Bioanalytical LC-MS/MS of protein-based biopharmaceuticals

被引:174
作者
van den Broek, Irene [1 ]
Niessen, Wilfried M. A. [2 ,3 ]
van Dongen, William D. [1 ]
机构
[1] TNO Triskel, NL-3704 AV Zeist, Netherlands
[2] Hyphen MassSpec, NL-2332 XT Leiden, Netherlands
[3] Vrije Univ Amsterdam, Fac Sci, AIMMS Div BioMol Anal, NL-1081 HV Amsterdam, Netherlands
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2013年 / 929卷
关键词
Bioanalysis; LC-MS; Monoclonal antibodies; Therapeutic protein; Absolute quantification; Sample preparation; TANDEM MASS-SPECTROMETRY; PEPTIDE IMMUNOAFFINITY ENRICHMENT; THERAPEUTIC MONOCLONAL-ANTIBODIES; PROSTATE-SPECIFIC ANTIGEN; RECOMBINANT-HUMAN-ERYTHROPOIETIN; ORTHOGONAL ARRAY OPTIMIZATION; FUSION INHIBITOR ENFUVIRTIDE; HUMAN CHORIONIC-GONADOTROPIN; HUMAN GROWTH-HORMONE; C-REACTIVE PROTEIN;
D O I
10.1016/j.jchromb.2013.04.030
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Biotechnology increasingly delivers highly promising protein-based biopharmaceutical candidates to the drug development funnel. For successful biopharmaceutical drug development, reliable bioanalytical methods enabling quantification of drugs in biological fluids (plasma, urine, tissue, etc.) are required to generate toxicokinetic (TK), pharmacokinetic (PK), and bioavailability data. A clear observable trend is that liquid chromatography coupled to (tandem) mass spectrometry (LC-MS(/MS)) is more and more replacing ligand binding assays (LBA) for the bioanalytical determination of protein-based biopharmaceuticals in biological matrices, mainly due to improved selectivity and linear dynamic ranges. Practically all MS-based quantification methods for protein-based biopharmaceuticals traditionally rely on (targeted) proteomic techniques and include "seven critical factors": (1) internal standardization, (2) protein purification, (3) enzymatic digestion, (4) selection of signature peptide(s), (5) peptide purification, (6) liquid chromatographic separation and (7) mass spectrometric detection. For this purpose, the variety of applied strategies for all "seven critical factors" in current literature on MS-based protein quantification have been critically reviewed and evaluated. Special attention is paid to the quantification of therapeutic monoclonal antibodies (mAbs) in serum and plasma since this is a very promising and rapidly expanding group of biopharmaceuticals. Additionally, the review aims to predict the impact of strategies moving away from traditional protein cleavage isotope dilution mass spectrometry (PC-IDMS) toward approaches that are more dedicated to bioanalysis. (C) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:161 / 179
页数:19
相关论文
共 193 条
[61]   Targeted Proteomic Quantification on Quadrupole-Orbitrap Mass Spectrometer [J].
Gallien, Sebastien ;
Duriez, Elodie ;
Crone, Catharina ;
Kellmann, Markus ;
Moehring, Thomas ;
Domon, Bruno .
MOLECULAR & CELLULAR PROTEOMICS, 2012, 11 (12) :1709-1723
[62]  
Garcia-Garcia Idrian, 2010, BMC Pharmacology, V10, P15, DOI 10.1186/1471-2210-10-15
[63]   Electron Transfer Dissociation Mass Spectrometry of Hemoglobin on Clinical Samples [J].
Graca, Didia Coelho ;
Lescuyer, Pierre ;
Clerici, Lorella ;
Tsybin, Yury O. ;
Hartmer, Ralf ;
Meyer, Markus ;
Samii, Kaveh ;
Hochstrasser, Denis F. ;
Scherl, Alexander .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2012, 23 (10) :1750-1756
[64]  
GUAN F, 2010, J CHEN ANAL CHEM
[65]   LC-MS/MS method for confirmation of recombinant human erythropoietin and darbepoetin α in equine plasma [J].
Guan, Fuyu ;
Uboh, Cornelius E. ;
Soma, Lawrence R. ;
Birks, Eric ;
Chen, Jinwen ;
Mitchell, Janis ;
You, Youwen ;
Rudy, Jeffrey ;
Xu, Fran ;
Li, Xiaoqing ;
Mbuy, Gustave .
ANALYTICAL CHEMISTRY, 2007, 79 (12) :4627-4635
[66]   Absolute quantification of monoclonal antibodies in biofluids by liquid chromatography-tandem mass spectrometry [J].
Hagman, Charlotte ;
Ricke, Darrell ;
Ewert, Stefan ;
Bek, Stephan ;
Falchetto, Rocco ;
Bitsch, Francis .
ANALYTICAL CHEMISTRY, 2008, 80 (04) :1290-1296
[67]   Determination of oxyntomodulin, an anorectic polypeptide, in rat plasma using 2D-LC-MS/MS coupled with ion pair chromatography [J].
Halquist, Matthew S. ;
Sakagami, Masahiro ;
Karnes, H. Thomas .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2012, 903 :102-111
[68]   Quantification of Alefacept, an immunosuppressive fusion protein in human plasma using a protein analogue internal standard, trypsin cleaved signature peptides and liquid chromatography tandem mass spectrometry [J].
Halquist, Matthew S. ;
Karnes, H. Thomas .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2011, 879 (11-12) :789-798
[69]   An improved LC-MS/MS method for the determination of taspoglutide in plasma and urine using orthogonal HILIC-RP column switching, ultra-performance LC separation and 'wrong-way-round' electrospray ionization [J].
Heinig, Katja ;
Wirz, Thomas ;
Yuan, Moucun ;
Tingler, Michael ;
Mylott, William .
BIOMEDICAL CHROMATOGRAPHY, 2011, 25 (11) :1215-1221
[70]   Towards absolute quantification of therapeutic monoclonal antibody in serum by LC-MS/MS using isotope-labeled antibody standard and protein cleavage isotope dilution mass spectrometry [J].
Heudi, Olivier ;
Barteau, Samuel ;
Zimmer, Dieter ;
Schmidt, Joerg ;
Bill, Kurt ;
Lehmann, Natalie ;
Bauer, Christian ;
Kretz, Olivier .
ANALYTICAL CHEMISTRY, 2008, 80 (11) :4200-4207