebroplasty at the upper instrumented vertebra, and a group treated with two-level prophylactic vertebroplasty at the upper instrumented vertebra and the supra-adjacent vertebra. In all spines, the pedicles were instrumented from L5 to T10. Using eccentric axial loading, the specimens were then compressed until failure. Failure was defined as a precipitous decrease in load with increasing compression. The effect of augmentation on load-to-failure was checked using linear regression. The effect of augmentation on incidence of adjacent fractures was checked using logistic regression. Differences at the level of p<.05 were considered significant. KyphX cement introducer was donated by Kyphon, and the pedicle screws were donated by DePuy. RESULTS: Fractures occurred in 12 of 18 specimens: five in the control group, six in the one-level group, and only one in the two-level group; these differences were statistically significant. CONCLUSIONS: Prophylactic vertebroplasty at the upper instrumented level and its supra-adjacent vertebra reduced the incidence of junctional fractures after long posterior spinal instrumentation in this axially loaded cadaveric model. Additional studies are necessary to determine if these results are translatable to clinical practice. (C) 2013 Elsevier Inc. All rights reserved.
引用
收藏
页码:1897 / 1903
页数:7
相关论文
共 32 条
[1]   Adjacent vertebral failure after vertebroplasty - A biomechanical investigation [J].
Berlemann, U ;
Ferguson, SJ ;
Nolte, LP ;
Hein, PF .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2002, 84B (05) :748-752
[2]   Effect of vertebroplasty on pain relief, quality of life, and the incidence of new vertebral fractures: A 12-month randomized follow-up, controlled trial [J].
Blasco, Jordi ;
Martinez-Ferrer, Angeles ;
Macho, Juan ;
San Roman, Luis ;
Pomes, Jaume ;
Carrasco, Josep ;
Monegal, Ana ;
Guanabens, Nuria ;
Peris, Pilar .
JOURNAL OF BONE AND MINERAL RESEARCH, 2012, 27 (05) :1159-1166
[3]   What's new in spine surgery [J].
Bridwell, KH ;
Anderson, PA ;
Boden, SD ;
Vaccaro, AR ;
Zigler, JE .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2004, 86A (07) :1587-1594
[4]   A Randomized Trial of Vertebroplasty for Painful Osteoporotic Vertebral Fractures [J].
Buchbinder, Rachelle ;
Osborne, Richard H. ;
Ebeling, Peter R. ;
Wark, John D. ;
Mitchell, Peter ;
Wriedt, Chris ;
Graves, Stephen ;
Staples, Margaret P. ;
Murphy, Bridie .
NEW ENGLAND JOURNAL OF MEDICINE, 2009, 361 (06) :557-568
[5]   Complications in posterior fusion and instrumentation for degenerative lumbar scoliosis [J].
Cho, Kyu-Jung ;
Suk, Se-Il ;
Park, Seung-Rim ;
Kim, Jin-Hyok ;
Kim, Sung-Soo ;
Choi, Won-Kee ;
Lee, Kang-Yoon ;
Lee, Seung-Ryol .
SPINE, 2007, 32 (20) :2232-2237
[6]   Instrumentation-related complications of multilevel fusions for adult spinal deformity patients over age 65 - Surgical considerations and treatment option in patients with poor bone quality [J].
DeWald, Christopher J. ;
Stanley, Thomas .
SPINE, 2006, 31 (19) :S144-S151
[7]   Vertebroplasty and Vertebral Augmentation Techniques [J].
Eckel, Timothy S. ;
Olan, Wayne .
TECHNIQUES IN VASCULAR AND INTERVENTIONAL RADIOLOGY, 2009, 12 (01) :44-50
[8]   Proximal junctional vertebral fracture-subluxation after adult spine deformity surgery. Does vertebral augmentation avoid this complication? A case report [J].
Fernandez-Baillo, Nicomedes ;
Sanchez Marquez, Jose Miguel ;
Sanchez Perez-Grueso, Francisco Javier ;
Garcia Fernandez, Alfredo .
SCOLIOSIS AND SPINAL DISORDERS, 2012, 7
[9]   Incidence of subsequent vertebral fracture after kyphoplasty [J].
Fribourg, D ;
Tang, C ;
Delamarter, R ;
Bae, H .
SPINE, 2004, 29 (20) :2270-2276
[10]   Percutaneous Vertebral Augmentation: The Status of Vertebroplasty and Current Controversies [J].
Hargunani, Rikin ;
Le Corroller, Thomas ;
Khashoggi, Khalid ;
Murphy, Kieran J. ;