RADIANT CEILING COOLING CHARACTERISTICS AND THERMAL COMFORT FOR OFFICE ROOMS

被引:5
|
作者
Terzioglu, Ibrahim Yasin
Turgut, Oguz
机构
[1] Gazi Univ, Dept Mech Engn, Ankara, Turkey
[2] Gazi Univ, Clean Energy Res & Applicat Ctr TEMENAR, Ankara, Turkey
关键词
ceiling cooling; radiant cooling; CFD; cooling application; condensation; thermal comfort; HEAT-TRANSFER; SYSTEMS; ENERGY; PERFORMANCE; PANEL; IMPROVEMENT; POWER;
D O I
10.1615/HeatTransRes.2020033104
中图分类号
O414.1 [热力学];
学科分类号
摘要
Radiant ceiling cooling systems are used for both thermal comfort condition and energy saving due to the higher supply temperatures with respect to the classical air ventilation systems. In this paper, the characteristics of radiant ceiling cooling system and thermal comfort conditions have been investigated numerically. A three-dimensional mathematical model is simulated using ANSYS Fluent 17.0. Heat transfer in the concrete panel and typical office room is studied. The examined parameters are the pipe configuration type, supply velocity, and supply temperature. Thermal comfort conditions are examined for an office room with one person and two persons. Numerical results are validated with the literature results, and the results are found to be consistent with each other. The results show that a labyrinth pipe configuration gives better comfort conditions than a spiral pipe configuration. Proper values of supply velocity and temperature for the labyrinth pipe configuration are found as 0.49 m/s and 14 degrees C, respectively.
引用
收藏
页码:909 / 923
页数:15
相关论文
共 50 条
  • [1] Experimental Evaluation of the Thermal Comfort in an Occupied Office under Transient Conditions using a Hydronic Radiant Ceiling Cooling System
    Ruiz de Adana, Manuel
    Olmedo, Ines
    Peci, Fernando
    ASHRAE TRANSACTIONS 2014, VOL 120, PT 1, 2014, 120
  • [2] ANALYSIS OF THE BEHAVIOR OF THE COOLING CEILING IN AN OFFICE ROOM WITH A VIEW OF THERMAL COMFORT
    Sikula, O.
    Hirs, J.
    23RD IIR INTERNATIONAL CONGRESS OF REFRIGERATION, 2011, 23 : 3808 - +
  • [3] An experimental study of thermal performance of the radiant ceiling cooling in office building in Thailand
    Aryal, Ashmin
    Chaiwiwatworakul, Pipat
    Chirarattananon, Surapong
    ENERGY AND BUILDINGS, 2023, 283
  • [4] Occupant's thermal comfort in a radiant ceiling cooling room with hot wall surface
    Wu, Xiaozhou
    Liu, Genglin
    Tian, Zhen
    Gao, Jie
    INDOOR AND BUILT ENVIRONMENT, 2023, 32 (04) : 699 - 718
  • [5] A field study of occupant thermal comfort with radiant ceiling cooling and overhead air distribution system
    Tian, Zhen
    Yang, Liu
    Wu, Xiaozhou
    Guan, Zhenzhong
    ENERGY AND BUILDINGS, 2020, 223
  • [6] Numerical prediction of thermal comfort and condensation risk in a ventilated office, equipped with a cooling ceiling
    Teodosiu, Catalin
    Ilie, Viorel
    Teodosiu, Raluca
    EENVIRO-YRC 2015 - BUCHAREST, 2016, 85 : 550 - 558
  • [7] Thermal comfort and ventilation effectiveness in an office room with radiant floor cooling and displacement ventilation
    Krajcik, Michal
    Tomasi, Roberta
    Simone, Angela
    Olesen, Bjarne W.
    SCIENCE AND TECHNOLOGY FOR THE BUILT ENVIRONMENT, 2016, 22 (03) : 317 - 327
  • [8] Radiant ceiling cooling
    Dieckmann, J
    Roth, KW
    Brodrick, J
    ASHRAE JOURNAL, 2004, 46 (06) : 42 - 43
  • [9] Effect of humidity and small air movement on thermal comfort under a radiant cooling ceiling by subjective experiments
    Kitagawa, K
    Komoda, E
    Hayano, H
    Tanabe, S
    ENERGY AND BUILDINGS, 1999, 30 (02) : 185 - 193
  • [10] Experimental Study on Cooling Characteristics of Concrete Ceiling Radiant Cooling Panel
    Su, Lin
    Li, Nianping
    Zhang, Xuhan
    9TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATION AND AIR CONDITIONING (ISHVAC) JOINT WITH THE 3RD INTERNATIONAL CONFERENCE ON BUILDING ENERGY AND ENVIRONMENT (COBEE), 2015, 121 : 2168 - 2175