Enantioselective assay for the determination of perhexiline enantiomers in human plasma by liquid chromatography

被引:14
作者
Davies, BJ
Herbert, MK
Culbert, JA
Pyke, SM
Coller, JK
Somogyi, AA
Milne, RW
Sallustio, BC
机构
[1] Queen Elizabeth Hosp, Dept Cardiol & Clin Pharmacol, Woodville, SA 5011, Australia
[2] Univ Adelaide, Dept Expt & Clin Pharmacol, Adelaide, SA 5005, Australia
[3] Univ Adelaide, Sch Chem & Phys, Adelaide, SA 5005, Australia
[4] Univ S Australia, Sansom Inst, Adelaide, SA 5000, Australia
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2006年 / 832卷 / 01期
关键词
enantiomer separation; HPLC; perhexiline;
D O I
10.1016/j.jchromb.2005.12.046
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Effective use of the antianginal agent perhexiline is difficult because saturable metabolism by the polymorphic cytochrome P450 2D6 (CYP2D6) isoform produces elevated plasma perhexiline concentrations that have been associated with serious hepatic and neurological toxicity. Perhexiline is marketed for therapeutic use as a racemate and there is evidence for differences in the disposition of its enantiomers. The current study describes an enantioselective HPLC-fluorescent method utilising pre-column derivatization with (R)-(-)-1-(1-napthyl)ethyl isocyanate. Following derivatization, the enantiomers are resolved on a C18 column with gradient elution using a mobile phase composed of methanol and water. The method described is suitable for the quantification of (+)- and (-)-perhexiline in human plasma following clinical doses and demonstrates sufficient sensitivity, accuracy and precision between 0.01 and 2.00 mg/l for each enantiomer, with intra-assay coefficients of variation and bias < 20% at 0.01 mg/l and < 10% at 2.00 mg/l, and inter-assay coefficients of variation and biases < 15% at 0.03 mg/l and < 10% at 0.40 and 0.75 mg/l. The application of this method to plasma samples collected from a patient treated with perhexiline revealed that (+)-perhexiline concentrations were higher than (-)-perhexiline concentrations, confirming the stereoselective disposition of perhexiline. The current study describes an enantioselective method that milises pre-column formation of fluorescent diastereomers that are resolved on a C18 HPLC column using a gradient of methanol and water. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:114 / 120
页数:7
相关论文
共 16 条
[1]  
Bianchetti G, 1977, 1,1Dicyclohexyl-2-(2-piperidyl) ethane, Patent No. [DE 2643473, 2643473]
[2]   CLINICAL EVALUATION OF PERHEXILINE MALEATE IN PATIENTS WITH ANGINA PECTORIS [J].
BURNSCOX, CJ ;
CHANDRASEKHAR, KP ;
IKRAM, H ;
PEIRCE, TH ;
PILCHER, J ;
QUINLAN, CDM ;
REES, JR .
BMJ-BRITISH MEDICAL JOURNAL, 1971, 4 (5787) :586-+
[3]   EFFICACY AND SAFETY OF PERHEXILINE-MALEATE IN REFRACTORY ANGINA - A DOUBLE-BLIND PLACEBO-CONTROLLED CLINICAL-TRIAL OF A NOVEL ANTIANGINAL AGENT [J].
COLE, PL ;
BEAMER, AD ;
MCGOWAN, N ;
CANTILLON, CO ;
BENFELL, K ;
KELLY, RA ;
HARTLEY, LH ;
SMITH, TW ;
ANTMAN, EM .
CIRCULATION, 1990, 81 (04) :1260-1270
[4]   POLYMORPHIC HYDROXYLATION OF PERHEXILINE-MALEATE IN MAN [J].
COOPER, RG ;
EVANS, DAP ;
WHIBLEY, EJ .
JOURNAL OF MEDICAL GENETICS, 1984, 21 (01) :27-33
[5]   STEREOSELECTIVE PHARMACOKINETICS OF PERHEXILINE [J].
GOULD, BJ ;
AMOAH, AGB ;
PARKE, DV .
XENOBIOTICA, 1986, 16 (05) :491-502
[6]   HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC ASSAY OF PERHEXILINE-MALEATE IN PLASMA [J].
HOROWITZ, JD ;
MORRIS, PM ;
DRUMMER, OH ;
GOBLE, AJ ;
LOUIS, WJ .
JOURNAL OF PHARMACEUTICAL SCIENCES, 1981, 70 (03) :320-322
[7]   PERHEXILINE-MALEATE TREATMENT FOR SEVERE ANGINA-PECTORIS - CORRELATIONS WITH PHARMACOKINETICS [J].
HOROWITZ, JD ;
SIA, STB ;
MACDONALD, PS ;
GOBLE, AJ ;
LOUIS, WJ .
INTERNATIONAL JOURNAL OF CARDIOLOGY, 1986, 13 (02) :219-229
[8]  
JACQUES J, 1971, TETRAHEDRON LETT, V48, P4617
[9]   IMPAIRED OXIDATION OF DEBRISOQUINE IN PATIENTS WITH PERHEXILINE LIVER-INJURY [J].
MORGAN, MY ;
RESHEF, R ;
SHAH, RR ;
OATES, NS ;
SMITH, RL ;
SHERLOCK, S .
GUT, 1984, 25 (10) :1057-1064
[10]  
OATES NS, 1984, BRIT J CLIN PHARMACO, V18, pP307