Red-shifted solitons for coherent anti-Stokes Raman scattering microspectroscopy in a polarization-maintaining photonic crystal fiber

被引:1
|
作者
Yuan, Jinhui [1 ,2 ]
Sang, Xinzhu [1 ]
Wu, Qiang [1 ,3 ]
Zhou, Guiyao [4 ]
Li, Feng [2 ]
Yu, Chongxiu [1 ]
Wang, Kuiru [1 ]
Yan, Binbin [1 ]
Han, Ying [4 ]
Tam, Hwa Yaw [2 ]
Wai, Ping-Kong Alexander [2 ]
机构
[1] Beijing Univ Posts & Telecommun, State Key Lab Informat Photon & Opt Commun, Beijing 100876, Peoples R China
[2] Hong Kong Polytech Univ, Photon Res Ctr, Dept Elect & Informat Engn, Kowloon 999077, Hong Kong, Peoples R China
[3] Northumbria Univ, Dept Phys & Elect Engn, Newcastle Upon Tyne NE1 8ST, Tyne & Wear, England
[4] S China Normal Univ, Guangdong Prov Lab Nanophoton Funct Mat & Devices, Guangzhou 510006, Guangdong, Peoples R China
基金
中国国家自然科学基金; 北京市自然科学基金;
关键词
polarization-maintaining photonic crystal fiber; red-shifted solitons; coherent anti-Stokes Raman scattering microspectroscopy; MICROSTRUCTURED OPTICAL FIBERS; SUPERCONTINUUM GENERATION; MULTIPOLE METHOD; LIGHT-SOURCE; MICROSCOPY; LASER; DISPERSION;
D O I
10.1117/1.OE.54.5.056107
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
An alternative light source for coherent anti-Stokes Raman scattering (CARS) microspectroscopy based on red-shifted solitons in a polarization-maintaining photonic crystal fiber (PM-PCF) is experimentally demonstrated. By coupling femtosecond pulses into the anomalous dispersion region of the fundamental mode of a PM-PCF along the slow and fast axes, the red-shifted solitons generated can be used as the Stokes beams when the pump pulses are chosen as the pump beams. Through the process of red-shift, the frequency differences of the pump-Stokes beams are tunable in the ranges of 0 to 4068 cm(-1) and 0 to 4594 cm(-1), respectively. Moreover, because of the well maintained polarization states of the pump and Stokes beams and the high output powers of the solitons, CARS microspectroscopy using the proposed source will have a high signal-tonoise ratio and short data acquisition time. CARS microspectroscopy based on the proposed all-fiber light source can be used for studying a wide range of vibrational Raman spectra. (C) 2015 Society of Photo-Optical Instrumentation Engineers (SPIE)
引用
收藏
页数:5
相关论文
共 50 条
  • [1] COHERENT ANTI-STOKES RAMAN SCATTERING MICROSCOPY BY DISPERSIVE WAVE GENERATIONS IN A POLARIZATION MAINTAINING PHOTONIC CRYSTAL FIBER
    Yuan, Jinhui
    Zhou, Guiyao
    Liu, Hongzhan
    Xia, Changming
    Sang, Xinzhu
    Wu, Qiang
    Yu, Chongxiu
    Wang, Kuiru
    Yan, Binbin
    Han, Ying
    Farrell, Gerald
    Hou, Lantian
    PROGRESS IN ELECTROMAGNETICS RESEARCH-PIER, 2013, 141 : 659 - 670
  • [2] Coherent Anti-Stokes Raman Scattering Microscopy Based on Polarization Maintaining Photonics Crystal Fiber
    Lee, Jae Hwi
    Park, Soongho
    Shin, Jun Geun
    Kim, Hyunmin
    Moon, DaeWon
    Lee, Seungmin
    Park, Hojin
    Lee, Byeong Ha
    2017 25TH INTERNATIONAL CONFERENCE ON OPTICAL FIBER SENSORS (OFS), 2017, 10323
  • [3] Coherent anti-stokes Raman scattering microspectroscopy of silicon components with a photonic-crystal fiber frequency shifter
    Mitrokhin, V. P.
    Fedotov, A. B.
    Ivanov, A. A.
    Alfimov, M. V.
    Zheltikov, A. M.
    OPTICS LETTERS, 2007, 32 (23) : 3471 - 3473
  • [4] Optimization of coherent anti-Stokes Raman scattering microscopy using photonic crystal fiber
    Murugkar, Sangeeta
    Logvin, Yury
    Brideau, Craig
    Ridsdale, Andrew
    Stys, Peter
    Anis, Hanan
    PHOTONICS NORTH 2007, PTS 1 AND 2, 2007, 6796
  • [5] Blue-shifted dispersive wave generation by the diffraction-arrested solitons for coherent anti-Stokes Raman scattering microscopy in a photonic crystal fiber
    Yuan, Jinhui
    Sang, Xinzhu
    Zhou, Guiyao
    Liu, Hongzhan
    Xia, Changming
    Wu, Qiang
    Yu, Chongxiu
    Wang, Kuiru
    Yan, Binbin
    Han, Ying
    Farrell, Gerald
    Hou, Lantian
    OPTICS COMMUNICATIONS, 2014, 320 : 73 - 76
  • [6] Frequency-shifted megawatt soliton output of a hollow photonic-crystal fiber for time-resolved coherent anti-Stokes Raman scattering microspectroscopy
    Ivanov, A. A.
    Podshivalov, A. A.
    Zheltikov, A. M.
    OPTICS LETTERS, 2006, 31 (22) : 3318 - 3320
  • [7] Raman and coherent anti-Stokes Raman scattering microspectroscopy for biomedical applications
    Krafft, Christoph
    Dietzek, Benjamin
    Schmitt, Michael
    Popp, Juergen
    JOURNAL OF BIOMEDICAL OPTICS, 2012, 17 (04)
  • [8] Analytical capabilities of coherent anti-Stokes Raman scattering microspectroscopy
    Arora, Rajan
    Petrov, Georgi I.
    Yakovlev, Vladislav V.
    JOURNAL OF MODERN OPTICS, 2008, 55 (19-20) : 3237 - 3254
  • [9] Intracellular coherent anti-Stokes Raman scattering (CARS) microspectroscopy
    Kovalev, Alexander
    Patincharath, Nandakumar
    Volkmer, Andreas
    BIOPHYSICAL JOURNAL, 2007, : 196A - 196A
  • [10] Coherent anti-Stokes Raman scattering imaging with a laser source delivered by a photonic crystal fiber
    Wang, Haifeng
    Huff, Terry B.
    Cheng, Ji-Xin
    OPTICS LETTERS, 2006, 31 (10) : 1417 - 1419