Hemoglobin measurement prior to initiating copper intrauterine devices: a systematic review

被引:7
|
作者
Tepper, Naomi K. [1 ]
Steenland, Maria W. [1 ]
Marchbanks, Polly A. [1 ]
Curtis, Kathryn M. [1 ]
机构
[1] Ctr Dis Control & Prevent, Div Reprod Hlth, Atlanta, GA 30341 USA
关键词
Hemoglobin; Anemia; Copper intrauterine device; Systematic review; MENSTRUAL BLOOD-LOSS; IRON-DEFICIENCY; CONTRACEPTIVE DEVICES; SERUM FERRITIN; SURFACE-AREA; TCU; 380AG; LEVONORGESTREL; INSERTION; ANEMIA; IUD;
D O I
10.1016/j.contraception.2012.08.008
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Background: Women using copper intrauterine devices (IUDs) frequently experience bleeding abnormalities. This review was conducted to evaluate the evidence regarding whether hemoglobin levels should be measured prior to copper IUD insertion. Study Design: The PubMed database was searched from database inception through March 2012 for all peer-reviewed articles in any language concerning hemoglobin changes among women with anemia who have copper IUDs inserted. Articles were included if they reported changes in hemoglobin among anemic women over a specified period of time following copper IUD insertion. Articles were excluded in which there were no women with anemia at baseline or outcomes among women with anemia were not reported separately. For indirect evidence, articles were included which addressed hemoglobin changes among women without anemia who had copper IUDs inserted. The quality of each direct study was assessed using the US Preventive Services Task Force grading system. Results: Four level I to II-2 studies of fair quality met inclusion criteria as direct evidence. Evidence from one randomized trial and one prospective cohort study showed no statistically significant changes in hemoglobin among copper IUD users with anemia, while two prospective cohort studies showed a statistically significant, but clinically small, mean decrease in hemoglobin levels over 12 months of follow-up. We also identified 21 studies examining changes in hemoglobin among healthy women using copper IUDs as indirect evidence; this body of evidence was not graded. These studies generally showed no clinically significant changes in hemoglobin levels with up to 5 years of follow-up. Conclusions: Limited fair-quality evidence was mixed but generally showed no clinically significant changes in hemoglobin among women with anemia who used copper IUDs for up to 12 months. Indirect evidence among healthy women using copper IUDs did not show clinically significant changes in hemoglobin levels when followed for up to 5 years of use. Published by Elsevier Inc.
引用
收藏
页码:639 / 644
页数:6
相关论文
共 50 条
  • [1] Hemoglobin and serum ferritin levels in women using copper-releasing or levonorgestrel-releasing intrauterine devices: a systematic review
    Lowe, Richard F.
    Prata, Ndola
    CONTRACEPTION, 2013, 87 (04) : 486 - 496
  • [2] Intrauterine devices for adolescents: a systematic review
    Deans, Elizabeth I.
    Grimes, David A.
    CONTRACEPTION, 2009, 79 (06) : 418 - 423
  • [3] Blood pressure measurement prior to initiating hormonal contraception: a systematic review
    Tepper, Naomi K.
    Curtis, Kathryn M.
    Steenland, Maria W.
    Marchbanks, Polly A.
    CONTRACEPTION, 2013, 87 (05) : 631 - 638
  • [4] Interventions for increasing uptake of copper intrauterine devices: systematic review and meta-analysis
    Arrowsmith, Myat E.
    Aicken, Catherine R. H.
    Majeed, Azeem
    Saxena, Sonia
    CONTRACEPTION, 2012, 86 (06) : 600 - 605
  • [5] Comparison of levonorgestrel in different forms and copper intrauterine devices for emergency contraception: A systematic review and meta-analysis
    Gaio, Giovana de Souza
    Kemczenski, Frederico
    Erzinger, Gabriel
    de Oliveira, Helen Michaela
    Farias, Caroline Freitas
    Chagas, Junea
    EUROPEAN JOURNAL OF OBSTETRICS & GYNECOLOGY AND REPRODUCTIVE BIOLOGY, 2025, 305 : 153 - 158
  • [6] The efficacy of intrauterine devices for emergency contraception and beyond: a systematic review update
    Goldstuck, Norman D.
    Cheung, Tik Shan
    INTERNATIONAL JOURNAL OF WOMENS HEALTH, 2019, 11 : 471 - 479
  • [7] The safety of intrauterine devices in breastfeeding women: a systematic review
    Berry-Bibee, Erin N.
    Tepper, Naomi K.
    Jatlaoui, Tara C.
    Whiteman, Maura K.
    Jamieson, Denise J.
    Curtis, Kathryn M.
    CONTRACEPTION, 2016, 94 (06) : 725 - 738
  • [8] Copper-containing, framed intrauterine devices for contraception: A systematic review of randomized controlled trials
    O'Brien, Paul A.
    Kulier, Regina
    Helmerhorst, Frans M.
    Usher-Patel, Margaret
    d'Arcangues, Catherine
    CONTRACEPTION, 2008, 77 (05) : 318 - 327
  • [9] Physical examination prior to initiating hormonal contraception: a systematic review
    Tepper, Naomi K.
    Curtis, Kathryn M.
    Steenland, Maria W.
    Marchbanks, Polly A.
    CONTRACEPTION, 2013, 87 (05) : 650 - 654
  • [10] Spine Surgery and Preoperative Hemoglobin, Hematocrit, and Hemoglobin A1c: A Systematic Review
    Suresh, Krishna V.
    Wang, Kevin
    Sethi, Ishaan
    Zhang, Bo
    Margalit, Adam
    Puvanesarajah, Varun
    Jain, Amit
    GLOBAL SPINE JOURNAL, 2022, 12 (01) : 155 - 165