Monte Carlo radiation dose simulations and dosimetric comparison of the model 6711 and 9011 125I brachytherapy sources

被引:37
作者
Rivard, Mark J. [1 ]
机构
[1] Tufts Med Ctr, Dept Radiat Oncol, Boston, MA 02111 USA
关键词
biological organs; biomedical ultrasonics; brachytherapy; dosimetry; Monte Carlo methods; radioactive sources; PD-103; SEED; RECOMMENDATIONS; PARAMETERS; UPDATE; CS-131;
D O I
10.1118/1.3056463
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Smaller diameter brachytherapy seeds for permanent interstitial implantation allow for use of smaller diameter implant needles. The use of smaller diameter needles may provide a lower incidence of healthy-tissue complications. This study determines the brachytherapy dosimetry parameters for the smaller diameter source (model 9011) and comments on the dosimetric comparison between this new source and the conventional brachytherapy seed (model 6711).
引用
收藏
页码:486 / 491
页数:6
相关论文
共 16 条
[1]  
[Anonymous], 2003, MCNP GEN MONTE CARLO, V1.
[2]  
CULLEN DE, 1997, UCRL50440 LAWR LIV N, V6
[3]   Monte Carlo and experimental dosimetry of an 125I brachytherapy seed [J].
Dolan, James ;
Li, Zuofeng ;
Williamson, Jeffrey F. .
MEDICAL PHYSICS, 2006, 33 (12) :4675-4684
[4]   American Association of Physicists in Medicine radiation therapy committee task group 53: Quality assurance for clinical radiotherapy treatment planning [J].
Fraass, B ;
Doppke, K ;
Hunt, M ;
Kutcher, G ;
Starkschall, G ;
Stern, R ;
Van Dyke, J .
MEDICAL PHYSICS, 1998, 25 (10) :1773-1829
[5]   COMS eye plaque brachytherapy dosimetry simulations for 103Pd, 125I, and 131Cs [J].
Melhus, Christopher S. ;
Rivard, Mark J. .
MEDICAL PHYSICS, 2008, 35 (07) :3364-3371
[6]  
*NAT NUCL DAT CTR, NUDAT 2 0
[7]   DOSIMETRY OF INTERSTITIAL BRACHYTHERAPY SOURCES - RECOMMENDATIONS OF THE AAPM RADIATION-THERAPY COMMITTEE TASK GROUP NO 43 [J].
NATH, R ;
ANDERSON, LL ;
LUXTON, G ;
WEAVER, KA ;
WILLIAMSON, JF ;
MEIGOONI, AS .
MEDICAL PHYSICS, 1995, 22 (02) :209-234
[8]   Silver fluorescent x-ray yield and its influence on the dose rate constant for nine low-energy brachytherapy source models [J].
Nath, Ravinder ;
Chen, Zhe Jay .
MEDICAL PHYSICS, 2007, 34 (10) :3785-3793
[9]   Supplement to the 2004 update of the AAPM task group no. 43 report [J].
Rivard, Mark J. ;
Butler, Wayne M. ;
DeWerd, Larry A. ;
Huq, M. Saiful ;
Ibbott, Geoffrey S. ;
Meigooni, Ali S. ;
Melhus, Christopher S. ;
Mitch, Michael G. ;
Nath, Ravinder ;
Williamson, Jeffrey F. .
MEDICAL PHYSICS, 2007, 34 (06) :2187-2205
[10]   Brachytherapy dosimetry parameters calculated for a 131Cs source [J].
Rivard, Mark J. .
MEDICAL PHYSICS, 2007, 34 (02) :754-762