RADIANT CEILING COOLING CHARACTERISTICS AND THERMAL COMFORT FOR OFFICE ROOMS

被引:5
作者
Terzioglu, Ibrahim Yasin
Turgut, Oguz
机构
[1] Gazi Univ, Dept Mech Engn, Ankara, Turkey
[2] Gazi Univ, Clean Energy Res & Applicat Ctr TEMENAR, Ankara, Turkey
关键词
ceiling cooling; radiant cooling; CFD; cooling application; condensation; thermal comfort; HEAT-TRANSFER; SYSTEMS; ENERGY; PERFORMANCE; PANEL; IMPROVEMENT; POWER;
D O I
10.1615/HeatTransRes.2020033104
中图分类号
O414.1 [热力学];
学科分类号
摘要
Radiant ceiling cooling systems are used for both thermal comfort condition and energy saving due to the higher supply temperatures with respect to the classical air ventilation systems. In this paper, the characteristics of radiant ceiling cooling system and thermal comfort conditions have been investigated numerically. A three-dimensional mathematical model is simulated using ANSYS Fluent 17.0. Heat transfer in the concrete panel and typical office room is studied. The examined parameters are the pipe configuration type, supply velocity, and supply temperature. Thermal comfort conditions are examined for an office room with one person and two persons. Numerical results are validated with the literature results, and the results are found to be consistent with each other. The results show that a labyrinth pipe configuration gives better comfort conditions than a spiral pipe configuration. Proper values of supply velocity and temperature for the labyrinth pipe configuration are found as 0.49 m/s and 14 degrees C, respectively.
引用
收藏
页码:909 / 923
页数:15
相关论文
共 36 条
[1]  
[Anonymous], 2015, Ph. D. Dissertation
[2]  
*ANSYS, 2016, ANSYS FLUENT 17 0 TH
[3]   Evaluation of thermal comfort using combined CFD and experimentation study in a test room equipped with a cooling ceiling [J].
Catalina, Tiberiu ;
Virgone, Joseph ;
Kuznik, Frederic .
BUILDING AND ENVIRONMENT, 2009, 44 (08) :1740-1750
[4]   Experimental comparison of thermal comfort during cooling with a fan coil system and radiant floor system at varying space heights [J].
Cen, Chao ;
Jia, Yihong ;
Liu, Kuixing ;
Geng, Ruoxi .
BUILDING AND ENVIRONMENT, 2018, 141 :71-79
[5]   Performance improvement of a split air conditioner by using an energy saving device [J].
Chen, Wei-Han ;
Mo, Huai-En ;
Teng, Tun-Ping .
ENERGY AND BUILDINGS, 2018, 174 :380-387
[6]   Evaluation of cooling ceiling and mechanical ventilation systems on thermal comfort using CFD study in an office for subtropical region [J].
Chiang, Wei-Hwa ;
Wang, Chia-Ying ;
Huang, Jian-Sheng .
BUILDING AND ENVIRONMENT, 2012, 48 :113-127
[7]   COMPUTATION OF RADIANT-HEAT TRANSFER ON A NONORTHOGONAL MESH USING THE FINITE-VOLUME METHOD [J].
CHUI, EH ;
RAITHBY, GD .
NUMERICAL HEAT TRANSFER PART B-FUNDAMENTALS, 1993, 23 (03) :269-288
[8]  
Dogan V., 2012, PLANT ENG, V130, P41
[9]  
Fanger PO., 1970, THERMAL COMFORT
[10]   Experimental analysis and modeling of hydronic radiant ceiling panels using transient-state analysis [J].
Fonseca, Nestor .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2011, 34 (04) :958-967