Red-shifted solitons for coherent anti-Stokes Raman scattering microspectroscopy in a polarization-maintaining photonic crystal fiber

被引:1
|
作者
Yuan, Jinhui [1 ,2 ]
Sang, Xinzhu [1 ]
Wu, Qiang [1 ,3 ]
Zhou, Guiyao [4 ]
Li, Feng [2 ]
Yu, Chongxiu [1 ]
Wang, Kuiru [1 ]
Yan, Binbin [1 ]
Han, Ying [4 ]
Tam, Hwa Yaw [2 ]
Wai, Ping-Kong Alexander [2 ]
机构
[1] Beijing Univ Posts & Telecommun, State Key Lab Informat Photon & Opt Commun, Beijing 100876, Peoples R China
[2] Hong Kong Polytech Univ, Photon Res Ctr, Dept Elect & Informat Engn, Kowloon 999077, Hong Kong, Peoples R China
[3] Northumbria Univ, Dept Phys & Elect Engn, Newcastle Upon Tyne NE1 8ST, Tyne & Wear, England
[4] S China Normal Univ, Guangdong Prov Lab Nanophoton Funct Mat & Devices, Guangzhou 510006, Guangdong, Peoples R China
基金
中国国家自然科学基金; 北京市自然科学基金;
关键词
polarization-maintaining photonic crystal fiber; red-shifted solitons; coherent anti-Stokes Raman scattering microspectroscopy; MICROSTRUCTURED OPTICAL FIBERS; SUPERCONTINUUM GENERATION; MULTIPOLE METHOD; LIGHT-SOURCE; MICROSCOPY; LASER; DISPERSION;
D O I
10.1117/1.OE.54.5.056107
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
An alternative light source for coherent anti-Stokes Raman scattering (CARS) microspectroscopy based on red-shifted solitons in a polarization-maintaining photonic crystal fiber (PM-PCF) is experimentally demonstrated. By coupling femtosecond pulses into the anomalous dispersion region of the fundamental mode of a PM-PCF along the slow and fast axes, the red-shifted solitons generated can be used as the Stokes beams when the pump pulses are chosen as the pump beams. Through the process of red-shift, the frequency differences of the pump-Stokes beams are tunable in the ranges of 0 to 4068 cm(-1) and 0 to 4594 cm(-1), respectively. Moreover, because of the well maintained polarization states of the pump and Stokes beams and the high output powers of the solitons, CARS microspectroscopy using the proposed source will have a high signal-tonoise ratio and short data acquisition time. CARS microspectroscopy based on the proposed all-fiber light source can be used for studying a wide range of vibrational Raman spectra. (C) 2015 Society of Photo-Optical Instrumentation Engineers (SPIE)
引用
收藏
页数:5
相关论文
共 50 条
  • [31] Optimized continuum from a photonic crystal fiber for broadband time-resolved coherent anti-Stokes Raman scattering
    Lee, Young Jong
    Parekh, Sapun H.
    Kim, Yeon Ho
    Cicerone, Marcus T.
    OPTICS EXPRESS, 2010, 18 (05): : 4371 - 4379
  • [32] Time-resolved coherent anti-Stokes Raman scattering with a femtosecond soliton output of a photonic-crystal fiber
    Sidorov-Biryukov, Dmitrii A.
    Serebryannikov, Evgenii E.
    Zheltikov, Aleksei M.
    OPTICS LETTERS, 2006, 31 (15) : 2323 - 2325
  • [33] Clinical coherent anti-Stokes Raman scattering and multiphoton tomography of human skin with a femtosecond laser and photonic crystal fiber
    Breunig, Hans Georg
    Weinigel, Martin
    Bueckle, Rainer
    Kellner-Hoefer, Marcel
    Lademann, Juergen
    Darvin, Maxim E.
    Sterry, Wolfram
    Koenig, Karsten
    LASER PHYSICS LETTERS, 2013, 10 (02)
  • [34] Broadband coherent anti-Stokes Raman scattering spectroscopy using soliton pulse trains from a photonic crystal fiber
    Tada, K.
    Karasawa, N.
    OPTICS COMMUNICATIONS, 2009, 282 (19) : 3948 - 3952
  • [35] Single-Source Interferometric Multiplex Coherent Anti-Stokes Raman Scattering with a Photonic Crystal Fiber Light Source
    Camp, Charles H., Jr.
    Eftekhar, Ali A.
    Adibi, Ali
    2008 CONFERENCE ON LASERS AND ELECTRO-OPTICS & QUANTUM ELECTRONICS AND LASER SCIENCE CONFERENCE, VOLS 1-9, 2008, : 1005 - 1006
  • [36] Polarization-resolved coherent anti-Stokes Raman scattering microscopy
    Munhoz, Fabiana
    Brustlein, Sophie
    Brasselet, Sophie
    Rigneault, Herve
    MULTIPHOTON MICROSCOPY IN THE BIOMEDICAL SCIENCES X, 2010, 7569
  • [37] Polarization coherent anti-stokes Raman scattering using noisy light
    Weisel, Lindsay R.
    Ta, Thao
    Booth, Eric C.
    Ulness, Darin J.
    JOURNAL OF RAMAN SPECTROSCOPY, 2007, 38 (01) : 11 - 20
  • [38] Quantum squeezing effects of radiation in Stokes and anti-Stokes modes in coherent anti-Stokes Raman scattering and coherent anti-Stokes hyper-Raman scattering
    Giri, DK
    Gupta, PS
    JOURNAL OF MODERN OPTICS, 2004, 51 (11) : 1705 - 1715
  • [39] Fiber bundle based probe with polarization for coherent anti-Stokes Raman scattering microendoscopy imaging
    Liu, Zhengfan
    Wang, Zhiyong
    Wang, Xi
    Xu, Xiaoyun
    Chen, Xu
    Cheng, Jie
    Li, Xiaoyan
    Chen, Shufen
    Xin, Jianguo
    Wong, Stephen T. C.
    MULTIPHOTON MICROSCOPY IN THE BIOMEDICAL SCIENCES XIII, 2013, 8588
  • [40] Rapid diagnosis of breast cancer cell with coherent anti-Stokes raman scattering microspectroscopy
    Lee, Jang Hyuk
    Yoon, Ally
    Shin, Sang-Mo
    Oh, Myoung-Kyu
    Ko, Do-Kyeong
    2012 CONFERENCE ON LASERS AND ELECTRO-OPTICS (CLEO), 2012,