Modelling evaluation of the testing condition influence on the maximum stress induced in a hip prosthesis during ISO 7206 fatigue testing

被引:19
作者
Raimondi, MT [1 ]
Pietrabissa, R [1 ]
机构
[1] Politecn Milan, Lab Biol Struct Mech, Dipartimento Bioingn, I-20133 Milan, Italy
关键词
hip prosthesis; mechanical testing; fatigue; finite element model; standard;
D O I
10.1016/S1350-4533(99)00061-2
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In vivo fatigue failure of hip prosthesis stems has been extensively reported in literature. The ISO 7206 international standard has been developed to assess the fatigue reliability of hip prostheses. It describes the fatigue testing apparatus and procedure and it is currently adopted by several testing laboratories throughout the world. In this work we evaluate the maximum stress in a titanium alloy commercial stem in different testing conditions, ranging within the standard specification, using the finite element method applied to a 3D model of the stem. The calculated maximum von Mises stress ranges from +4.5 to -1.5% (for different cement constraint levels) and from +6.7 to -6.8% (for different stem angular orientations) with respect to that calculated at the nominal testing conditions. The results suggest that the ISO 7206 testing specification will give experimental data of reasonable accuracy, with probably no more scatter than that found in typical specimen test results. This is particularly important in the case of components manufactured from materials showing a fatigue resistance highly sensitive to stress variations, such as the Ti6Al4V alloy, for which a small increase of the maximum applied stress corresponds to a significant decrease of the statistical fatigue life. (C) 1999 IPEM, Published by Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:353 / 359
页数:7
相关论文
共 27 条
  • [1] [Anonymous], 7206 ISO
  • [2] BOYER HE, 1988, ATLAS CREEP STRESS R
  • [3] CHARNLEY J, 1975, CLIN ORTHOP RELAT R, V111, P105
  • [4] ROLE OF STEM DESIGN AND MATERIAL ON STRESS DISTRIBUTIONS IN CEMENTED TOTAL HIP-REPLACEMENT
    CHRISTEL, PS
    MEUNIER, A
    BLANQUAERT, D
    WITVOET, J
    SEDEL, L
    [J]. JOURNAL OF BIOMEDICAL ENGINEERING, 1988, 10 (01): : 57 - 63
  • [5] INFLUENCE OF GRAIN-SIZE ON THE FATIGUE BEHAVIOR OF ANNEALED 316 LVM STAINLESS-STEEL
    CLEMENS, D
    GALANTE, J
    ROSTOKER, W
    [J]. JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1979, 13 (03): : 437 - 441
  • [6] FATIGUE FAILURE OF NONCEMENTED POROUS-COATED IMPLANTS - A RETRIEVAL STUDY
    COOK, SD
    THOMAS, KA
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1991, 73 (01): : 20 - 24
  • [7] CROWNINSHIELD RD, 1986, AM ACAD ORTHOPAEDIC, V35, P145
  • [8] FATIGUE PROPERTIES OF IMPLANT MATERIALS IN HIP-PROSTHESIS FORM - A STANDARDIZED TEST
    DUCHEYNE, P
    WEVERS, M
    DEMEESTER, P
    [J]. JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1983, 17 (01): : 45 - 57
  • [9] FATIGUE FRACTURES OF FEMORAL COMPONENT OF CHARNLEY AND CHARNLEY-MULLER TYPE TOTAL HIP PROSTHESES
    DUCHEYNE, P
    DEMEESTER, P
    AERNOUDT, E
    MARTENS, M
    MULIER, JC
    [J]. JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1975, 9 (04): : 199 - 219
  • [10] PERFORMANCE ANALYSIS OF TOTAL HIP PROSTHESES - SOME PARTICULAR METALLURGICAL OBSERVATIONS
    DUCHEYNE, P
    DEMEESTER, P
    AERNOUDT, E
    [J]. JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1980, 14 (01): : 31 - 40