Quantitative evaluation of models for solvent-based, on-column focusing in liquid chromatography

被引:32
作者
Groskreutz, Stephen R. [1 ]
Weber, Stephen G. [1 ]
机构
[1] Univ Pittsburgh, Dept Chem, Pittsburgh, PA 15260 USA
基金
美国国家科学基金会; 美国国家卫生研究院;
关键词
Volume overload; On-column focusing; Large volume injections; Capillary HPLC; SAMPLE VOLUME; DETECTION SENSITIVITY; INJECTION TECHNIQUES; MICROBORE COLUMNS; PERFORMANCE; OPTIMIZATION; MICRODIALYSIS; SEPARATIONS; TEMPERATURE; RESOLUTION;
D O I
10.1016/j.chroma.2015.07.038
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
On-column focusing or preconcentration is a well-known approach to increase concentration sensitivity by generating transient conditions during the injection that result in high solute retention. Preconcentration results from two phenomena: (I) solutes are retained as they enter the column. Their velocities are k'-dependent and lower than the mobile phase velocity and (2) zones are compressed due to the step-gradient resulting from the higher elution strength mobile phase passing through the solute zones. Several workers have derived the result that the ratio of the eluted zone width (in time) to the injected time width is the ratio k(2)/k(1), where 10 is the retention factor of a solute in the sample solvent and k(2) is the retention factor in the mobile phase (isocratic). Mills et al. proposed a different factor. To date, neither of the models has been adequately tested. The goal of this work was to evaluate quantitatively these two models. We used n-alkyl esters of p-hydroxybenzoic acid (parabens) as solutes. By making large injections to create obvious volume overload, we could measure accurately the ratio of widths (eluted/injected) over a range of values of k(1) and k(2). The Mills et al. model does not fit the data. The data are in general agreement with the factor k(2)/k(1), but focusing is about 10% better than the prediction. We attribute the extra focusing to the fact that the second, compression, phenomenon provides a narrower zone than that expected for the passage of a step gradient through the zone. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:116 / 124
页数:9
相关论文
共 32 条
[1]   Choosing sample volume to achieve maximum detection sensitivity and resolution with high-performance liquid chromatography columns of 1.0, 2.1 and 4.6 mm ID [J].
Bakalyar, SR ;
Phipps, C ;
Spruce, B ;
Olsen, K .
JOURNAL OF CHROMATOGRAPHY A, 1997, 762 (1-2) :167-185
[2]   Influence of pressure and temperature on the physico-chemical properties of mobile phase mixtures commonly used in high-performance liquid chromatography [J].
Billen, Jeroen ;
Broeckhoven, Ken ;
Liekens, Anuschka ;
Choikhet, Konstantin ;
Rozing, Gerard ;
Desmet, Gert .
JOURNAL OF CHROMATOGRAPHY A, 2008, 1210 (01) :30-44
[3]   Separation of organophosphorus pesticides by using nano-liquid chromatography [J].
Buonasera, Katia ;
D'Orazio, Giovanni ;
Fanali, Salvatore ;
Dugo, Paola ;
Mondello, Luigi .
JOURNAL OF CHROMATOGRAPHY A, 2009, 1216 (18) :3970-3976
[4]   A COMPARATIVE-STUDY OF LARGE VOLUME INJECTION TECHNIQUES FOR MICROBORE COLUMNS IN HPLC [J].
CLAESSENS, HA ;
KUYKEN, MAJ .
CHROMATOGRAPHIA, 1987, 23 (05) :331-336
[5]   Peak refocusing using subsequent retentive trapping and strong eluent remobilization in liquid chromatography: A theoretical optimization study [J].
De Vos, Jelle ;
Eeltink, Sebastiaan ;
Desmet, Gert .
JOURNAL OF CHROMATOGRAPHY A, 2015, 1381 :74-86
[6]   A generic approach to post-column refocusing in liquid chromatography [J].
De Vos, Jelle ;
Desmet, Gert ;
Eeltink, Sebastiaan .
JOURNAL OF CHROMATOGRAPHY A, 2014, 1360 :164-171
[7]   Performance of experimental sample injectors for high-performance liquid chromatography microcolumns [J].
Foster, MD ;
Arnold, MA ;
Nichols, JA ;
Bakalyar, SR .
JOURNAL OF CHROMATOGRAPHY A, 2000, 869 (1-2) :231-241
[8]   Influence of injection parameters on column performance in nanoscale high-performance liquid chromatography [J].
Héron, S ;
Tchapla, A ;
Chervet, JP .
CHROMATOGRAPHIA, 2000, 51 (7-8) :495-499
[9]  
Hilhorst MJ, 2001, CHROMATOGRAPHIA, V53, P190
[10]   ZONE COMPRESSION EFFECTS IN HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
HSU, SH ;
RAGLIONE, T ;
TOMELLINI, SA ;
FLOYD, TR ;
SAGLIANO, N ;
HARTWICK, RA .
JOURNAL OF CHROMATOGRAPHY, 1986, 367 (02) :293-300