Beam based alignment and its relevance in Indus-2

被引:4
作者
Jena, Saroj Kumar [1 ]
Husain, Riyasat [1 ]
Gandhi, M. L. [1 ]
Agrawal, R. K. [1 ]
Yadav, S. [1 ]
Ghodke, A. D. [1 ]
机构
[1] Raja Ramanna Ctr Adv Technol, Indore, Madhya Pradesh, India
关键词
Magnets;
D O I
10.1063/1.4930277
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Initially in the Indus-2 storage ring, the closed orbit distortion (COD) could be best corrected to 1.3 mm rms in the horizontal and 0.43 mm rms in the vertical plane. The strength of the corrector magnets required high values for COD correction. This revealed that offsets in COD readout by the beam position monitors (BPMs) played a role in not achieving a rms COD lower than the above value. Thus, the offset between the electrical center of BPMs and the magnetic center of the nearest quadrupole magnet could be estimated using the beam based alignment (BBA) method. It prefers that the quadrupole magnet is able to be controlled individually and active shunt power supply (ASPS) system was designed for this purpose that works efficiently. This paper describes the methodology of BBA, topology of ASPS and its performance, and COD minimization using the measured BPM offsets. After BBA, the COD could be reduced to 0.45 mm rms and 0.2 mm rms in horizontal and vertical planes, respectively. (C) 2015 AIP Publishing LLC.
引用
收藏
页数:6
相关论文
共 10 条
[1]  
Agrawal R. K., 2005, SOFTWARE SCENARIO CO
[2]  
Fatnani P., INDUS 2 CONTROL SYST
[3]  
Gandhi M. L., 2014, P 9 IEEE INT C IND I
[4]   Measurement of parameters in Indus-2 synchrotron radiation source [J].
Ghodke, A. D. ;
Husain, Riyasat ;
Kumar, Pradeep ;
Yadav, Surendra ;
Puntambekar, T. A. .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2012, 83 (10)
[5]   Measurement, analysis and correction of the closed orbit distortion in Indus-2 synchrotron radiation source [J].
Husain, Riyasat ;
Ghodke, A. D. ;
Yadav, Surendra ;
Holikatti, A. C. ;
Yadav, R. P. ;
Fatnani, P. ;
Puntambekar, T. A. ;
Hannurkar, P. R. .
PRAMANA-JOURNAL OF PHYSICS, 2013, 80 (02) :263-275
[6]  
Man-Zhou Z., 2009, CHINESE PHYS C, V33, P301
[7]  
PORTMANN G, 1995, PART ACC C P 1995 DA, V4, P2693
[9]   Corrector-based magnet alignment procedure [J].
Sjostrom, M. ;
Wallen, E. ;
Eriksson, M. ;
Lindgren, L. -J. .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2008, 597 (2-3) :170-177
[10]   Estimation and measurement of effective beam position monitor offsets by using a stored beam [J].
Soutome, K ;
Tanaka, H ;
Takao, M ;
Ohkuma, H ;
Kumagai, N .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 459 (1-2) :66-77