Whole-body dose equivalent including neutrons is similar for 6 MV and 15 MV IMRT, VMAT, and 3D conformal radiotherapy

被引:20
作者
Hauri, Pascal [1 ,2 ]
Schneider, Uwe [1 ,2 ]
机构
[1] Univ Zurich, Dept Phys, Zurich, Switzerland
[2] Hirslanden Med Ctr, Radiotherapy Hirslanden, Aarau, Switzerland
来源
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS | 2019年 / 20卷 / 03期
关键词
radiotherapy; 15 MV vs 6 MV; out-of-field dose; neutron dose equivalent; MODULATED RADIATION-THERAPY; DYNAMIC MLC IMRT; PHOTON BEAMS; CONSTITUENT COMPONENTS; DELIVERY TECHNIQUES; TREATMENT MACHINES; SPECTRA; MODEL; DOSIMETERS; SCATTER;
D O I
10.1002/acm2.12543
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose This study investigates the difference in whole-body dose equivalent between 6 and 15 MV image-guided radiotherapy (IGRT) for the treatment of a rhabdomyosarcoma in the prostate. Methods A previously developed model for stray radiation of the primary beam was improved and used to calculate the photon dose and photon energy in the out-of-field region for a radiotherapy patient. The dose calculated by the treatment planning system was fused with the model-calculated out-of-field dose, resulting in a whole-body photon dose distribution. The peripheral neutron dose equivalent was calculated using an analytical model from the literature. A daily cone beam CT dose was added to the neutron and photon dose equivalents. The calculated 3D dose distributions were compared to independent measurements conducted with thermoluminescence dosimeters and an anthropomorphic phantom. The dose contributions from the IGRT treatments of three different techniques applied with two nominal X-ray energies were compared using dose equivalent volume histograms (DEVHs). Results The calculated and measured out-of-field whole-body dose equivalents for the IGRT treatments agreed within (9 +/- 10) % (mean and type A SD). The neutron dose equivalent was a minor contribution to the total out-of-field dose up to 50 cm from the isocenter. Further from the isocenter, head leakage was dominating inside the patient body, whereas the neutron dose equivalent contribution was important close to the surface. There were small differences between the whole-body DEVHs of the 6 and 15 MV treatments applied with the same technique, although the single scatter contributions showed large differences. Independent of the beam energy, the out-of-field dose of the volumetric-modulated arc therapy (VMAT) treatment was significantly lower than the dynamic intensity-modulated radiation therapy (IMRT) treatment. Conclusion The calculated whole-body dose helped to understand the importance of the dose contributions in different areas of the patient. Regarding radiation protection of the patient for IGRT treatments, the choice of beam energy is not important, whereas the treatment technique has a large influence on the out-of-field dose. If the patient is treated with intensity-modulated beams, VMAT should be used instead of dynamic IMRT in terms of radiation protection of the patient. In general, the developed models for photon and neutron dose equivalent calculation can be used for any patient geometry, tumor location, and linear accelerator.
引用
收藏
页码:56 / 70
页数:15
相关论文
共 44 条
  • [31] A COMPARISON OF OUT-OF-FIELD DOSE AND ITS CONSTITUENT COMPONENTS FOR INTENSITY-MODULATED RADIATION THERAPY VERSUS CONFORMAL RADIATION THERAPY: IMPLICATIONS FOR CARCINOGENESIS
    Ruben, Jeremy D.
    Lancaster, Craig M.
    Jones, Phillip
    Smith, Ryan L.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2011, 81 (05): : 1458 - 1464
  • [32] Analytical model for photon peripheral dose estimation in radiotherapy treatments
    Sanchez-Nieto, B.
    El-far, R.
    Irazola, L.
    Romero-Exposito, M.
    Lagares, J. I.
    Mateo, J. C.
    Terron, J. A.
    Sanchez Doblado, F.
    [J]. BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2015, 1 (04):
  • [33] Variations in photon energy spectra of a 6 MV beam and their impact on TLD response
    Scarboro, Sarah B.
    Followill, David S.
    Howell, Rebecca M.
    Kry, Stephen F.
    [J]. MEDICAL PHYSICS, 2011, 38 (05) : 2619 - 2628
  • [34] The impact of IMRT and proton radiotherapy on secondary cancer incidence
    Schneider, Uwe
    Lomax, Antony
    Pemler, Peter
    Besserer, Juergen
    Ross, Dieter
    Lombriser, Norbert
    Kaser-Hotz, Barbara
    [J]. STRAHLENTHERAPIE UND ONKOLOGIE, 2006, 182 (11) : 647 - 652
  • [35] Concept for quantifying the dose from image guided radiotherapy
    Schneider, Uwe
    Haelg, Roger
    Besserer, Juergen
    [J]. RADIATION ONCOLOGY, 2015, 10
  • [36] Accuracy of out-of-field dose calculation of tomotherapy and cyberknife treatment planning systems: A dosimetric study
    Schneider, Uwe
    Haelg, Roger A.
    Hartmann, Matthias
    Mack, Andreas
    Storelli, Fabrizio
    Joosten, Andreas
    Moeckli, Raphael
    Besserer, Juergen
    [J]. ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2014, 24 (03): : 211 - 215
  • [37] Experimental determination of the photon-energy dependent dose-to-water response of TLD600 and TLD700 (LiF:Mg,Ti) thermoluminescence detectors
    Schwahofer, Andrea
    Feist, Harald
    Georg, Holger
    Haering, Peter
    Schlegel, Wolfgang
    [J]. ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2017, 27 (01): : 13 - 20
  • [38] SIEBERT BRL, 1995, RADIAT PROT DOSIM, V58, P177
  • [39] FETAL DOSE FROM RADIOTHERAPY WITH PHOTON BEAMS - REPORT OF AAPM-RADIATION-THERAPY-COMMITTEE TASK GROUP NO-36
    STOVALL, M
    BALCKWELL, CR
    CUNDIFF, J
    NOVACK, DH
    PALTA, JR
    WAGNER, LK
    WEBSTER, EW
    SHALEK, RJ
    [J]. MEDICAL PHYSICS, 1995, 22 (01) : 63 - 82
  • [40] The effect of photon energy on intensity-modulated radiation therapy (IMRT) plans for prostate cancer
    Sung, Wonmo
    Park, Jong Min
    Choi, Chang Heon
    Ha, Sung Whan
    Ye, Sung-Joon
    [J]. RADIATION ONCOLOGY JOURNAL, 2012, 30 (01): : 27 - 35