Red-shifted solitons for coherent anti-Stokes Raman scattering microspectroscopy in a polarization-maintaining photonic crystal fiber

被引:1
作者
Yuan, Jinhui [1 ,2 ]
Sang, Xinzhu [1 ]
Wu, Qiang [1 ,3 ]
Zhou, Guiyao [4 ]
Li, Feng [2 ]
Yu, Chongxiu [1 ]
Wang, Kuiru [1 ]
Yan, Binbin [1 ]
Han, Ying [4 ]
Tam, Hwa Yaw [2 ]
Wai, Ping-Kong Alexander [2 ]
机构
[1] Beijing Univ Posts & Telecommun, State Key Lab Informat Photon & Opt Commun, Beijing 100876, Peoples R China
[2] Hong Kong Polytech Univ, Photon Res Ctr, Dept Elect & Informat Engn, Kowloon 999077, Hong Kong, Peoples R China
[3] Northumbria Univ, Dept Phys & Elect Engn, Newcastle Upon Tyne NE1 8ST, Tyne & Wear, England
[4] S China Normal Univ, Guangdong Prov Lab Nanophoton Funct Mat & Devices, Guangzhou 510006, Guangdong, Peoples R China
基金
中国国家自然科学基金; 北京市自然科学基金;
关键词
polarization-maintaining photonic crystal fiber; red-shifted solitons; coherent anti-Stokes Raman scattering microspectroscopy; MICROSTRUCTURED OPTICAL FIBERS; SUPERCONTINUUM GENERATION; MULTIPOLE METHOD; LIGHT-SOURCE; MICROSCOPY; LASER; DISPERSION;
D O I
10.1117/1.OE.54.5.056107
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
An alternative light source for coherent anti-Stokes Raman scattering (CARS) microspectroscopy based on red-shifted solitons in a polarization-maintaining photonic crystal fiber (PM-PCF) is experimentally demonstrated. By coupling femtosecond pulses into the anomalous dispersion region of the fundamental mode of a PM-PCF along the slow and fast axes, the red-shifted solitons generated can be used as the Stokes beams when the pump pulses are chosen as the pump beams. Through the process of red-shift, the frequency differences of the pump-Stokes beams are tunable in the ranges of 0 to 4068 cm(-1) and 0 to 4594 cm(-1), respectively. Moreover, because of the well maintained polarization states of the pump and Stokes beams and the high output powers of the solitons, CARS microspectroscopy using the proposed source will have a high signal-tonoise ratio and short data acquisition time. CARS microspectroscopy based on the proposed all-fiber light source can be used for studying a wide range of vibrational Raman spectra. (C) 2015 Society of Photo-Optical Instrumentation Engineers (SPIE)
引用
收藏
页数:5
相关论文
共 28 条
[1]   Tunable light source for coherent anti-Stokes Raman scattering microspectroscopy based on the soliton self-frequency shift [J].
Andresen, ER ;
Birkedal, V ;
Thogersen, J ;
Keiding, SR .
OPTICS LETTERS, 2006, 31 (09) :1328-1330
[2]   Broadband multiplex coherent anti-Stokes Raman scattering microscopy employing photonic-crystal fibers [J].
Andresen, ER ;
Paulsen, HN ;
Birkedal, V ;
Thogersen, J ;
Keiding, SR .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA B-OPTICAL PHYSICS, 2005, 22 (09) :1934-1938
[3]   Fiber laser-based light source for coherent anti-Stokes Raman scattering microspectroscopy [J].
Andresen, Esben Ravn ;
Nielsen, Carsten Krogh ;
Thogersen, Jan ;
Keiding, Soren Rud .
OPTICS EXPRESS, 2007, 15 (08) :4848-4856
[4]   Stimulated Raman scattering microscopy by spectral focusing and fiber-generated soliton as Stokes pulse [J].
Andresen, Esben Ravn ;
Berto, Pascal ;
Rigneault, Herve .
OPTICS LETTERS, 2011, 36 (13) :2387-2389
[5]   All-fiber laser source for CARS microscopy based on fiber optical parametric frequency conversion [J].
Baumgartl, Martin ;
Chemnitz, Mario ;
Jauregui, Cesar ;
Meyer, Tobias ;
Dietzek, Benjamin ;
Popp, Juergen ;
Limpert, Jens ;
Tuennermann, Andreas .
OPTICS EXPRESS, 2012, 20 (04) :4484-4493
[6]   Polarization coherent anti-Stokes Raman scattering microscopy [J].
Cheng, JX ;
Book, LD ;
Xie, XS .
OPTICS LETTERS, 2001, 26 (17) :1341-1343
[7]   Supercontinuum generation in photonic crystal fiber [J].
Dudley, John M. ;
Genty, Goery ;
Coen, Stephane .
REVIEWS OF MODERN PHYSICS, 2006, 78 (04) :1135-1184
[8]   SCANNING COHERENT ANTI-STOKES RAMAN MICROSCOPE [J].
DUNCAN, MD ;
REINTJES, J ;
MANUCCIA, TJ .
OPTICS LETTERS, 1982, 7 (08) :350-352
[9]   Coherent anti-Stokes Raman scattering spectral interferometry:: determination of the real and imaginary components of nonlinear susceptibility χ(3) for vibrational microscopy [J].
Evans, CL ;
Potma, EO ;
Xie, XSN .
OPTICS LETTERS, 2004, 29 (24) :2923-2925
[10]   Label-Free Biomedical Imaging with High Sensitivity by Stimulated Raman Scattering Microscopy [J].
Freudiger, Christian W. ;
Min, Wei ;
Saar, Brian G. ;
Lu, Sijia ;
Holtom, Gary R. ;
He, Chengwei ;
Tsai, Jason C. ;
Kang, Jing X. ;
Xie, X. Sunney .
SCIENCE, 2008, 322 (5909) :1857-1861