Emission characteristic of polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans (PCDD/Fs) from medical waste incinerators (MWIs) in China in 2016: A comparison between higher emission levels of MWIs and lower emission levels of MWIs

被引:42
作者
Li, Jiafu [1 ]
Lv, Zhiwei [2 ]
Du, Lei [1 ]
Li, Xiaonan [1 ]
Hu, Xuepeng [1 ]
Wang, Chong [1 ]
Niu, Zhiguang [1 ,2 ]
Zhang, Ying [3 ]
机构
[1] Tianjin Univ, Sch Environm Sci & Engn, Tianjin 300072, Peoples R China
[2] Tianjin Univ, Sch Marine Sci & Technol, Tianjin 300072, Peoples R China
[3] Nankai Univ, Coll Environm Sci & Engn, MOE Key Lab Pollut Proc & Environm Criteria, Tianjin 300350, Peoples R China
关键词
PCDD/Fs; Stack gas; Emissions; TEQ indicators; Medical waste incinerators; HUMAN EXPOSURE; HEALTH-RISK; FLY-ASH; PCBS; VICINITY; MANAGEMENT; SEDIMENTS; MODEL; KOREA;
D O I
10.1016/j.envpol.2016.12.009
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Emission characteristic of polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans (PCDD/ Fs) from 12 medical waste incinerators (MWIs) which have a total yearly capacity of 523 440 ton medical waste and accounted for 8.1% of total yearly capacity of 246 MWIs in China were studied. The congeners profile, emissions and toxic equivalent concentrations (TEQ) indicators of PCDD/Fs in stack gas from two groups of MWIs were researched, and the possible formation mechanisms of PCDD/Fs from MWIs were preliminarily discussed. The results of present study were summarized as follows. (1) The total concentrations and TEQ of PCDD/Fs in stack gas from MWIs were 0.516-122.803 ng Nm(-3) and 0.031 3.463 ng I-TEQ Nm(-3), respectively. (2) 1,2,3,4,6,7,8-H7CDF, 08CDD, O8CDF and 1,2,3,4,6,7,8-H7CDD were the indicatory PCDD/Fs of MWI source, which could be used to apportion the sources of PCDD/Fs in environmental medium in China. (3) The emission factors of PCDD/Fs from MWIs ranged from 32.7 to 4900.0 ng I-TEQ ton(-1) with a mean of 1923.6 ng I-TEQ ton(-1). (4) The gas emissions of PCDD/Fs from researched 12 MWIs and all of MWIs in China in 2016 were 37.742 and 465.951 mg I-TEQ year(-1) respectively. (5) 1,2,3,7,8,9-H6CDF and 1,2,3,4,7,8-H6CDF were effective TEQ indicators for the real-time monitoring of the PCDD/Fs emission. (6) The congeners profile and factor composition of PCDD/Fs in stack gas from two groups of MWIs were researched based on positive matrix factorization (PMF) model, and the possible formation mechanisms of PCDD/Fs from MWIs were preliminarily discussed. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:437 / 444
页数:8
相关论文
共 29 条
[1]   Ranking municipal solid waste treatment alternatives considering sustainability criteria using the analytical hierarchical process tool [J].
Antonopoulos, I. -S. ;
Perkoulidis, G. ;
Logothetis, D. ;
Karkanias, C. .
RESOURCES CONSERVATION AND RECYCLING, 2014, 86 :149-159
[2]   Influence of non-detect data-handling on toxic equivalency quantities of PCDD/Fs and dioxin-like PCBs: A case study of major fish species purchased in Korea [J].
Barghi, Mandana ;
Choi, Sung-Deuk ;
Kwon, Hye-Ok ;
Lee, Yun-Se ;
Chang, Yoon-Seok .
ENVIRONMENTAL POLLUTION, 2016, 214 :532-538
[3]  
[陈佳 Chen Jia], 2014, [环境科学学报, Acta Scientiae Circumstantiae], V34, P973
[4]   Medical waste production at hospitals and associated factors [J].
Cheng, Y. W. ;
Sung, F. C. ;
Yang, Y. ;
Lo, Y. H. ;
Chung, Y. T. ;
Li, K. -C. .
WASTE MANAGEMENT, 2009, 29 (01) :440-444
[5]   Health risks for the population living in the vicinity of an Integrated Waste Management Facility: Screening environmental pollutants [J].
Domingo, Jose L. ;
Rovira, Joaquim ;
Vilavert, Lolita ;
Nadal, Marti ;
Figueras, Maria J. ;
Schuhmacher, Marta .
SCIENCE OF THE TOTAL ENVIRONMENT, 2015, 518 :363-370
[6]   A Critical Review about Human Exposure to Polychlorinated Dibenzo-p-Dioxins (PCDDs), Polychlorinated Dibenzofurans (PCDFs) and Polychlorinated Biphenyls (PCBs) through Foods [J].
Fernandez-Gonzalez, R. ;
Yebra-Pimentel, I. ;
Martinez-Carballo, E. ;
Simal-Gandara, J. .
CRITICAL REVIEWS IN FOOD SCIENCE AND NUTRITION, 2015, 55 (11) :1590-1617
[7]   Stack gas emissions of PCDD/Fs from hospital waste incinerators in China [J].
Gao, Hongcai ;
Ni, Yuwen ;
Zhang, Haijun ;
Zhao, Liang ;
Zhang, Ning ;
Zhang, Xueping ;
Zhang, Qing ;
Chen, Jiping .
CHEMOSPHERE, 2009, 77 (05) :634-639
[8]   Comparison of 2,4,6-trichlorophenol conversion to PCDD/PCDF on a MSWI-fly ash and a model fly ash [J].
Hell, K ;
Altwicker, ER ;
Stieglitz, L ;
Addink, R .
CHEMOSPHERE, 2000, 40 (9-11) :995-1001
[9]   Total suspended particulate (TSP), polychlorinated dibenzodioxin (PCDD) and polychlorinated dibenzofuran (PCDF) emissions from medical waste incinerators in Antioquia, Colombia [J].
Hoyos, A. ;
Cobo, M. ;
Aristizabal, B. ;
Cordoba, F. ;
Montes de Correa, C. .
CHEMOSPHERE, 2008, 73 (01) :S137-S142
[10]   Medical waste management in Korea [J].
Jang, Yong-Chul ;
Lee, Cargro ;
Yoon, Oh-Sub ;
Kim, Hwidong .
JOURNAL OF ENVIRONMENTAL MANAGEMENT, 2006, 80 (02) :107-115